background image

 

 

 

Summary of Contents for Ubigate iBG1003

Page 1: ......

Page 2: ...any and product names may be trademarks of the respective companies with which they are associated This manual should be read before the installation and operation and the operator should correctly install and operate the product by using this manual This manual may be changed for the system improvement standardization and other technical reasons without prior notice If you have a question for the...

Page 3: ...rovide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferen...

Page 4: ...d on the bottom of the chassis The label contains Product Identifier Number FCC Registration Number Ringer Equivalence Number REN If requested this information must be provided to your telephone company Unauthorized Modifications Any change or modifications performed on this equipment that are not expressly approved in writing by SAMSUNG ELECTRONICS CO LTD could cause non compliance with the FCC r...

Page 5: ...r plug is provided with this product which is designed to connect to a compatible Standard Modular jack Connection to the telephone network should be made by using standard modular telephone jacks type RJ 11C The RJ 11C plug and or jacks used must comply with the FCC Part 68 rules CIRCUIT TYPE PORT TYPE FACILITY INTERFACE CODE NETWORK JACK LOOP START LINE FXO T1E1 02LS2 04DU9 DN 04DU9 1KN 04DU9 1S...

Page 6: ... Harm The telephone company will notify you in advance about the temporary discontinuation of service if the Ubigate iBG1003 equipment is causing harm to the telephone network In case advance notification is not feasible the telephone company will notify the customer as soon as possible and you will also be advised about your right to file a complaint with the FCC if it is necessary Changes to Tel...

Page 7: ...t from the network until the problem is resolved Field Repairs Only technicians certified on the Ubigate iBG1003 are authorized by SAMSUNG ELECTRONICS CO LTD to perform system repairs Certified technicians may replace modular parts of a system to repair or diagnose trouble Defective modular parts can be returned to SAMSUNG ELECTRONICS CO LTD for repair General Connection to party line service is s...

Page 8: ...ant Routed to a recorded announcement that can be administered by the Customer Premises Equipment CPE user Routed to a dial prompt 2 This equipment returns answer supervision on all DID calls forwarded to the PSTN Permissible exceptions are A call is unanswered A busy tone is received A reorder tone is received Equal Access Requirements Through the use of access codes this equipment is capable of ...

Page 9: ...icense may be required from the American Society of Composers Authors and Publishers ASCAP or other similar organizations if copyright music is transmitted through the Music on Hold feature SAMSUNG ELECTRONICS CO LTD hereby disclaims any liability arising out of failure to obtain such a license Direct Inward System Access DISA Warning The lines used for the DISA feature must have the disconnected ...

Page 10: ...nection Energy Hazard careful treatment is needed Every wire for communication should be larger than 26 AWG Double pole neutral fusing Underwriters Laboratories The Ubigate iBG1003 system has been tested to comply with Safety Standards in the United States and Canada This system is listed with Underwriters Laboratories The cUL Mark is separately shown on the label ...

Page 11: ...ot work on energized equipment Working on energized equipment can result in serious electrical shock To avoid electric shock do not connect Safety Extra Low Voltage SELV circuits found in LAN ports to Telephone Network Voltage TNV circuits found in WAN ports This equipment must be installed and maintained by properly trained service personnel Make sure the proper electrical service is available be...

Page 12: ...e the following guidelines to minimize the potential for Electrostatic Discharge ESD damage which can cause intermittent or complete component failures When handling Ubigate iBG1003 or its components wear grounding wrist straps to avoid ESD damage to the equipment Do not directly touch the backplane with your hand or any metal tool or you could shock yourself 1 Always use an ESD wrist strap or ank...

Page 13: ...cards Tighten the captive installation screws to ensure a proper connection when inserting modules or interface cards 4 When removing or installing a component always place it component side up on an antistatic surface in an antistatic card rack If you are returning a component place it in an electrostatic bag before packing it ...

Page 14: ...GENERAL USER INFORMATION XII SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Page 15: ...IV Changes to Telephone Company Equipment or Facilities IV Service Center V Field Repairs V General V Direct Inward Dialing DID VI Equal Access Requirements VI Electrical Safety Advisory VII Music on Hold Warning VII Direct Inward System Access DISA Warning VII Safety Warnings VIII Underwriters Laboratories VIII Installation Safety Guidelines and Warnings IX CHAPTER 1 Verifying the Ubigate iBG1003...

Page 16: ...cting the Ubigate iBG1003 3 1 Console Port 3 1 Ethernet Port 3 3 Powering Up the Ubigate iBG1003 3 4 Connecting AC Power 3 4 Applying Power 3 5 CHAPTER 4 Getting Started 4 1 Initial Administrator Login 4 1 Changing the Administrator Login ID 4 3 Changing the Administrator Password 4 4 Changing the System Host Name 4 5 Date and Time 4 6 Setting the time using UTC command 4 6 Setting the date using ...

Page 17: ...Ubigate iBG1003 Quick Start Guide SAMSUNG Electronics Co Ltd XV Verifying the Hardware Configuration 4 10 Initializing Configuration 4 11 ...

Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Page 19: ...ping crate Do not unpack it until you are ready to begin installation A packing list is included in each shipment The packing list specifies the part numbers and descriptions of each part in the shipment Verify the parts received against the list Your package contains the following items Ubigate iBG1003 Router Console cable DB 9 to RJ 45 cable adapter One UTP Ethernet cable Rack mount package opti...

Page 20: ...e iBG1003 Quick Start Guide Ubigate iBG1003 Manual CD If any part is missing or damaged contact Samsung Technical Support http www samsung com global business telecomm footer Footer_Cont actUs html Save the shipping crate cover pallet and packing materials in case you need to move or ship the router at a later time ...

Page 21: ...iBG1003 has LEDs to indicate the iBG1003 routers performance and operation status as shown in figure below Proper LED status is shown in the following table LED Indication Color Description Power Solid blue Power supply installed and operating normally Amber Power supply installed but power fault condition detected Off Power supply not present or Power supply malfunctioning SYS Solid green System ...

Page 22: ...ent but malfunctioning Off Fan has been stopped by user configuration P0 P3 T1 E1 Solid green T1 E1 port is operating normally Solid red T1 E1 port cable is not connected properly or a critical alarm has been detected Amber User alarm detected Off System is not operating normally or port is disabled Link0 1 Ethernet Solid green Ethernet port link is detected Off Ethernet port link is not detected ...

Page 23: ...dule or 4 port Fast Ethernet switch module can be plugged into this slot Voice option module slot A voice option module can be plugged into this slot One is pre assembled in the factory in order to meet different deployment needs The following voice option modules are available 2 FXO 4 FXS 2 FXO 8 FXS 2 FXO 16 FXS 2 FXO 2 T1 E1 2 T1 E1 4 FXS T1 E1 ports T1 E1 WAN connection Ethernet ports Fast Eth...

Page 24: ...CHAPTER 1 Verifying the Ubigate iBG1003 1 6 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Page 25: ...delines and Warnings before you start installing the router Desktop Installation For installing chassis you must secure unrestricted airflow for chassis cooling Place the Ubigate iBG1003 router on a clean flat stable surface with at least 18 by 19 inch of clear space to allow sufficient room for interface cabling power cord clearance and adequate ventilation Do not place anything on top of the rou...

Page 26: ...ing the router on a rack you need to attach brackets to the router The brackets can be ordered separately 1 Attach the mounting brackets to the router as shown in figure below using the 4 of M4xL8 screws included 2 Attach the second bracket to the opposite side of the router Use a number 2 Phillip screwdriver to install the bracket screws ...

Page 27: ...u have attached the brackets to the router use the screws provided with the rack to install the chassis in the rack 1 Align the bracket holes of the router with the desired holes of the rack 2 Attach the Ubigate iBG1003 to the rack according to the instructions provided by the rack manufacturer ...

Page 28: ...ing the Ubigate iBG1003 You must connect the chassis to a reliable earth ground as shown in below figure Verify the following The grounding cable is correctly installed It does not touch or block access to router components It does not drape when people accidentally trip on it ...

Page 29: ...necting the Ubigate iBG1003 This section describes procedures to connect various interfaces and console port of the Ubigate iBG1003 Follow the procedures for interfaces appropriate for your network facility environment Console Port A terminal VT 100 or equivalent or workstation with terminal emulation software can be used for the operator console To use a system console to configure and manage the...

Page 30: ...cable into the console port on the Ubigate iBG1003 as shown in below figure 2 Plug the other end of the cable which has the adapter with the female DB 9 connector to the communication port on the workstation or terminal 3 Configure the workstation or the terminal for 9 600 bps 8 data bits 1 stop bit no parity and no flow control ...

