SC 208

© by scala electronic gmbh, Germany

GEBRAUCHSANWEISUNG

BEAUTY TENS SYSTEM

INSTRUCTION MANUAL

BEAUTY TENS SYSTEM

MODE D`EMPLOI

BEAUTY TENS SYSTEM

Summary of Contents for SC 208

Page 1: ...SC 208 by scala electronic gmbh Germany GEBRAUCHSANWEISUNG BEAUTY TENS SYSTEM INSTRUCTION MANUAL BEAUTY TENS SYSTEM MODE D EMPLOI BEAUTY TENS SYSTEM ...

Page 2: ...batteries 7 HOW TO PREPARE THE SKIN How to prepare the skin 8 THE ELECTRODES How to apply the self adhesive electrodes 9 How to remove the self adhesive electrodes 9 Cleaning and storage of self adhesive electrodes 10 The electrodes do not stick 10 HOW TO USE YOUR BEAUTY TENS Functional description 11 Use 12 PLACING THE PADS Body tightening 13 Body styling 14 Body styling and shaping 15 GENERAL Tr...

Page 3: ...e the instrument successfully for body styling body slimming and body tightening We wish you much success and lots of fun with your new training partner Beauty Tens SC 208 Your s cala team Features of the Device The Beauty Tens SC 208 has a digital operation dis play system DODS The display shows the current treatment mode while your are using the device You have 7 different programs and 7 intensi...

Page 4: ...he muscles exercised by the electrical pulses The improved metabolism of the muscles burns extra calories and eliminates spent material The body styling improves because excess fat gradually disappears your body gets a healthier shape and the musculature is tightened Your whole body improves The Beauty Tens device has 7 programs and 7 intensity levels The different electrical pulses can cause diff...

Page 5: ...trodes are removed until the cause of the irritation is diagnosed Note The electrodes must always be completely clean and the skin must be thoroughly dry Avoid adjusting controls while operating machinery or a vehicle Always turn the device off before applying or removing electrodes The device does not have explosion protection Do not use it in the presence of explosive or flammable material Do no...

Page 6: ...el Higher out put intensity key Start key 3 batteries 1 5V Program mode switchDispla y Lower out put intensity key Battery compart ment cover Socket for electrodes channel 1 Socket for electrodes channel 2 On off button Beauty Tens SC 208 with connected electrodes Fig 2 Fig 1 ...

Page 7: ... new ones Note the correct polarity of the batteries see information inside the battery compartment Caution There is a risk of explosion if the batteries are fitted incorrectly Do not dispose of exhausted batteries in a fire and keep them out of reach of children Return the exhausted batteries to an official collection point If you use rechargeable batteries please be sure to follow these instruct...

Page 8: ... your physician for preparing the skin Many skin problems arise from the pulling stress of adhesive patches that are excessively stretched across the skin during application To prevent this apply the electrodes from the centres outward Avoid stretching over the skin To minimise pulling stress lay out the extra lengths of electrode lead wire in a loop to prevent tugging on the electrodes When remov...

Page 9: ...odes when you buy it How to apply the self adhesive electrodes Clean and dry the skin thoroughly in the area you want to treat with soap and water prior to application of the electrodes Insert the lead wires into the plug connectors on the pre wired electrodes and also into the electrode jack on the device Fig 6 Remove the protective liner from the electrode and apply the electrode firmly to the t...

Page 10: ...rded when they are no longer adhering The electrodes do not stick Oily skin Try thoroughly cleaning the skin with soap and water and dry the area well around the electrode sites Hairy skin Clip away the hairs around the location of the electrodes with scissors Do not shave the area Perspiration The adhesive used on the electrodes is water based If it becomes saturated it will lose its adhesive qua...

Page 11: ...program please read the chapter Technical specifications page 16 of this booklet You can chose from 7 programs Setting the time of treatment After confirming the program selection with the MODE key the timer symbol blinks You can set the required treatment time of 15 30 or 60 minutes and confirm the setting with the MODE key The timer will blink Now press the CH START key and set the required inte...

Page 12: ...fortably and select the required treatment time Start with maximum 30 40 minutes per day Observe at least 4 hours in between two treat ment sessions on any one day 7 Gradually increase the intensity of treatment Ob serve the maximum muscle contraction Because muscles react differently to the treatment you can vary the treatment intensity during a session 8 The device turns off at the end of the tr...

Page 13: ... to improve the shape of the arms and shoul ders Slack musculature is strengthened To improve the firmness of abdominal muscles apply the electrodes to the different muscle groups Tightening and strengthening the inner and outer thigh musculature ...

Page 14: ...Training to strengthen the shape the musculature of the abdomen The flabby skin becomes firmer Training to shape the back musculature The electro des are placed on the back muscles Training to shape the upper thigh and buttock muscles ...

Page 15: ...ing and shaping Training to shape the upper rear thigh and calves and make them firm Training to shape and waistline and the belly Effec tively supports slimming Upper thigh and buttock training also facilitates loss of body weight ...

Page 16: ...teries for proper no reaction after installation turning on the device Check batteries for reversed polarity Install new batteries if necessary Check plug connections and l ead wires correct if necessary Stimulation becomes Check electrodes for proper weak seating Clean electrodes if necessary Oily skin clean and dry skin if necessary Stimulation stops Check batteries during treatment after Remove...

Page 17: ...z 250 µs Burst output 60 Hz 250 µs Burst output 60 Hz 250 µs Dense and disperse 5 60 Hz 250 µs Modulated output 60 Hz 250 µs Dense and disperse 5 60 Hz 250 µs Auto recycle 5 60 Hz 250 µs Wave form 1 asymmetrical bi phase square pulse Timer 15 30 60 minutes Sets of memory Last memory display Power supply 3 x AAA 4 5 V Dimensions 148 mm L x 58 mm W x 25 mm H Weight approx 105 grams The device meets ...

Page 18: ...ly to damage resulting from failure to follow the operating instructions accidents abuse alteration by unauthorised individuals During the warranty period the defective device can be sent freight collect to the customer service address given below Please add the purchase voucher and a description of the problem encoun tered You will then receive a new or your repaired device free Repairs after the...