background image

1.1.   ELECTRICAL SAFETY

 

 

  

WARNING!

 It is the responsibility of the owner and the  

 

   

operator to read, understand and comply with the following: You  

   

must check all electrical products, before use, to ensure that    

   

they are safe. You must inspect power cables, plugs, sockets    

   

and any other connectors for wear or damage. You must ensure  

   

that the risk of electric shock is minimised by the installation of   

   

appropriate safety devices. A Residual Current Circuit Breaker   

   

(RCCB) should be incorporated in the main distribution board.   

   

We also recommend that a Residual Current Device (RCD) is    

   

used. It is particularly important to use an RCD with portable    

   

products that are plugged into a supply which is not protected by  

   

an RCCB. If in any doubt consult a qualified electrician. You may  

   

obtain a Residual Current Device by contacting your Sealey    

   

dealer. You must also read and understand the following  

 

   

instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989

 requires that all portable  

 

   

electrical appliances, if used on business premises, are tested   

   

by a qualified electrician, using a Portable Appliance Tester  

 

   

(PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of  

 

   

electrical appliances responsible for the safe condition of those  

   

appliances and the safety of the appliance operators. 

If in any   

   doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is   

   

safe before connecting it to the power supply. See 1.1.1. and    

   

1.1.2. and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit    

   

and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or    

   damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance    

   

matches the power supply to be used and that the plug is fitted  

   

with the correct fuse (see 1.1.10. below).

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors.    

   

Immediately have any faulty item repaired or replaced by a  

 

   

qualified electrician.    

 

 WARNING! 

ELECTRICAL INSTALLATION TO  A 3 PHASE    

 

415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A  

 

 

QUALIFIED ELECTRICIAN.

  

1.1.10  This product must be fitted with a 3 phase plug wired as  

 

 

illustration in (fig.1), wired to an appropriately fused supply.

 

Connect GREEN/YELLOW wire to Earth ‘E’

 

Connect BROWN wire to L1 Terminal.*

 

Connect  BLACK wire to L2 Terminal.*

 

Connect the GREY wire to L3 Terminal.*

*NOTE:

 The cable core colours found in the mains cable on this  

 

compressor are consistent with 

Amendment 2 to 7671:2001.  When 

completed, check there are no bare 

wires, that all wires have been 

connected correctly and the cable 

restraint is tight

 

WARNING!

 

IT IS ESSENTIAL TO 

OBSERVE PULLEY DIRECTION ON 

INITIAL START UP, SEE PULLEY 

GUARD. IF INCORRECT, STOP 

IMMEDIATELY AND CONSULT A 

QUALIFIED ELECTRICIAN TO 

INVERT 2 PHASES*. 

 

1.1.11 

DO NOT

 use this product with 

an extension cable.

 

  

IMPORTANT USER 

INFORMATION!

  

 

Over-current protection of the power circuit is required in  

 

 

accordance with 7.2 of EN 60204-1:2006. The supply  

 

 

disconnecting device to be in accordance with 5.3 

 

of EN 60204-1:2006.

 

Ask a qualified electrician about compliance.

1.2.   GENERAL SAFETY 

3   

Familiarise yourself with the application and limitations of the    

   

compressor.   

 

3   

Ensure the compressor is in good order and condition before    

   

use. If in any doubt do not use the unit and contact an  

 

   

electrician/service agent.

   

WARNING! 

Compressor must only be serviced by an  

 

   

authorised agent. DO NOT tamper with, or attempt to adjust,  

   

pressure switch or safety valve.

3   

Before moving, or maintaining the compressor ensure it is  

 

   

unplugged from the mains supply and that the air tank pressure  

   

has been vented. 

3   

Maintain the compressor in good condition and replace any    

   

damaged or worn parts. Use genuine parts only. 

Unauthorised   

   

parts may be dangerous and will invalidate your warranty.

INSTRUCTIONS FOR:

 

COMPRESSOR - 500LTR BELT DRIVE 10hp 2-STAGE

WITH CAST CYLINDERS

MODEL No:

 

SAC65010B

 

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE 

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL 

INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

 1.  SAFETY

Original Language Version

 © Jack Sealey Limited

 SAC65010B     Issue: 1 - 24/12/14

fig.1

Guide to symbols

 

  

Warning: 

Electricity

 

  

Warning: 

Hot Surface

 

  

Warning: 

Automatic  

 

   

start up

 

 

   Wear ear protection

 

  

Read the instruction  

 

  manual before use

 

DO NOT

 open the air    

 

cock before an air hose  

 

is attached

 

  

 

DO NOT

 operate the    

 

compressor with 

 

enclosure displaced  

 

Ensure oil level is 

 

correct before first use 

  

 

Summary of Contents for SAC65010B

Page 1: ... an appropriately fused supply Connect GREEN YELLOW wire to Earth E Connect BROWN wire to L1 Terminal Connect BLACK wire to L2 Terminal Connect the GREY wire to L3 Terminal NOTE The cable core colours found in the mains cable on this compressor are consistent with Amendment 2 to 7671 2001 When completed check there are no bare wires that all wires have been connected correctly and the cable restra...

Page 2: ... 3 When not in use for a prolonged period and if possible store the compressor carefully in a safe dry childproof location Heavy duty three phase compressors suitable for the professional workshop Two stage pump system coupled with a 10hp motor maximises performance to keep running costs low compared to single stage single phase models A 500ltr tank allows for longer continuous air tool operation ...

Page 3: ...rol unit to the I position power On signified by the white indicator light E coming on 4 2 3 Turn switch B to start the compressor position 1 is compressor unit 1 operating only position 2 is compressor unit 2 operating only position 3 is both compressor units operating at the same time at staggered starting times timer in fig 6 4 2 4 When starting the compressor for the first time leave it runnin...

Page 4: ...ir leaks at connections Run compressor to max pressure switch off Brush soap solution over connections and look for bubbles Tighten connections showing leaks If problem persists contact Authorised Service Agent Pressure switch valve leaks when compressor is idle Non return valve seal defective Discharge all tank pressure Referring to fig 10 unscrew valve cap A Clean rubber disc B and its seat Refi...

Page 5: ...t WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Original Language Version Jack Sealey Limited SAC65010B Issue 1 24 12 14 01284 757500 01284 703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk We b Parts support is available for this product To obtain a parts...

Page 6: ...Original Language Version Jack Sealey Limited SAC65010B Issue 1 24 12 14 ...