background image

 

Ropox Puslebord Maxi 2     

 

Brugermanual 

Montagevejledning 

Denne manual skal altid ledsage produktet 

PDF 6082 / 17.06.2014 

 

Summary of Contents for Maxi 2 50-50670

Page 1: ...Ropox Puslebord Maxi 2 Brugermanual Montagevejledning Denne manual skal altid ledsage produktet PDF 6082 17 06 2014 ...

Page 2: ...ækkappe 10 3 Montage af øverste dækkappe 10 4 Montage af bordplade 11 5 Tilslutning af sikkerhedskreds 12 6 Tilslutning af vand og afløb 13 6 Tilslutning af vand og afløb 14 Ledningsdiagram 15 Forbindelser 16 Afmontering 16 Mærkning 17 Label 17 Symboloversigt 17 Support 18 Fejlfinding 18 Affaldshåndtering 18 Faktorer som påvirker produktet ved oplagring og transport 18 Servicering 19 Reservedele 2...

Page 3: ...g Puslebordet kan benyttes i private hjem daginstitutioner eller tilsvarende institutioner for at sikre korrekte og optimale arbejdsforhold for personalet brugeren Højdeindstillingen udføres ved at trykke på op og ned knapperne på håndbetjeningen Varenumre Længde af puslebord Varenr 90cm 50 50672 130cm 50 50670 Det er vigtigt at læse denne manual inden montage og ibrugtagning Puslebord Maxi 2 90 c...

Page 4: ...vet og EMC direktivet Det er testet i henhold til de europæiske standarder DS EN ISO 12182 og DS EN ISO 60335 Daglig brug Inden ibrugtagning af dette produkt er det vigtigt at hovedstrømmen er tilsluttet som beskrevet under elektriske forbindelser Højden af puslebordet justeres ved at trykke på op og ned tasterne på håndbetjeningen Maks belastning på puslebordet 75kg Advarsel Når puslebordet højde...

Page 5: ...ingen børn leger under eller med puslebordet Vær opmærksom på at de ikke uforvarende kan komme til at betjene puslebordet Sørg for at der er fri plads over og under puslebordet for at tillade fri bevægelse ved højdeindstilling Vær opmærksom på at der ikke er forhindringer over under eller rundt om puslebordet for at undgå klemningsfare ved højdejustering af bordet Hvis håndbetjeningen er beskadige...

Page 6: ...uligt placeres ud fra placeringen på ovenstående skitse Længden på netledningen er 3 2 m Ledningen er uden jord da styringen er dobbeltisoleret Advarsel Når puslebordet højdejusteres er der risiko for klemning mellem bord og tilstødende genstande Før puslebordet anvendes skal brugeren sikre sig at der ikke er forhindringer som skal hindre bordets bevægelse Produktet må IKKE betjenes af børn Pusleb...

Page 7: ...ord Målskitse Til denne montagevejledning medfølger Løfteunit x1 Montageskruer x7 Dækkappe for løfteunit x1 Rawplugs x7 Bordplade x1 Bolt M5 x 25 x6 Dækkapper x3 Bolt M4 x 10 x9 Sikkerhedsplade x1 Bolt M8 x 20 x2 Afløbsslange x1 Kabel sikkerhedsstop x1 ...

Page 8: ...Side 8 Montagevejledning 1 Montage til væggen ...

Page 9: ...Side 9 Montagevejledning ...

Page 10: ...Side 10 Montagevejledning 2 Montage af nederste dækkappe 3 Montage af øverste dækkappe ...

Page 11: ...Side 11 Montagevejledning 4 Montage af bordplade ...

Page 12: ...Side 12 Montagevejledning 5 Tilslutning af sikkerhedskreds ...

Page 13: ...Side 13 Montagevejledning 6 Tilslutning af vand og afløb ...

Page 14: ...Side 14 Montagevejledning 6 Tilslutning af vand og afløb ...

Page 15: ... montere afmontere Sørg for at alle stik vender korrekt inden de stikkes ind i kontrolboksen Stikkene skal trykkes ind indtil O ringen ikke længere er synlig Motor kontrolboks og håndbetjening har tæthedsgrad IPX6 Det elektriske system er designet til periodisk brug hvilket betyder en maks intermittens på 10 2min til 18min fra 1 Kontrolboks 2 Netkabel 230V 3 Motor tilsluttes indgang 1 4 Håndbetjen...

Page 16: ...dgang 1 Indgang 2 3 4 benyttes ikke og er derfor blændet med blindprop Håndbetjening tilsluttes indgang HB Netkablet forbindes til indgangen placeret på siden af kontrolboksen Afmontering Netkablet kan trækkes direkte ud For at opretholde den fulde IPX6 tæthedsgrad er det meget vigtigt at alle kabelforbindelser er udført korrekt ...

Page 17: ...e CE mærkning Dette produkt opfylder kravene til General Safety and Functionality i de relevante EU direktiver og standarder EMC information Puslebordet opfylder kravene til Electromagnetic Compatibility EMC såfremt montage og daglig brug er i overensstemmelse med instruktionerne i denne manual I sjældne tilfælde kan puslebordet blive påvirket af elektroniske signaler fra f eks bærbare computere m...

Page 18: ... brugte udstyr skal bortskaffes i henhold den nationale lovgivning Vi anbefaler at adskille produktet mest muligt således at så meget som muligt kan genbruges Vær opmærksom på at dette produkt indeholder elektriske komponenter Eksempel på grupper som dette produkt kan sorteres i Metal plastik kabler elektronik og dele til destruktion Puslebordet kan anvendes i temperaturer mellem 5 C til 45 C Pusl...

Page 19: ...ælde af fejl eller mangler bedes Ropox kontaktes hurtigst muligt Indtil dette er løst udbedret må puslebordet ikke anvendes Hvis man ikke selv vil stå for denne gennemgang kan Ropox kontaktes for at aftale et besøg af en servicetekniker Se kontaktoplysninger sidst i denne manual i Vedligeholdelse af puslebordet må kun udføres af fagpersonale ...

Page 20: ...Side 20 Reservedele Gængse reservedele 97000420 Aktuator Type LA31 3 Slaglængde 300 mm 97000434 Kontrolboks Type CB9096 2 97000244 Ropox Håndbetjening ...

Page 21: ...øjtryksrenser til rengøring af dette produkt Der anvendes blot en blød klud eller svamp med almindeligt maks 60 C varmt sæbevand pH 7 eller husholdningssprit Rengør altid puslebordet efter brug for at forhindre snavs i at sætte sig fast på overfladerne Vigtigt Benyt ikke skurepulver eller andre slibende midler da de vil ridse overfladerne Benyt heller ikke spidse eller skarpe rengøringsredskaber S...

Page 22: ...r DIREKTIVER Rådets Direktiv nr 89 392 EØF vedrørende Maskiner ændret ved Direktiv nr 98 37 EF 2006 95 EØF Lavspændingsdirektivet ændret ved direktiv nr 93 68 EEC 2004 108 EØF EMC direktivet ændret ved direktiv nr 92 31 EØF og 93 68 EØF DS EN 12221 1 2008 Børneomsorgsprodukter Pusleborde til privat brug Del 1 Sikkerhedskrav STANDARDER DS EN 1041 2009 DS EN ISO 60335 1 DS EN 14971 2008 DS EN 12221 ...

Page 23: ...DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox de Ropox A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox com Ropox A S Ringstedgade 221 DK 4700 Næstved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox dk ...

Page 24: ...Side 24 Ropox Nursing table Maxi 2 Usermanual Mounting Instruction This manual need to follow the product PDF 6082 17 06 2014 ...

Page 25: ...ketch 30 1 Mounting to the wall 31 2 Mounting of the lower cover 33 3 Mounting of the upper cover 33 4 Connection of the worktop 34 5 Connection of the safety stop 35 6 Connection of water and drain 36 Wiring circuit 38 Connections 39 Dismounting 39 Labelling 40 Label 40 Symbols 40 Support 41 Troubleshooting 41 Waste 41 Factors affecting the product during storage and transport 41 Performance test...

Page 26: ...nursing table can be used I private homes daycare centers or similar institutions to ensure correct and optimal working conditions for staff The height adjustment is performed by pressing the up and down buttons on the handset Item number Lenght of the nursing table Part no 90cm 50 50672 130cm 50 50670 It is important to read this manual before mounting and use of the nursing table Nursing table M...

Page 27: ...d EMC Directives It has been tested according to European standards DS EN ISO 12182 and DS EN ISO the 60335th Daily use Before using this product it is important that the main power is applied as described under electrical connections The height of the nursing table is adjusted by pressing the up and down buttons on the handset Max load on the nursing table 75kg Warning During height adjustment of...

Page 28: ...ake sure that no children are playing under or with the table Make sure that children cannot operate the nursing table unintentionally See that there is free space above and below the table to allow height adjustment Make sure that there are no obstacles above below or around the nursing table in order to avoid the risk of getting jammed during height adjustment If the handset is damaged or does n...

Page 29: ...f the nursing table as shown below Placement of 230V socket hot and cold water and drain If possible socket for 230V and drain and connection for hot and cold water should be located as shown on the above sketch The length of the mains cable is 3 2 m Nursing table Maxi 2 90 cm Nursing table maxi 2 130 cm 70 cm 70 cm ...

Page 30: ...Dimension sketch These mounting instructions comprise Lifting unit x1 Mounting screws x7 Covers for the lifting unit x1 Rawlplugs x7 Worktop x1 Bolts M5 x 25 x6 Bolt M4 x 10 x9 Safety plate x1 Bolts M8 x 20 x2 Drain and water hose kit x1 Cable Safety stop x1 ...

Page 31: ...Side 31 Mounting instruction 1 Mounting to the wall ...

Page 32: ...Side 32 Mounting instruction ...

Page 33: ...Side 33 Mounting instruction 2 Mounting of the lower cover 3 Mounting of the upper cover ...

Page 34: ...Side 34 Mounting instruction 4 Connection of the worktop 5 Mounting of the worktop ...

Page 35: ...Side 35 Mounting Instruction 5 Connection of the safety stop ...

Page 36: ...Side 36 Mounting Instruction 6 Connection of water and drain ...

Page 37: ...Side 37 Mounting Instruction ...

Page 38: ...difficult Make sure that all plugs have the correct position before inserting them into the control unit The plugs must be pressed home until the O ring is no longer visible Motor and control box has an IPX6 rating This means that they are dust and waterproof The electrical system is designed for intermittent use which means a maximum duty cycle of 10 2min on 18min from 6 Controlbox 7 Mains cable ...

Page 39: ...1 Ports 2 3 4 are not used and are therefore provided by blind plug Handset must be connected to HB The mains cable must be connected to the port on the side of the control box Dismounting Just pull out the mains cable In order to maintain the full IPX6 protection class it is very important that all cables have been mounted correctly ...

Page 40: ...oduct meets the requirements for General Safety and Functionality of the current EU Directives and Standards EMC information The nursing table meets the requirements for Electromagnetic Compatibility EMC if installation and daily use are in accordance with the instructions in this manual On rare occasions the nursing table can be affected by electronic signals from e g laptops mobile phones or the...

Page 41: ...opox for support Waste The used equipment must be disposed of in accordance with national law We recommend disassembling of the product to the greatest possible extent so that most parts may be recycled Please note that this product contains electrical components Examples of sorting groups Metal plastic cables electronics and parts for destruction The nursing table may be used at temperatures from...

Page 42: ...d nuts once a year In case of defects please contact Ropox as soon as possible and do not use the nursing table until the problem has been solved remedied If you do not want to carry out this performance test yourself contact Ropox to arrange a visit by a service technician See contact information at the end of this manual i ...

Page 43: ...Side 43 Spare parts 97000420 Actuator Type LA31 3 Stroke 300 mm 97000434 Controlbox Type CB9096 2 97000244 Control switch ...

Page 44: ...essure washer to clean this product Simply use a soft cloth or sponge with soapy water of max 60 C pH 7 or cleaning alcohol Always clean the nursing table after use to prevent dirt from sticking to the surfaces IMPORTANT Do not use scouring powders or other abrasives as they will scratch the surface Also avoid the use of cleaning utensils with sharp edges Never use strong mineral acids or alkaline...

Page 45: ...nd standards DIRECTIVES Council Directive No 89 392 EEC concerning Machinery amended by Directive No 98 37 EC 2006 95 EU Low Voltage directive amended by directive No 93 68 EEC 2004 108 EU EMC directive amended by directive No 92 31 EEC and 93 68 EEC DS EN 12221 1 2008 Products for child care nursing tables for private use Part 1 Safety requirements STANDARDS DS EN 1041 2009 DS EN ISO 60335 1 DS E...

Page 46: ...ved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox de Ropox A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox com Ropox A S Ringstedgade 221 DK 4700 Næstved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox dk ...

Page 47: ...Side 47 Ropox Wickeltisch Maxi 2 Benutzerhandbuch Montageanleitung Verbleibt beim Produkt PDF 6082 17 06 2014 ...

Page 48: ...ge 54 2 Montage der unteren Abdeckung 56 3 Montage der oberen Abdeckung 56 4 Montage der Tischplatte 57 5 Anschluss des Sicherheitskreises 58 6 Anschluss von Wasser und Ablauf 59 Schaltdiagramm 61 Anschlüsse 62 Demontage 62 Kennzeichnung 63 Label 63 Symbole 63 Support 64 Fehlersuche 64 Abfallentsorgung 64 Faktoren die bei Lagerung und Transport auf das Produkt einwirken 64 Funktionsprüfung 65 Ersa...

Page 49: ...mmt in Privatwohnungen Tageszentren oder ähnlichen Institutionen zum Einsatz zur Erreichung der korrekten und optimalen Arbeitsverhältnisse für das Personal den Benutzer Die Höhenverstellung erfolgt durch Drücken der Auf und Abwärtstaster der Handbedieneinheit Warennummern Länge des Wickeltisches Warennummer 90cm 50 50672 130cm 50 50670 Immer dieses Handbuch vor Montage und Ingebrauchnahme durchle...

Page 50: ...tlinie Es ist gemäß den europäischen Normen DS EN ISO 12182 und DS EN ISO 60335 geprüft worden Täglicher Gebrauch Vor Ingebrauchnahme des Produktes immer die Netzspannung wie unter elektrischen Anschlüssen beschrieben einschalten Die Höhe des Wickeltisches wird durch Drücken der Aufwärts und Abwärtstaster der Handbedieneinheit verstellt Max Belastbarkeit des Wickeltisches 75kg Warnung Bei Höhenver...

Page 51: ...sein Kinder dürfen nicht mit oder unter dem Tisch spielen Sicherstellen dass Kinder nicht unbeabsichtigt den Wickeltisch betätigen können Sicherstellen dass über und unter dem Wickeltisch für die Höhenverstellung freier Raum vorhanden ist und dass sich keine Hindernisse über unter oder um den Wickeltisch befinden um bei Höhenverstellung Klemmgefahr zu vermeiden Ist die Handbedieneinheit beschädigt...

Page 52: ...h wie auf der obenstehenden Skizze gezeigt angeordnet werden Die Länge des Netzkabels beträgt 3 2 m Das Kabel hat keine Erdverbindung da die Steuereinheit doppelisoliert ist Warnung Bei Höhenverstellung des Wickeltisches besteht Klemmgefahr zwischen dem Tisch und benachbarten Gegenständen Vor Bedienung des Wickeltisches muss sichergestellt werden dass keine Gegenstände die Bewegung des Tisches hin...

Page 53: ...kizze Zu dieser Montageanleitung gehören Hebeeinheit x1 Montageschrauben x7 Abdeckung für Hebeeinheit x1 Dübel x7 Tischplatte x1 Bolzen M5 x 25 x6 Abdeckungen x3 Bolzen M4 x 10 x9 Sicherheitsplatte x1 Bolzen M8 x 20 x2 Ablaufschlauch x1 Kabel Sicherheitsstop x1 ...

Page 54: ...Side 54 Montageanleitung 1 Wandmontage ...

Page 55: ...Side 55 Montageanleitung ...

Page 56: ...Side 56 Montageanleitung 2 Montage der unteren Abdeckung 3 Montage der obereaf øverste dækkappe ...

Page 57: ...Side 57 Montagevejledning 4 Montage der Tischplatte ...

Page 58: ...Side 58 Montageanleitung 5 Anschluss des Sicherheitskreises ...

Page 59: ...Side 59 Montageanleitung 6 Anschluss von Wasser und Ablauf ...

Page 60: ...Side 60 Montageanleitung 6 Anschluss von Wasser und Ablauf ...

Page 61: ...schen erschwert werden Die Position der Stecker vor Einstecken in der Steuereinheit überprüfen Die Stecker so eindrücken dass der O Ring nicht länger sichtbar ist Motor Steuereinheit und Handbedieneinheit haben Schutzart IPX6 Das elektrische System ist für periodischen Gebrauch vorgesehen d h eine maximale Einschaltdauer von 10 2Min EIN 18Min AUS 11 Steuereinheit 12 Netzkabel 230V 13 Motor Anschlu...

Page 62: ...inden Eingang 2 3 4 werden nicht benutzt und sind deshalb mit Blindstopfen versehen Handbedieneinheit an Eingang HB verbinden Netzkabel an den Eingang auf der Seite der Steuereinheit verbinden Demontage Das Netzkabel kann direkt gezogen werden Zur Aufrechterhaltung der vollen IPX6 Schutzart müssen alle Kabelverbindungen korrekt montiert sein ...

Page 63: ... den Anforderungen an General Safety and Functionality der betreffenden EU Richtlinien und Normen EMC Information Der Wickeltisch entspricht den Anforderungen betreffend Electromagnetic Compatibility EMC vorausgesetzt dass die Montage und der tägliche Gebrauch gemäß diesen Anleitungen erfolgen In seltenen Fällen können elektronische Signale von z B Laptops Handys o dgl auf den Wickeltisch einwirke...

Page 64: ...t Abfallentsorgung Die gebrauchte Ausstattung muss gemäß nationaler Gesetzgebung entsorgt werden Wir empfehlen Zerlegung des Produktes damit möglichst viele Teile wieder verwendet werden können Beachten dass dieses Produkt elektrische Komponenten enthält Beispiel für Sortierungsgruppen Metall Plastik Kabel Elektronik und Teile zur Verschrottung Der Wickeltisch kann bei Temperaturen zwischen 5 C un...

Page 65: ... bald mit Ropox Kontakt aufnahmen Der Wickeltisch darf erst nach Abhilfe des Problems wieder benutzt werden Wünscht man nicht die Funktionsprüfung selber durchzuführen kann mit Ropox der Besuch eines Servicetechnikers verabredet werden Siehe Kontaktinformationen am Ende dieses Handbuches i Die Wartung des Wickeltisches darf nur von kompetentem Fachpersonal durchgeführt werden ...

Page 66: ...Side 66 Ersatzteile Übliche Ersatzteile 97000420 Aktuator Typ LA31 3 Hublänge 300 mm 97000434 Steuereinheit Typ CB9096 2 97000244 Ropox Handbedieneinheit ...

Page 67: ...es einen Hochdruckreiniger benutzen Einfach einen weichen Lappen oder Schwamm mit Seifenwasser von höchstens 60 C pH 7 oder Haushaltsspiritus verwenden Immer den Wickeltisch nach Gebrauch reinigen damit sich auf den Oberflächen kein Schmutz festsetzt Wichtig Kein Scheuerpulver oder andere schleifende Produkte verwenden um Risse in den Oberflächen zu vermeiden Auch keine spitzen oder scharfen Reini...

Page 68: ...ichtlinie des Rates Nr 89 392 EWG über Maschinen abgeändert durch Richtlinie Nr 98 37 EG 2006 95 EWG Niederspannungsrichtlinie abgeändert durch Richtlinie Nr 93 68 EWG 2004 108 EWG EMC Richtlinie abgeändert durch Richtlinie Nr 92 31 EWG und 93 68 EWG DS EN 12221 1 2008 Kinderpflegeprodukte Wickeltische für privaten Gebrauch Teil 1 Sicherheitsanforderungen NORMEN DS EN 1041 2009 DS EN ISO 60335 1 D...

Page 69: ...DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox de Ropox A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox com Ropox A S Ringstedgade 221 DK 4700 Næstved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox dk ...

Reviews: