background image

REV. 12-28-17

American Flame: E-Stop Gas Timer

Model:

 ESTOP1-0H

Description

  The E-Stop Gas Timer is an emergency shut-off, mechanical timer, and manual shut-off gas valve 

designed to be installed on the inlet side of a gas appliance to enable the user to control the time gas is allowed to flow 

to a gas appliance.  This is a mechanical timer (no batteries or power required) that has the ability to control gas flow for 

1-hour (60 minutes) using the ESTOP1-0H model or 2.5-hours (150 minutes) using the ESTOP2-5H model.  In addition, 

both models have an emergency shut-off (red knob) that enables the user to quickly and easily shut the gas completely 

OFF, should the need arise.  

The E-Stop Gas Timer body is 4-inches high x 2 

 -inches wide x 2 

⅛ -inches deep

 and can replace a manual shut-off 

valve and meet local code requirements as the accessible shut-off valve.  It can be use for multiple applications (indoor 

or outdoor) from gas fire pits, gas grills, gas logs, gas torch lights, etc., wherever a shut-off valve is a requirement or a 

specified by a customer.

Model:

 ESTOP2-5H

E-Stop Gas Timer

A F

A M E R I C A N    F L A M E

PUSH TO STOP
TURN TO START

OFF

TURN

PAST

20

40

60

MINUTES

E-STOP1-0

PUSH TO STOP
TURN TO START

OFF

0.5

HOURS

1.5

2

2.5

E-STOP2-5

TURN

PAST

Specifications

 

Pipe Size:  ½” NPT (2) inlets and (2) outlets 

 

 

Maximum Pressure:  ½” PSI

CSA Rated Capacity: 165,000 Btu/Hr at 1” Pressure Drop (NG) 

Ambient Temperature: 0°F to 175°F (79°C)

Timer Accuracy: 60 Min. +/- 15% or 2.5 Hrs.+/- 15% 

 

Inlets: Have fine mesh screens to filter any debris  

Multiple Mounting Holes: Uses  3/16-24 machine threads   

Designed For: Natural or LP Gas (no conversion required) 

CSA Certified: Tested to ANSI Z21.21; CSA 6.5

WARNING

•  Read these instructions carefully. Failure to follow these instructions completely could damage the product or cause 

a hazardous condition.

•  Check the ratings given in the instructions and on the product your installing to make sure the E-Stop Gas Timer is 

suitable for your application. See description below.

•  Installer must be a trained, experienced service technician or gas plumber.

•  After installation is complete, check out product operation as provided in these instructions.

Reviews: