background image

Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.  

SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner.

\\USER MANUAL

SALTO WRLUD24Bxx 

|  Long Distance Reader  

The SALTO Long Distance Reader is a complementary 
unit that connects to the XS4 2.0 online Controller to 
automatically identify users flows at long range.

Long Distance Reader 

WRLUD24Bxx

Summary of Contents for WRLUD24B series

Page 1: ...reproduced in any form or by any means without written permission from the copyright owner USER MANUAL SALTO WRLUD24Bxx Long Distance Reader The SALTO Long Distance Reader is a complementary unit that...

Page 2: ...TO Systems WRLUD24Bxx Long Distance Reader manual 2 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited with...

Page 3: ...contains confidential and privileged information The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S L Index 1 TECHNICAL DATA 5 2...

Page 4: ...ing interference that may cause undesired operation In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or un sh...

Page 5: ...IP65 Operating Temperature C F 20 50 4 122 Relative Humidity 5 95 non condensing Power Requierement 12 28 20 VDC max 1 A Frequencies MHz 865 868 EU MHz 902 928 US MHz 916 921 JP 4W E I R P MHz 916 92...

Page 6: ...6 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S...

Page 7: ...LTO Systems S L 3 WIRING 3 1 Installation notes 3 1 1 Installing the earth terminal The earth terminal is supplied with the unit and can be installed at the prepared location when needed for example w...

Page 8: ...control unit The WRLUD24Bxx uses the WRLUD SIC1 converter to connect to the CU42E0 fo llowing the above drawing The long distance reader must be power supplied externally The 4 wires cable connects t...

Page 9: ...confidential and privileged information The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S L Example The power supply is not deli...

Page 10: ...nting on poles and pipes For installation on a mast or tube the baseplate included in scope of supply see Sec tion 5 1 1 must be mounted on the rear of the WRLUD24Bxx so that it can be adjusted vertic...

Page 11: ...alls and ceilings For mounting on walls or ceilings the ball joint bracket WRLUD MB1 optional see chapter 5 2 1 can be mounted directly onto the back of the reader This mounting aid allows to adjust t...

Page 12: ...sorb the carrier signal Therefore the installer has to make sure that the front of the reader and the transponder is not covered with wa ter ice or snow 3 Reflections within the surroundings of the re...

Page 13: ...ce Given the condition that the transponder is aligned towards the reader a detection range as shown in the figure below is the result when the reader is operated detached The reading range varies due...

Page 14: ...ir cumstances of the application The test mode can be activated with the test transponder WRLUD 4TT08 kit within 30 seconds after the unit is switched on After activation the antenna is first automati...

Page 15: ...to a power supply unit itself To do so a special wall power supply is availa ble The drivers can be downloaded from www saltosystems com Connect as follows WRLU Description Description WRLUD24 Pin1 V...

Page 16: ...nfiguration Software WebConfig Reader WRLUD24Bxx 1 Connect the reader to the WRLUD SNG3 see table page 16 connect the WRLUD SNG3 to the PC via the USB cable connect wall power supply to WRLUD SNG3 2 S...

Page 17: ...SALTO Systems S L Device info Serial number Serial number of device Device Identification code of device Version Firmware version SW and hardware version HW of device Region Region the device is autho...

Page 18: ...a multi reader environment EU only use different channels for the readers Use the Preferred channel parameter to make this setting Select the greatest possible separation Channel mask This mask define...

Page 19: ...W Singapore Channel No Frequency E R P 1 920 25 MHz 2 00 W 2 920 75 MHz 2 00 W 3 921 25 MHz 2 00 W 4 921 75 MHz 2 00 W 5 922 25 MHz 2 00 W 6 922 75 MHz 2 00 W 7 923 25 MHz 2 00 W 8 923 75 MHz 2 00 W...

Page 20: ...00 W 23 920 4 MHz 4 00 W Korea Channel No Frequency E I R P 2 917 1 MHz 4 00 W 5 917 7 MHz 4 00 W 8 918 3 MHz 4 00 W 11 918 9 MHz 4 00 W 14 919 5 MHz 4 00 W 17 920 1 MHz 4 00 W Japan Low Power Channe...

Page 21: ...ohibited without the prior written consent of SALTO Systems S L China Channel No Frequency E R P 1 920 625 MHz 2 00 W 2 920 875 MHz 2 00 W 3 921 125 MHz 2 00 W 4 921 375 MHz 2 00 W 5 921 625 MHz 2 00...

Page 22: ...Systems WRLUD24Bxx Long Distance Reader manual 22 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited withou...

Page 23: ...Systems WRLUD24Bxx Long Distance Reader manual 23 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited withou...

Page 24: ...lity com SALTO Systems Netherlands Amsterdam The Netherlands Tel 31 206 353 100 email hospitality nl saltosystems com www saltohospitality com SALTO Systems Belgium Brussels Belgium Tel 31 206 353 100...

Reviews: