background image

1

Model CS Crane Scale
User Instructions

1.0

General Information

Thank you for purchasing the Model CS crane scale. Please read all operating 
instructions carefully before using and note the following safety items:

• Do not overload the scale. This will damage the loadcell and void the 

warranty.

• Do not leave weights hanging from the scale for long periods. This could 

decrease the accuracy of the scale and shorten the life of the loadcell.

• Inspect the shackle and hook regularly.

• Check the battery visually periodically and recharge as needed.

• To maximize battery life, charge it periodically, with the included charger, 

when not in use for long periods of time 

• Do not attempt to repair the scale if you have a problem. Contact your 

local Salter Brecknell representative.

2.0

Battery and Recharging

To save battery power, the unit will enter a low power mode after a few minutes 
of stable weight reading. During low power mode, the display will show a 
flashing segment in the right most part of the display.

If there is no scale activity within 60 minutes, the scale shuts off completely.

When you first receive your scale, plug the AC adapter into a properly 
grounded 120VAC outlet and plug the charging jack into the receptacle at the 
top of the scale on the back panel. The red light should come on next to the 
receptacle to show that charging is taking place. When the light turns green the 
battery is fully charged. 

Battery life should be at least eight hours after charging.

Summary of Contents for CS

Page 1: ...r long periods of time Do not attempt to repair the scale if you have a problem Contact your local Salter Brecknell representative 2 0 Battery and Recharging To save battery power the unit will enter...

Page 2: ...nual instructions that include key names will refer to front panel keys unless RC precedes the key name That will mean the key being referred to is the remote control key of that name Figure 1 1 shows...

Page 3: ...Clearing the Accumulator on page 7 RC M Press this remote control key to add the displayed weight to the memory accumulator See Performing Viewing and Clearing Weight Accumulation on page 6 RC F1 Pres...

Page 4: ...and 3 to weigh the next object Performing a Tare Weighment 1 With the scale on and showing 0 0 weight hang the load to be tared from the hook The gross weight is displayed 2 Press the TARE or RC TARE...

Page 5: ...o accept this value and return to net weighing mode The TARE annunciator lights and the value you entered is displayed as a negative number 5 Hang the container of the known tare weight you ve entered...

Page 6: ...layed briefly then LXXX X is displayed These displays repeat and then the scale returns to normal weighing mode with the current weight displayed no 001 is the number of accumulations done so far The...

Page 7: ...is in kg unit of measure the display will show un 1 briefly the lb annunciator lights and the scale returns to normal weighing mode with lb as the active unit of measure If the unit is in lb unit of m...

Page 8: ...ey until the unit beeps The scale will briefly show the battery voltage and then will turn off Adjusting the Display Brightness To set the brightness of the display follow these steps 1 Press the RC F...

Page 9: ...rce Displayed reading changes The load is unsteady The loadcell is damaged Humidity too high Stabilize the load Check and replace loadcell Place unit in dry envirornment Scale will not show 0 Scale ha...

Page 10: ...ight exceeds 99999 99999 is the upper accumulated weight limit CLr This is a prompt to see if you really want to clear the accumulated weight noCLr This means you aborted the clearing process 8 8 8 8...

Page 11: ...tery type Sealed lead acid 6V 5Ah Adapter DC9V 1500mA Operating Temp 10 F to 104 F 10 C to 40 C Operating Humidity 85 RH under 68 F 20 C Remote Distance Up to 10 yards meters Remote Batteries 2 AA Alk...

Page 12: ...ll Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com December 13 2006 Model CS_u f...