background image

INSTALLATION INSTRUCTIONS

1 CHANNEL PROGRAMMER

Technical Data

Power Supply: 

 

 

230V AC, 50Hz

Operating Temperature:   

0°C to 35°C

Total Switch Rating: 

 

230V AC, 6(2)A

Contact Type:                           

1B , Micro-Disconnection (Voltage Free)

Battery Type: 

 

 

Lithium Cell CR2032 

 

 

 

Enclosure Protection                 

IP30 

Plastics                                   

Thermoplastic, flame retardant

Insulation Class                      

Double

Wiring:   

 

 

For fixed wiring only

Backplate                  

 

Industry standard

Dimensions: 

 

 

140mm x 87mm x 37mm

Clock                                       

12 hour am/pm, 1 minute resolution

BST/GMT time change             

Automatic

Clock Accuracy                         

+/- 1 sec per day

Program Cycle                            24hr, 5/2day or 7day selectable.

Program On/offs per day           

2on/off, 3on/off selectable

Program Resolution                   

10mins

Program Selection                     

Auto, On all day, On constant, Off

Program Override                     

+1,2 or 3Hr, Advance

Complies with                          

EN60730-1, EN60730-2.7,  EMC Directive 2004/108/EC, 

    LVD 

Directive 

2006/95/EC

              

Pre-Installation Product Set Up

:

Before installing, set the bank of 4 DIP Switches on the back to configure the unit according 

to the chart below:

 

DIP Switches: Shown in Factory Default Positions.
24 Hr – runs same programme every day.
5/2 Day – allows different on/off times at weekend.
7 day – allows different on/off times every day.

Electrical Connections

Internal Wiring Diagram

 

Note: The Switch is volts free. COM should be linked to L for mains switching.

Fitting the Programmer

Loosen the two ‘captive’ retaining screws on the bottom of the back 

plate. Now fit the programmer to the back plate, ensuring the lugs of 

the back plate engage with the slots on the programmer. Swing the 

bottom of the programmer into position ensuring the connection pins 

on the back of the unit locate into the terminal slots in the back plate.

Tighten the two ‘captive’ screws to fix the unit securely

Commisioning

Switch on mains supply.

Referring to the user guide 

1. Use the buttons to ensure correct product functionality. 

2. Set timing and programme details in accordance with customer requirements.

3. Normally unit will be left with channel in ‘Auto’ mode.

4. Leave these installation instructions with customer for reference.

In the interests of continuous product improvement we reserve the right to alter designs, 

specifications and materials without prior notice and cannot accept liability for errors.

143702_A

Sangamo Limited, Industrial Estate, Port Glasgow,  Renfrewshire   PA14 5XG

Tel: 01475 745131    Fax: 01475 744567 

Email: [email protected]    Web: www.sangamo.co.uk

CHOICE PR 1

SERVICE AND WARRANTY

Your product is not user serviceable.  PLEASE DO NOT TRY TO DISMANTLE THE UNIT.

This product is guaranteed by your supplier for 3 years from the Date of Manufacture.  If it should become 

defective, please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns.   

An extended warranty may be purchased online (www.sangamo.co.uk/warranty)

CUSTOMER CARE POLICY

As part of Sangamo’s continuous improvement program, the Company operates a Customer Care Policy.  

This means that we welcome your comments and complaints, as it can help us to improve our services to you, 

our customer.

Due to our policy of continuous product improvement and development, the specifications in this guide may be subject to 

change without prior notice.

Technical Helpline: 01475 745131

Summary of Contents for choice pr 1

Page 1: ...the bottom of the programmer into position ensuring the connection pins on the back of the unit locate into the terminal slots in the back plate Tighten the two captive screws to fix the unit securely Commisioning Switch on mains supply Referring to the user guide 1 Use the buttons to ensure correct product functionality 2 Set timing and programme details in accordance with customer requirements 3...

Page 2: ...e IT IS ESSENTIAL that the metal be earthed DO NOT use a surface mounting box No earth connection is required as the product is double insulated but ensure continuity of earth throughout the system NEVER fit or remove the unit to a live wall plate Fitting Back Plate Direct Wall Mounting 1 Position the wall plate terminals along top edge with 60mm min clearance to its right 25mm min above 90mm min ...

Page 3: ...ilure the screen will go blank but the back up battery ensures that the programmer continues to keep the time and retain your stored programme When power is restored if there has been no change to the rear DIP switch the programmer then goes to RUN mode If the configuration setting on the rear DIP switch has been altered during the power interruption the screen will initially show the new configur...

Page 4: ... Configuration Display 2 ON OFF Pumped System 2PU 3 ON OFF Pumped System 3PU The 24 hour or 5 day 2day or 7 day programming option as set up by the installer can also be verified at this stage by how the Monday to Sunday indicators are displayed Programming option Monday to Sunday Indicators flash 7 DAY Mon to Sun individually shown 5 2 DAY Mon to Fri together then Sat Sun together shown 24 HOUR M...

Page 5: ...rammer the initial programme displayed will be for Monday to Friday Pressing the DAY button will take you to the programme for Saturday and Sunday The ON OFF times can be changed for each day group as described above in the section CHANGING PROGRAMME TIMES If you press COPY button the current programme will be copied onto the next day group 24 hour programmer option If the unit is installed as a 2...

Page 6: ...utton 3 to set month Press NEXT button 5 D XX appears Day Press button 3 to set day You can review or edit the date you have set just by pressing NEXT button 5 again and repeating the sequence above To confirm the date and move on to PROGRAM mode press SET button 1 once or press SET button 1 multiple times to return to RUN mode CHANGING PROGRAMME TIMES The built in programmes can easily be changed...

Reviews: