background image

SCT-1047  Ver. 1.0

1

CAMERA CONTROL CODE TRANSLATOR

PELCO RS-422 to JAVELIN RS-232  Ver. 1.0

SCT-1047

www.sennetech.net

Sennetech, Inc.  6455 W. Bath Rd. Perry, MI 48872  U.S.A.   Ph (517) 675-1150   Fax (517) 675-1151

Summary of Contents for SCT-1047

Page 1: ...SCT 1047 Ver 1 0 1 CAMERACONTROLCODE TRANSLATOR PELCO RS 422 to JAVELIN RS 232 Ver 1 0 SCT 1047 www sennetech net Sennetech Inc 6455 W Bath Rd Perry MI 48872 U S A Ph 517 675 1150 Fax 517 675 1151 ...

Page 2: ...2 ...

Page 3: ...lin cameras from Pelco controllers It receives Pelco RS 422 commands and transmits the appropri ate commands in Javelin RS 232 format 9600 baud N81 There are four independent Javelin outputs The unit s operating mode is set with an internal configuration switch It can be configured to accept either Pelco P or D code The output can be Javelin code compatible with either JO208 ACUs or JO308ACUs Inpu...

Page 4: ...ON P CODE OFF D CODE Set to match the type of code from the Pelco control system When setting up Pelco com ports to work with a code translator configure the port the same as it would be for a Pelcodome SW1 7 P CODE BAUD RATE ON 9600 BAUD OFF 4800 BAUD This switch is ignored if SW1 7 is OFF SW1 5 JAVELIN CODETYPE ON JO208 OFF JO308 SETTING THE SWITCHES CONFIGURATION SWITCH U11 U10 U9 U8 U13 U6 U3 ...

Page 5: ...Com pin 5 If connecting to a Javelin Remote Receiver for control of JO208 ACUs via a JO107 multiplexer SCT 1047 RCVR Tx pin 2 Com pin 7 Power indicator Pelco receive indicator Javelin transmit indicator FRONT PANEL REARPANEL INSTALLATION Power Tx Rx CODE TRANSLATOR PELCO RS 422 IN POWER 9V to 15V AC or DC JAVELIN RS 232 OUTPUTS S Rx Tx Com Rx Tx Com Rx Tx Com Rx Tx Com ...

Page 6: ...6 ...

Page 7: ...elco Program Preset 61 to 68 commands set the Javelin camera movement limits 61 Set Set Right Limit 62 Set Clear Right Limit 63 Set Set Down Limit 64 Set Clear Down Limit 65 Set Set Left Limit 66 Set Clear Left Limit 67 Set Set Up Limit 68 Set Clear Up Limit There are six Javelin F or R commands that can be used to control relays Pelco Aux commands are converted to these commands 1 On R1 2 On R2 3...

Page 8: ...8 January 2006 SCT 1047 Ver 1 0 ...