OPERATION/SERVICE MANuAl

AP21

021020 /19125

RTC-TRAFFIC.COM

For Version 3.02 and higher.

Summary of Contents for AP21 Series

Page 1: ...OPERATION SERVICE Manual AP21 021020 19125 RTC TRAFFIC COM For Version 3 02 and higher ...

Page 2: ... 4 Display and Special Key Codes 5 Time Switch Keys 5 QUICK REFERENCE PROGRAMMING GUIDE Program Edit Time Of Day 6 Program Edit the Date 7 Program Edit the Day Of Week 7 Program Edit Daylight Saving Time 8 Program Edit Basic Program Steps 9 10 Program Edit Annual Plans 10 11 Activate Deactivate Sleep Mode 12 Program Edit Pulse Rate 12 Manual Operate the Output Relay 12 Adding Seconds to the Time D...

Page 3: ...ade up of the programmed steps that will take place on the assigned days and control the output relay The Day Plan can be assigned to all days just week days just weekends or specific days of the week 16 PROGRAM STEPS The Day Plan can hold up to 16 program steps The 16 program steps are used to program ON OFF times for the relay ANNUAL SKIP PLAN The AP21 can hold up to 10 Annual Skip Plans which a...

Page 4: ...COLOR TXDOT Wiring AP2T CPR FUNCTION 1 Black 120 VAC 2 White AC Neutral 3 Green Chassis Ground 4 Red Relay N O 5 Yellow Relay N O 6 N U N U 7 N U N U 8 N U N U 9 N U N U 10 White Yellow Relay Common 11 White Red 12V DC 12 White Black 12V DC Common 13 Black Red 12V DC 14 N U N U 15 Red 12V DC 16 N U N U PIN WIRE COLOR STANDARD Wiring AP2T CPR FUNCTION 1 Black White 120 VAC 2 White AC Neutral 3 Gree...

Page 5: ...ogramming mode and for stepping through the stored annual programs for review The annual programs contain the skip plans in calendar schedule form BASIC B KEY Used for entering the basic programming mode and for stepping through the stored basic programs for review The basic programs contain the daily timed events instructions CLEAR C KEY Used for clearing all annual skip plans and basic program s...

Page 6: ...w the display and enter the appropriate data as the cursor advances through the program entries You may exit this sequence if desired by pressing the EXIT key and the unit will default to the time display mode From the time display mode you may enter any of the set time date or program modes manually ENTERING DATA From the cursor you enter the appropriate data and press the ENTER key The cursor wi...

Page 7: ...g time change 45 Sleep Mode disables output relay 77 Clear all data for reprogramming 78 Program transfer between AP21 units 99 Current software version 88 Prevents the screen from blanking 88 again allows the screen to blank HH MM when Colon is Flashing Display Blanking when Colon is Steady Display ON continuously Time Switch Keys 1 AM and ON 2 PM 3 TIME time of day 4 DAY day of week 5 PULSE puls...

Page 8: ...e ENTER To Review Or Change The Time Of Day From the Time Display Mode Press TIME 3 and then press ENTER the cursor will be at the HOUR position Press ENTER if the HOUR displayed is correct or key in the correct HOUR and press ENTER the cursor will now advance to the MINUTE position Press ENTER if the MINUTE displayed is correct or key in the correct MINUTE and press ENTER the cursor will advance ...

Page 9: ...in the correct MONTH and press ENTER the cursor will now advance to the DAY position Press ENTER if the DAY displayed is correct or key in the correct DAY and press ENTER the cursor will advance to the YEAR position Press ENTER if the YEAR displayed is correct or key in the correct YEAR and press ENTER the display will return to the Time Display Mode To Review Or Change The Day Of Week From the Ti...

Page 10: ...ng month as 0 S D S T M M S U N F D S T M M S U N Note ENTER To Review Or Change Daylight Saving Time From the Time Display Mode Press DST 7 and then press ENTER SPRING DST will appear on the display Press ENTER if the MONTH displayed is correct or key in the correct MONTH and press ENTER the cursor will advance to the SUNDAY position NOTE To bypass the DST feature enter 00 and press ENTER Press E...

Page 11: ...isplayed is correct or key in the correct AM PM then press ENTER the display will advance to the ON OFF position Press ENTER if the ON OFF displayed is correct or toggle the ON or OFF then press ENTER the cursor will advance to the next program step number Repeat the programming process or press EXIT to return to the Time Display Mode To Review The Basic Program Steps From the Time Display Mode Pr...

Page 12: ...DD YY will be displayed Press ENTER if the month displayed is correct or key in the correct month then press ENTER the cursor will advance to the day position Press ENTER if the day displayed is correct or key in the correct day then press the ENTER the cursor will advance to the year position Press ENTER if the year displayed is correct or key in the correct year then press the ENTER the display ...

Page 13: ...ANNUAL A and then press ENTER Key in specific ANNUAL plan number to be cleared then press ENTER Key in 00 zero zero for the month then press ENTER the ANNUAL plan is cleared and the display returns to 00 Key in another ANNUAL PLAN number to be cleared or press EXIT to return to the Time Display Mode To Review Annual Plan Program Steps Starting from the Time Display Mode Press ANNUAL A and then pre...

Page 14: ...AY Starting from the Time Display Mode ON To manually turn the AP21 relay on press 1 then ENTER the display will return to the Time Display Mode OFF To manually turn the AP21 relay OFF press 0 then ENTER the display will return to the Time Display Mode Transfer A Program FROM ONE AP21 TO ANOTHER Starting from the Time Display Mode Key in 78 then press ENTER on the AP21 the program will be transfer...

Page 15: ... shall deliver the defective product to RTC and RTC will repair or replace the product and return it to the customer at RTC s cost RTC will not be responsible for damage caused by electrical surges brownouts blackouts lightning or any other act of God or electrical event Product Exceptions Cellular Modem equipment carries the same warranty above except the term is for a period of two 2 years Exten...

Page 16: ... warranty Please ship your repairs freight prepaid to the dealer in your area or directly to RTC Manufacturing Inc 1016 Enterprise Place Arlington Texas 76001 If the customer end user ships directly to RTC shipping charges will be paid by RTC for repaired products returned to the customer end user via regular surface freight Overnight delivery must be requested in advance and will be billed to the...