background image

Instruction Manual   

Vapor Pressure Type Remote Sensing Dial Thermometer   

Model VB-100P 

 
 

Thank you for purchasing the Remote Sensing Dial Thermometer model VB-100P. 

-

 

This product is designed to measure temperature. Do not use it for other purposes. 

-

 

Read this manual thoroughly before using the thermometer and keep this manual in a safe place 

for your future reference. 

 

Names of Sections 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

How to Install

 

  Unpack and remove all the packing materials.

 

 

  Check all the specifications of the unit accord to your requirements such as temperature range, 

length of lead wire, connection type and etc. 

  Check the temperature value in the normal temperature. 

 

 

Cautions     

For your safety and proper use of the thermometers, make sure to observe the followings: 

-

 

Always have the whole sensing stem touching the measuring object to avoid any measuring errors. 

-

 

The main unit is splash-proofed, not waterproof type.   

-

 

Do not install the main unit in a place exposed to high temperature (higher than 50

), high 

humidity (higher than 80% rh), vibrations or high corrosiveness. 

-

 

Do not alter the casing by forcibly reaming the holes for bigger screws or even opening new 

holes. 

-

 

For the all-time use, it is recommended to use the thermometer in an environment less than   

70 to 80 % of the maximum measuring range. Otherwise, it will be the cause of malfunction. 

-

 

Do not bend, pull or twist the lead wire. Doing so may cause wire breakage. 

-

 

Always have the packing ring between the fixing screw and the sensing stem to avoid leakages. 

 

Troubleshooting 

-

 

Immovability of the pointer

 can be caused by failure of the magnifying mechanism and/or gas 

leakage from the bourdon tube or the welded area. 

Lead wire 

Case 

Sensing stem 

3-Ø 5.5hole 
PCD.122 120

°

Pitch 

(38) 

3.3 

14.5 

100 

18 

Ø1

1

0

 

Ø9

2

 

Ø1

3

6

 

Ø8

 

Reviews: