background image

MobilSwitch-Micro-C

Industrial GSM signalling and remote control module

with 2 inputs and 2 high current relay outputs

 

The

MobilSwitch-Micro-C

module is a general, industrial-grade GSM module, developed for remote

signaling and remote control. It has

2 inputs

which are activated by voltage-less contact, and it has

2

high

voltage and high current

relay outputs

. It can be programmed with its own software called "

Unified

" from

any PC or notebook. The device notifies the users via pre-configured SMS-s and voice calls, and it has an
optional acknowledging function. The relays can be triggered by user-configured SMS-s or free voice calls
for dedicated users. The relays can be configured to operate in

monostable

mode (after switching on, the

relays are turned off automatically within a time interval) or

bistable

mode. (switching the relays on and off

are performed with separate commands). It can be programmed for max.

8 phone number

s, and can be used

as a GSM remote signaling, remote controlling device, either for industrial purposes or home applications,
such as remote signaling and controlling security device. The power supply of the device has industrial input
range of

1

0V-30V DC

and draws min.

500mA

current. The carrier's SMS-s can be forwarded to the user-

configured phone number, and the device operation can be checked with its built-in signal-of-operation
function. It  has two variants: either with built-in aerial or 

RG-174

 magnetic aerial with 

SMA

 connector. 

 

1.   Operation:

The module holds its configured and
programmed data even after power-off. In
the case of carrier problems or cellular
signal loss, the device switches itself off
then on, re-connects to cellular network
and restores normal operation. The device
comes with an enclosure and carrier-
independent GSM module in DIN rail
enclosure with a small SMA connected
aerial or with  external magnetic antenna.

        

The device comes with our free

configuration software that can be down-
loaded from website:

www.seasoft.hu

Our devices  can be  configured  with any

PC-s with a single

micro-USB

cable. The

MobilSwitch-Micro-c

has a carrier-independent, industrial-grade

GSM module that can be operated with any prepaid or subscription-based

nanoSIM

cards. The low voltage

low-current variant is called 

MobilSwitch-Micro

, or 

Micro-a

 and available also with two antenna-variations.

SeaSoft  kft.

                            

www.seasoft.hu                     www.mobil-control.eu

 

                  

   T: (62) 406-405      M: (+36) 30 255 7688     F: (62) 405-969

Summary of Contents for MobilSwitch-Micro-C

Page 1: ... The power supply of the device has industrial input range of 10V 30V DC and draws min 500mA current The carrier s SMS s can be forwarded to the user configured phone number and the device operation can be checked with its built in signal of operation function It has two variants either with built in aerial or RG 174 magnetic aerial with SMA connector 1 Operation The module holds its configured an...

Page 2: ...omatically loads the default configuration parameters 8 It is advised to query the status of the device state of inputs outputs supply voltage signal strength etc to check if the device is registered to the GSM network After downloading the configuration the USB should be detached before powering the device off 9 After downloading the configuration and powering the module off it should be turned o...

Page 3: ...he maximum load of relay outputs cannot exceed 6A at 250Vac The inputs of device are equipped with noise protection however external voltage mus nt be applied to them Inputs can be triggered with small resistance and without contact bouncing contacts switches and relays The module is equipped with a standard nanoSIM holder The module can be programmed and configured with a microUSB cable 5 Device ...

Page 4: ...hone numbers should receive an SMS notification when an input has changed Each memory location has a short description located at the bottom Please fill the configuration values with care and do not use accented or special characters All telephone numbers must be given in the international telephone number format The edited configuration can be saved to a file and loaded whenever necessary The con...

Page 5: ...utton 023 SMS message when input no 1 is ON pressed 024 SMS message when input no 1 is OFF released 025 Name of 1st input Burglary system 026 SMS message when input no 2 is ON Alarm 027 SMS message when input no 2 is OFF Restore 028 Name of 1st output Siren 029 SMS command to switch ON the output no 1 Sound on 030 SMS command to switch OFF the output no 1 Sound off 031 Name of 2nd output Lamp 032 ...

Page 6: ... notifications upon input changes however it is still capable of sending response SMS s Re program memory command 022 Panic trigger where 022 memory address Panic trigger the new value of memory Read memory location command 022 Response SMS 022 Panic trigger 7 Miscellaneous and other information a The device is operational with any nano SIM card b The received SMS s from the carrier and unknown nu...

Page 7: ...uts 6 V max Mean consuption 24hours 70 mA Aerial connector SMA Max conpuption 192 mA Ambient temperature 30 70 C Vertical size of enclosure 90 mm Vertical size with aerial 119 mm Vertical size of magnetic aerial 110 mm Horizontal size of enclosure with wings 70 mm Enclosure Z size 66 mm SeaSoft Ltd 2017 SeaSoft kft www seasoft hu www mobil control eu T 62 406 405 M 36 30 255 7688 F 62 405 969 ...

Reviews: