background image

LIBRA

INSTALLATION MANUALS

AND SAFETY INFORMATION

SEA USA Inc.

10850 N.W. 21st unit 160 DORAL MIAMI 

Florida (FL) 33172 USA

Phone:++1-305.594.1151 Fax: ++1-305.594.7325

Toll Free: 800.689.4716

web site: www.sea-usa.com

e-mail: [email protected]

REV 11 - 09/2018

NEW MINI TANK

HALF TANK

FULL TANK

International registered trademark n. 2.777.971

67410246

Summary of Contents for Libra Full Tank

Page 1: ...N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com REV 11 09 2018 NEW MINI TANK HALF TA...

Page 2: ...danger 8 Do not allow children to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary...

Page 3: ...ng intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where...

Page 4: ...es on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past...

Page 5: ...to move toward a rigid objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL S...

Page 6: ...the whole movement of the leaf PRECAUTIONS SEA motors have been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous f...

Page 7: ...FULLTANK high quality hydraulic operator condominium industrial use max leaf length of 23 feet Ideal for CONTINUOUS use Available in 4 models AC up to 5 9 feet with lock in opening and closing for le...

Page 8: ...E TECHNICAL FEATURES 7 22 feet 23 feet 100 55 Use rate Max leaf length HALF TANK 19 68 feet 5 9 feet HALF TANK HALF TANK LARGE HT LARGE FULL TANK FULL TANK FULL TANK LARGE FULL TANK LARGE MINI TANK 9...

Page 9: ...ig 11 Release By pass valves Rear attachment Breather screw Front bracket Shaft Cover End cover Shaft FULL TANK Oscillating fork Brass pin short Long front fixation hinge Electric Motor Pump Distribut...

Page 10: ...tic frame Adjustm ent key By pass valves only for the installe r Aluminium release with key Optional Oil fill in cover Long front fixation hinge Brass pin short Breather screw R o d e n d m o u n t i...

Page 11: ...Adjustm ent key By pass valves only for the installe r Aluminium release with key Optional Small antivibration plastic frame Brass pin short Long front fixation hinge Breather screw Shaft NEW MINI TAN...

Page 12: ...ST have separate entrance TYPICAL INSTALLATION Fig 15 Fig 16 inside inside Outside Outside Inward installation Outward installation 1 Operator 2 Mechanical stop 3 Electronic control unit 4 Flashing la...

Page 13: ...13 inside outside a d b INWARD INSTALLATION c Fig 17...

Page 14: ...4 9 84 9 84 9 84 9 84 9 84 9 84 9 84 9 96 a inches b inches d max inches Max opening Angle Max stroke inches Stroke for 90 inches 4 92 6 69 2 95 125 14 48 11 61 5 11 6 69 3 14 125 14 64 11 81 5 51 9 2...

Page 15: ...15 inside outside OUTWARD INSTALLATION a d b c Fig 18...

Page 16: ...ches Max opening Angle Max stroke inches Stroke for 90 inches 9 84 3 93 100 14 01 13 46 10 03 3 75 95 13 58 13 22 10 43 3 75 95 10 62 3 54 90 12 99 10 82 90 12 79 10 82 90 12 55 9 84 9 84 3 54 3 54 13...

Page 17: ...the rear oscillating bracket as shown in Fig 19 Attach the spheric joint as shown in Fig 20 and 21 Start positioning the rear bracket as specified on following pages Rear oscillating bracket installa...

Page 18: ...he back fixation close the leaf and do as follows 1 Release the operator as in Fig 56 to 61 2 Pull out completely the chromium plated rod afterwards bring it back about 0 40 inches 3 Fix the rod on th...

Page 19: ...perfectly leveled NOTE If the brackets are installed before the operator place the front bracket inch lower than the rear bracket Fig 26 HT LARGE FT LARGE MINI TANK HT FT Fig 27 Fig 28 2 75 4 in Fig...

Page 20: ...parallel to the gate Fig 29 Fix the stop with the two included screws Put the provided bush A into the rod At this point hook the rod on the front fixation To adjust the stop in opening act on disc an...

Page 21: ...mechanical positive stops does not cause the reduction of the shaft stroke 1 Release the unit as in Fig 56 to 61 2 Let the rod come out about 3 4 of its run 3 Put the limit switch stops on the front...

Page 22: ...e sure that the two discs A and B perfeclty fit in opening phase Up Down BREATHER SCREW Fig 36 Fig 37 Unscrew and take off at the end of the installation IMPORTANT Take off the breather screw lower pa...

Page 23: ...pressure are similar with the opening pressure set slightly higher than the closing one By pass valves are placed under the key release system By pass valve 1 1 2 2 3 3 4 4 Grey Movement in opening Ye...

Page 24: ...external release mounting Kit for Half Tank Fig 43 Fig 44 Fig 45 Fig 46 by pass cover ALUMINIUM RELEASE WITH KEYMOUNTING HALF TANK MINI TANK Accessory on request EXTERNALRELEASE MOUNTING HALF TANK MI...

Page 25: ...ig 47 Fig 48 INSTALLATION ON MASONRY PILLARS MAKING A NICHE FullTank Version FullTank Large Version HalfTank MiniTank Version HalfTank Large Version Fig 49 If you have to make a niche observe the dime...

Page 26: ...n is adjustable by rotating the screw for the brake regulation Rotating clockwise Increase the effect of the slow down Rotating Anti clockwise Decrease the the effect of the slow down NOTE REMEMBER to...

Page 27: ...27 OIL LEVEL MEASUREMENT HALF TANK NEW MINI TANK Insertion into the motor in 3 34 2 16 3 34 Fig 53 OIL LEVEL MEASUREMENT FULL TANK Oil level Fig 54...

Page 28: ...examination to prevent in Fig 55 crushing conveying cutting grappling trapping so as to guarantee a safe installation for people things and animals Re Laws in force in the country where installation h...

Page 29: ...l it stops see Fig 59 remove it put it under the lid and close the lid again Attention Turning the key over 1 turn 360 could damage the release Turn the key anti clockwise to tighten the lid remove th...

Page 30: ...nti clockwise Fig 60 61 To relock the operator do as follows Insert the key and turn it clockwise until it stops Fig 60 61 Attention To release cut current supply PLASTIC RELEASE SYSTEM HALF TANK NEW...

Page 31: ...must contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Ele...

Page 32: ...0850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com International registered tradem...

Reviews: