background image

MI00597-0-EN

INSTALLATION MANUAL

1/4

INSTALLATION MANUAL

SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel.  +39.049.8705359  -  Fax +39.049.8706287

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available via QR-CODE shown on page 1.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to 

electrostatic discharges. Take appropriate measures during any operation.

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at risk.

The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment. The warranty shall become null and void in the event of improper use or 

tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if 

the instructions contained in this manual are not followed.

CONTACT INFORMATION

Technical support

[email protected]

Product information

[email protected]

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.

The content of this document corresponds to the described products and technologies.

Stated data may be modified or supplemented for technical and/or sales purposes.

Z-8TC-SI

Z-8TC-SI-LAB

DOCUMENTATION

Z-8TC-SI

DOCUMENTATION

Z-8TC-SI-LAB

Summary of Contents for Z-8TC-SI

Page 1: ...s during any operation PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user s safety at risk The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment The warranty shall become null and void in the event of improper use or tampering with the module or devices suppli...

Page 2: ...15200 Baud Micro USB on the front ModBUS protocol 2400 Baud INSULATION COMMUNICATION PORTS RS485 on IDC10 connector PROTOCOL ModBUS RTU TC INPUTS No of channels 8 Type of thermocouples J K E N S R B T L individually activated and configurable in pairs MODULE LAYOUT SIGNALS VIA LED ON FRONT PANEL 17 5 mm Dimensions 17 5 x 102 5 x 111 mm Weight 100 g Container PA6 black 111 mm 102 5 mm LED STATUS LE...

Page 3: ...1 stop bit FACTORY SETTINGS 1 2 3 4 5 6 7 8 KEY ON OFF SPAN mV 150mV IMPEDANCE 4MΩ ADC 24 bit TEMPERATURE DRIFT 100ppm K COLD JUNCTION ERROR 1 C TEST CURRENT 100nA CMRR 70dB 100ms DMRR 60 dB SUPPORTED INPUT SPECIFICATIONS SENSOR ACCURACY AT 23 C SOLUTION MEASURING RANGE STANDARD J 0 03 0 2 C 0 5µV 0 01 C 0 C 210 1200 C EN 60584 1 1997 K 0 03 0 2 C 0 5µV 0 02 C 0 C 200 1372 C EN 60584 1 1997 R 0 03...

Page 4: ...bjects that obstruct the ventilation slots Avoid mounting modules over heat generating equipment Installation in the bottom part of the electrical panel is recommended These are open type devices intended for installation in a final casing panel that offers mechanical protection and protection against the spread of fire 1 Install the modules in the DIN rail 120 max 2 Connect the remote modules usi...