background image

MAILING ADDRESS 

PHONE 

FAX 

E-MAIL 

 
UL. ODLEWNIKÓW 18 
PL-44-100 GLIWICE 
POLAND 

+48-32 237-26-88 

+48-32 231-81-19 

[email protected] 

Edition 09.2 

 
 
 

 
 
 
 
 
 
 
 

S

S

e

e

n

n

s

s

o

o

D

D

a

a

t

t

a

a

 

 

5

5

5

5

0

0

0

0

 

 

 

 

 

 

O

O

p

p

e

e

r

r

a

a

t

t

o

o

r

r

s

s

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SensoData 5500

Page 1: ...ONE FAX E MAIL UL ODLEWNIK W 18 PL 44 100 GLIWICE POLAND 48 32 237 26 88 48 32 231 81 19 OFFICE SENSOR ELECTRONIC PL Edition 09 2 S Se en ns so oD Da at ta a 5 55 50 00 0 O Op pe er ra at to or r s s...

Page 2: ...anemometer transducers B configuration with SensoTCMod 5507 module of thermal comfort and two SensoAnemo 5100SF anemometer transducers C configuration with SensoHygBar 5303 pressure and humidity tran...

Page 3: ...nabling to attach external transducers or modules In the photo is presented general view with sockets and indicators A USB socket to connect to a computer B socket depending on the version to connect...

Page 4: ...of two SensoTCMod 5503 measuring modules enables the simultaneous measurement at three heights The SensoData 5500 datalogger has two connectors see photo n the right to connecting the measuring modul...

Page 5: ...supports Additional RTD sensor may be connected to the socket on the lateral wall of the cylinder It can be used for supplementary temperature measurement eg floor surface temperature or air inlet tem...

Page 6: ...by the shielding tube 3 2 Connect the air speed probe to measurement modules Loosen the clamp screw 5 and move the shielding tube 3 with the openwork basket 4 into the bottom uncovering the sensors 1...

Page 7: ...probe SF enables measurements of jet ventilation and effectiveness of the ventilation in rooms Includes the spherical omnidirectional air speed 1 and compensation temperature 2 sensors Both the senso...

Page 8: ...k basket 4 should be put on and put out only then when the speed sensor 1 is covered and secured by the shielding tube 3 3 Use the openwork basket 4 if you are not sure of the safety of the sensors du...

Page 9: ...fter scanning a screen appears with a selection environment only for thermal comfort module and next a screen with a configuration with a list of connected transducers After pressing the ESC key or au...

Page 10: ...the measuring module in the same way as described above Note 1 SensoTCMod module contains three Anemo Thermo HygroBaro or two Anemo Thermo measuring transducers which are identified separately by the...

Page 11: ...in single mode AUT Mode indicator Indicates the selected mode In automatic mode indicator AUT is displayed and in single mode indicator SIN is displayed BAR Indicator of anemometer compensation with r...

Page 12: ...de the time counter is flashing Beginning and the end of the measurement is indicated by buzzer The average value on the display are updated every 2s from the beginning of measurement After stopping t...

Page 13: ...t a 2 3 5 t g c 2 3 8 t n w 2 3 1 t s 2 4 1 W B G T i n 2 3 4 W B G T o u t 2 3 4 AUT BAR O C O C O C O C T H E R M A L C O M F O R T 00 08 O C O C ta air temperature tgc globe temperature tnw natura...

Page 14: ...key or from the main menu when you select SETTINGS Z M 1 3 5 8 4 9 kJ kg 2 1 5 hPa 1 0 6 7 g kg 1 1 4 kg m3 T H E R M A L C O M F O R T BAR 00 08 O C Dew pa AUT i x r Dew dewpoint temperature PMV pre...

Page 15: ...ronment appears the following screen H 2 8 4 7 W m2 Emax 3 0 7 4 W m2 Wreq 0 8 5 6 1 5 1 W m2 SWreq Ereq AUT BAR Icl M Ar ADu 00 08 T H E R M A L C O M F O R T Ereq required evaporation rate Emax maxi...

Page 16: ...on in the case of the presence of a pressure sensor option 5500 SensoData Anemo B the following screen is displayed Then device automatically compensates pressure influence on the air speed In order t...

Page 17: ...O OF F M ME EA AS SU UR RI IN NG G R RE ES SU UL LT TS S Recording results in the automatic mode Pressing the Rec key in automatic mode starts recording results The results are saved in the internal m...

Page 18: ...O R T A N E M O M O D U L E 1 T H E R M O M O D U L E 1 H Y G R O B A R O M O D U L E 1 OK While displaying the screen with the configuration it is possible to select one of items by pressing vertica...

Page 19: ...B u z z e r B a c k l i g h t D i s p l a y c o n t r a s t W i r e l e s s c o n n E C O M o d e M A I N M E N U C o n t ESC OK Memory delete select the appropriate item by pressing the vertical cur...

Page 20: ...nsoData The program can be found on the supplied CD or you can download it from the website www sensor electronic pl In order to install the program run the Setup exe file in the folder SensoData Tran...

Page 21: ...ansmitter can cause a loss of communication between the device and the measuring modules transducers Replace the batteries if the blue led is not blink 3 Radio signal does not generate additional meas...

Page 22: ...sponds to globe with a diameter 15 cm Operative Temperature O C r c r r a c o h h t h t h t where 25 0 6 0 38 2 1 7 8 1 2 5 5 3 max_ a sk ar ar ar ar c t t v for v or v for v of h 3 8 273 2 10 9996 21...

Page 23: ...1 req req req W E SW if 0 max E then 2 req W req req E SW 2 if 0 req E then 0 req W 0 req SW if 1 req W then req req E SW 2 Adjusted Dry Bulb Temperature O C r a adb t A At t 1 where A 0 5 for vm 0 2...

Page 24: ...sition and connect socket A with SensoBeeUSB receiver by the cable If the power supply is plugged into the mains socket the PS diode lights up The RF diode is blinking when the RF module is turned on...

Page 25: ...pacity due to reduced efficiency when converting from battery voltage 3 6 V to the output voltage 5V theoretical capacity of batteries is 13000mAh Notes 1 Turn off the device by disconnecting the powe...

Page 26: ...n the photos below Attention should be paid to the pipes D1 D3 turn in the order corresponding to the incisions ie D1 pipe single to the D2 dual and D2 to D3 pipe triple D1 pipe should be inserted to...

Page 27: ...er 1 18 8 G GU UA AR RA AN NT TE EE E A AN ND D R RE EP PA AI IR RS S Manufacturer guarantees the correct operation of the devices The guarantee period is 24 months beginning from the date of sale All...

Page 28: ...SensoData 5500 28 Operator s Manual A AR RR RA AN NG GE EM ME EN NT T O OF F T TH HE E E EQ QU UI IP PM ME EN NT T I IN N T TR RA AN NS SP PO OR RT T C CA AS SE E...

Reviews: