background image

INSTRUCTIONS FOR:

DIRECT DRIVE COMPRESSOR

MODEL

:

SA2225/1.5.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2. GENERAL SAFETY INSTRUCTIONS

Familiarise yourself with the application and limitations of the compressor.  

Ensure that the compressor is in good order and condition before use. If in any doubt do not use. Contact an electrician/service agent.

p

p

WARNING! 

the compressor must be serviced by an authorised agent only. DO NOT tamper with, or attempt to adjust, the pressure

switch or the safety valve.

Before moving, or maintaining the compressor ensure that it is unplugged from the mains supply and that the air tank pressure has been vented. 
Only use recommended parts and accessories. To use unauthorised items may be dangerous and will invalidate your warranty.
Read the instructions regarding any accessory used with the compressor. Ensure that the safe working pressure of any air appliance used

exceeds the output pressure of the compressor.
Ensure that the air supply valve is turned off before disconnecting the air supply hose.
To move the compressor, use the handle only.  Lift the compressor so that the front legs give enough clearance for manoeuvring but maintain

unit’s centre of gravity in front of the wheels. 

DO NOT

attempt to lift or move the compressor by any means other than by the handle. 

Use the compressor in a well ventilated area and ensure that it is placed on a firm, level surface.
Keep tools and other items away from the compressor when it is in use and keep the area clean and free of unrelated items.
Ensure that the air hose is not tangled, twisted or pinched.
Keep children and unauthorised persons away from the work area.

DO NOT

dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

DO NOT

use the compressor outdoors, or in damp, or wet, locations and 

DO NOT

operate it within the vicinity of flammable liquids, gases or solids.

DO NOT

touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after shutdown.

DO NOT

attempt to move the compressor by pulling the air supply hose. Only move the compressor by the handle.

1.1. ELECTRICAL SAFETY

p  

WARNING! 

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.

A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected

by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.

and use a Portable Appliance Tester.

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6.

Important:

Ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7.

DO NOT

pull or carry the appliance by the power cable.

1.1.8.

DO NOT 

pull the plug from the socket by the cable.

1.1.9.

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely.

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only.

To rewire, connect the wires as indicated above - 

DO NOT

connect either wire to the earth terminal.

1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure

that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.

1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance

plugged into it will be protected. The section of the cores in the cable is important and should be at least 1.5mm

2

, but to be absolutely

sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend

the use of 2.5mm

2

section cable. 

1. SAFETY INSTRUCTIONS

FUSE RATING 13 AMP

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

SA2225/1.5.V2  - 1 - 010205

Summary of Contents for SA2225/1.5.V2

Page 1: ...ard We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical...

Page 2: ...raying 6 0 bar is recommended pressure setting for air tools 2 2 Weight Dimensions Model Weight kg Dimensions Length x Width x Height mm SA2225 1 5 V2 28 645 x 350 x 590 Free Air Delivery cfm Model Motor Output hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level Pressure Power dB A SA2225 1 5 V2 1 5 ...

Page 3: ...mpressor air in Air out is always less than air in due to losses within the compressor and so it is important that before choosing equipment you study the Free Air Delivery figures shown in the Specification Chart Section 2 p p WARNING Ensure that you have read understand and apply Section 1 Safety Instructions 4 1 Make sure that the main switch fig 4 1 is Off down 4 2 Plug the mains cable into ma...

Page 4: ...g from 5O C to 25O C SEALEY CPO or equivalent SAE 40 compressor oil Room temperature below 5O C SAE 20 compressor oil Approximate oil capacity 0 25 litres fig 5 6 TROUBLESHOOTING 7 DECLARATION OF CONFORMITY Internal external inspection of tank General cleaning of compressor Check tube fittings and electrical connections Check for oil leaks Replace air filter Clean intake filter Check oil level Dra...