Page 31: ...ts Use a Category 5 minimum Ethernet cable with RJ 45 connectors to connect to the network via an Ethernet port 1 Plug one end of the Ethernet cable into the appropriate Ethernet port on the target router 2 Plug the other end of the cable into the network device Make sure that the cable connectors are locked and secure in the ports ...

Page 32: ... Up the Ubigate iBG1003 The Ubigate iBG1003 has a 72 Watts AC power supply module Connecting AC Power To connect the AC power cord to the router 1 Connect the AC power connector to the power supply 2 Connect the other end to a grounded power receptacle rated for the Ubigate iBG1003 ...

Page 33: ... Ubigate iBG1003 is connected to a power source 2 Switch the rocker switch on the Ubigate iBG1003 rear side to the on position Then the fan starts the LEDs start to blink in different colors and the Ubigate iBG1003 performs a self test On successful completion of the self test the system SYS LED will indicate Green and the other LEDs will be in various states This is a normal condition when the ro...

Page 34: ...CHAPTER 3 Connecting the Ubigate iBG1003 3 6 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Page 35: ...mpt is displayed on the console screen 2 To login enter default login ID and password for the administrator The default login ID for the administrator is samsung The user can change the login ID to suit his her needs after the initial login The default password for the administrator is samsung The password has to be changed as soon as possible to ensure that only authorized access to the system is...

Page 36: ... Started 4 2 SAMSUNG Electronics Co Ltd The login sequence and related prompts are shown below login samsung password samsung Router For more information about command usage see the Ubigate iBG series Command Reference ...

Page 37: ...rity reasons it is strongly recommended to change the login ID as soon as possible To change the login ID follow the steps below 1 Enter the configuration mode by executing the following command Router configure term 2 Change the administrator login name as shown below Router configure admin_name SAbob This example changes the login ID to SAbob 3 A confirmation message Administrator account name c...

Page 38: ...possible To change the password follow the steps below 1 Execute the password command Router password The system prompts for the current user name 2 Type samsung and press Enter The system prompts to enter the old password 3 Type samsung and press Enter The system prompts to enter a new password 4 Type a new password and press Enter The system prompts you to verify the new password 5 Type the new ...

Page 39: ...nterface CLI prompt name To configure the host name follow the steps below 1 Enter the configuration mode by executing the following command Router configure term 2 Type hostname followed by the new host name as shown below and press Enter Router configure hostname Samsung In the above example the new host name is Samsung 3 The CLI prompt changes to Samsung accordingly Samsung configure ...

Page 40: ... Specify the time zone offset ahead or behind the time in GMT Greenwich Mean Time Enter the number of hours and minutes ahead or behind the GMT For example to set the local Pacific Standard Time to UTC time type as shown below and press Enter Router configure utc 08 00 Setting the date using Date command To set the date enter in the format of MM DD YYYY Month Day Year For example to set the date t...

Page 41: ...Setting the time using Time command To set the time enter in the format of HH MM SS Hour Minute Second For example to set the time to 18 14 30 enter time 18 14 30 as shown below and press ENTER Router configure time 18 14 30 MON OCT 24 18 14 30 2005 Router configure ...

Page 42: ...r remove this information To add a new user follow the steps below 1 Enter the configuration mode by executing the following command Router configure term 2 Type user followed by the user name and access level optional as shown below Router configure user John level 2 In this example the user name is John and access level is 2 Then the system prompts you to enter a new password 3 Enter a new passw...

Page 43: ...the system To remove a user follow the steps below 1 Enter the configuration mode by executing the following command Router configure term 2 Type no user followed by the user name and press Enter Router configure no user John 3 The specified user is removed from the system You can use the show user_accounts command to view user information ...

Page 44: ...ctronics Co Ltd Verifying the Hardware Configuration To view the current hardware configuration 1 Execute the show chassis command Router show chassis 2 Execute the following command as shown below Router show version Router show running config ...

Page 45: ...stem by executing the reboot command After following the steps described above the system cfg file no longer exists Subsequently an error message file not found is displayed upon rebooting the system This message will not impact operation and it should be ignored You can generate the system cfg file by executing the save local command The clear cfg file command does not remove user account informa...

Page 46: ...CHAPTER 4 Getting Started 4 12 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Page 47: ...ld not be mixed with other commercial wastes for disposal BATTERY SYMBOL INFORMATION Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their work...

Page 48: ......