DEVICE FOR PROTECTION OF POWER LINES AND GROUND  

(Controlled noise generator through power lines and ground) 

SEL SP-44 

 
 

USER MANUAL 

 
 
 
 
 

      
 
 

 
 
 

 
 

 
 

 
 
 
 
 
 
 

 

 
 
 

2016 

 
 
 

Содержание SEL SP-44

Страница 1: ...www SELCOMSECURITY com DEVICE FOR PROTECTION OF POWER LINES AND GROUND Controlled noise generator through power lines and ground SEL SP 44 USER MANUAL 2016 ...

Страница 2: ...tors as well as ground circuits and power supply electro conductive line and engineered technical communications going beyond the controlled zone Factory settings of the device SEL SP 44 1 The minimal level of integrated noise signal is set 2 Remote turn on of the working mode is turned off 3 Password for settings _______________ 1 TECHNICAL CHARACTERISTICS Device SEL SP 44 itself is a two channel...

Страница 3: ... 220V 50 60 Hz 11 Power consumption 12 Watt 12 Dimensions and weight not more than 180х180х50 mm 1 5 kg 13 Time until failure not less than 6000 hours 14 Service life not less than 7 years when the resource is not less than 27000 hours 2 DELIVERY SET 3 PREPARATION FOR USE 3 1 Safety measures Electrical safety of the device is carried out by grounding through the grounding contact of the mains plug...

Страница 4: ...y turn on the device Connection of the wired switch is made through the RC connector on the rear surface of the device Wired switch normally open with fixation It connects to pins 1 and 2 of the RC connector To indicate the generation of a noise signal an led 3 cathode 4 anode can be connected to the same connector 3 3 2 Power connection disconnection 1 Power Supply Connection connect the device t...

Страница 5: ...igh frequency noise level setting Further by pressing the MENU OK or C buttons MENU OK to confirm the selected parameter for setting the C cancels the selected setting 2 Exiting Setting mode To exit setting mode press the C button 3 Setting the noise signal level The noise level is set separately for the low frequency LF and high frequency HF bands The initial state of the setting is selected acco...

Страница 6: ...s LEDs OUTPUT LF and OUTPUT HF on the front panel of the device are green 4 3 Turn off the operating mode Turn off operating mode 1 When you prohibit the use of remote switching factory setting by pressing and holding the C button on the front panel of the device till LCD switches off 2 When allowing the use of remote on switch toggle switch to the 0 off the LED switch is off 4 4 The order of the ...

Отзывы: