RS Stock No. 730-0458

Instruction Manual

RS-1384

4 Input Data Logging Thermometer

FR

EN

IT

DE

ES

    

  

Summary of Contents for RS-1384

Page 1: ...RS Stock No 730 0458 Instruction Manual RS 1384 4 Input Data Logging Thermometer FR EN IT DE ES ...

Page 2: ... Description of Display 5 4 OPERATION INSTRUCTION 7 4 1 Setting the Meter 7 4 2 Setting the Thermocouple Type 9 4 3 Temperature Measurement 9 4 4 Maximum MAX Minimum MIN Recording Measurement 9 4 5 Manual Data Memory and Read Function Operation 10 4 6 Auto Datalogging Function Operation 10 4 7 Disable Auto Power off Function 11 5 MAINTENANCE 12 5 1 General Maintenance 12 5 2 Battery Replacement 12...

Page 3: ...tection provided by the meter may be impaired Environment conditions Altitude up to 2000 meters Relatively humidity 80 max Operation Ambient 0 to 50 C 32 to 122 F Features Isolated Input Protection of 350Vp p between any two inputs Highly accurate thermometer with thermocouple K J E T R S N L U B C types 4 input function T1 T2 T3 T4 temperature display Programmable Hi Lo alarm for 4 inputs Display...

Page 4: ...0 C 0 25 2 0 C 32 to 212 212 to 572 572 to 999 9 1000 to 2912 9 0 F 5 4 F 0 05 3 6 F 0 25 3 6 F N 0 to 999 9 1000 to 1300 0 1 1 0 C 0 2 1 0 C 32 to 999 9 1000 to 2372 0 1 1 8 F 0 2 1 8 F L 200 to 900 0 1 1 0 C 328 to 999 9 1000 to 1652 0 1 1 8 F 0 2 1 F U 0 to 600 0 1 1 0 C 32 to 999 9 1000 to 1112 0 1 1 8 F 0 2 1 F B 600 to 999 9 1000 to 1760 0 05 2 0 C 0 1 2 0 C 1112 to 1831 1832 to 3200 0 05 3 ...

Page 5: ...ttery Indication The is displayed when the battery voltage drops below the operating voltage Measurement Rate Once per 2 seconds Weight 405g 14 3oz batteries included Dimension 18 7 7 3 5 3 cm Operating Temperature and Humidity 0 to 50 C 32 to 122 F below 80 RH Storage Temperature and Humidity 10 to 60 C 14 to 140 F below 70 RH Accessories Instruction manual alkaline battery USB cable Software CD ...

Page 6: ...11 7 4 3 6 15 14 12 9 2 1 8 1 LCD Display 2 key Power on off control key 3 keys Setting keys 4 HOLD key Data hold function key press the HOLD key to hold data the H symbol is displayed press this key again to exit this function Press and hold down the HOLD key then press key to turn on the meter the symbol disappears and the auto power off function is disabled ...

Page 7: ...s TIME key to scroll through the display data and time 9 ALARM key Press ALARM key to enable or disable Alarm function 10 MEM key Manual data storage control key 11 SET key Press SET key to start or exit setup 12 READ key Manual data storage reading control key 13 T1 T2 T3 T4 Thermocouple inputs 14 USB interface jack 15 External Power adaptor input jack 3 2 Description of Display ALARM INTV m s d ...

Page 8: ...rement display Battery capacity indication Replace batteries indication NO Last manual data memory address number 01 99 M Manual data memory indication M indicates that data is stored in memory NO R Indicates the current manual data memory address block A M Auto datalogging indication A M indicates auto datalogging is in use Full Auto datalogging memory full indication The continuous datalogging h...

Page 9: ...e the Set clock and SET symbols are displayed c Press key to enter the real time setting mode the two year digits will flash d Press or key to set the year of the real time e Press key to store the year and select month f Press or key to set the month of the real time g Press key to store the month and select day h Press or key to set the day of the real time i Press key to store the day and selec...

Page 10: ...t values f Press key to store the offset value g Press SET key to exit this mode The temperature measurement plus the offset appears in the display Remember to set the offset to 0 0 when it is no longer needed The OFFSET symbol will disappear when the offset values all are 0 0 4 Auto Power Off Time setting a Press key to turn on the meter b Press SET key to enter the setting mode then press or key...

Page 11: ...type choices The currently selected thermocouple type blinks 3 Press or key to select the desired T1 T2 T3 or T4 4 Press or key until the thermocouple type you want appears on the display 5 Press key to store the thermocouple type Repeat procedures 3 to 5 to store individual thermocouple types for T1 T2 T3 and T4 6 Press TYPE key again to exit 4 3 Temperature Measurement 1 Press key to turn on the...

Page 12: ...ata mode please ensure any previous memory data is first downloaded to a PC a Press key to turn off the meter b Press and hold down MEM key then press key again to turn on the meter the CLr YES no M symbol is displayed c Press key to enter the clear auto datalogged data mode the CLr YES no AM symbol is displayed d Press or key to select YES the symbol is displayed flashing e Press key to clear the...

Page 13: ...ing on the user setting to save power consumption 1 Disable auto power off procedure a Press key to turn off the meter b Press and hold down HOLD key then press key to turn on the meter the auto power off function will be disabled and the auto power off symbol will disappear 2 Auto power off mode is enabled each time you turn on the meter and is automatically disabled in the follow modes a MAX MIN...

Page 14: ... before replacing the batteries 1 When operating the meter on batteries periodically check the battery level indicator to determine the remaining battery capacity The number of black segments decreases as the batteries are used up When the symbol display starts to flash accurate measurement is no longer possible Replace the batteries 2 Take care not to reverse the and polarity when inserting the b...

Page 15: ... EN 09 16 11 Version No 00 EN 13 6 SOFTWARE INSTALLATION AND OPERATION For the instructions please refer to the PDF software manual on the CD ROM Protocols Are enclosed within the content of CD ROM please refer to the CD ROM for details ...