background image

 

 
 

 

Mini Pulse Electronic Stimulator 

Model: PM-180 

 

 

 

 

Operating Manual 

IMPORTANT: 

Please read all instructions before using this product. 

Retain this manual for future reference. 

 
 
 
 
 

www.santamedical.com 

Summary of Contents for PM-180

Page 1: ...Mini Pulse Electronic Stimulator Model PM 180 Operating Manual IMPORTANT Please read all instructions before using this product Retain this manual for future reference www santamedical com ...

Page 2: ...s thrombophlebitis varicose veins Apply stimulation only to normal intact clean healthy skin 4 In the presence of electronic monitoring equipment e g cardiac monitors ECG alarms The electronic Stimulator may not operate properly when the electrical stimulation device is in use 5 While operating machinery or during any activity in which electrical stimulation can put you at risk of injury 6 On chil...

Page 3: ...s are generated by the device and delivered through the connecting wires and electrodes to the target body areas PM 180 helps relieve pain in various parts of the body such as the lower back shoulders hands and feet Santamedical PM 180 has 8 operation modes Its screen can show the battery power selected mode current intensity and remaining time The device is equipped with accessories of four elect...

Page 4: ...Channels Outlets 8 Mode Selector 2 On Off Switch 9 Pads and Wires Collector 3 LCD Screen 10 Electrode Pads 4 USB Port 11 Lead Wires 5 Intensity Increase Decrease 12 USB Cable 6 Timer 13 USB charger 7 Play Pause Button 14 Battery Indicator ...

Page 5: ...ould pause the device press again to resume 8 Pressing the T button could select different countdown periods of time from 10 to 60 min 9 When done turn off the device and put away the connecting wires and electrode pads Note Start from the lowest intensity and then gradually adjust to a comfortable level on a scale level from 1 to 10 Recommended practices 1 Duration of 20 minute for each body area...

Page 6: ...he unit was previously used switch the power to OFF first then back to ON Stimulation is weak or not existent Be sure pads are firmly attached to skin Be sure the pads are not touching each other Check the wire connection and make sure the lead wires are securely plugged into the device Check if the battery is low and needs to be recharged Both pads from the same wire must be attached to one perso...

Page 7: ...re available at www santamedical net under Electrotherapy category Contact Us For any inquiries of comments concerning our products please send email to support gurinproducts com and we will contact you as soon as possible If there is any quality related issue with the product you may request a replacement or refund by submitting a request at http support gurinproducts com Statement We are only ab...

Reviews: