background image

 

 

 

7/04/2017 

 

 

Manufactured By 

ROBAND AUSTRALIA PTY LTD

 

 

OPERATING INSTRUCTIONS 

BAIN MARIES 

Models:

 BM14, BM15, BM16, BM22, BM23, BM24, BM25 & BM26  

Version 1 & 2 

 

Special Features: 

  Ultra-Durable Stainless Steel Elements 

  Designed to take many combinations of pans 

  Wet or Dry Operation 

  Thermometer Display 

 

 

These instructions cover the models of  ROBAND

®

 Bain Maries listed above only.  Although there 

are slight variances between models, the installation, operation, care and maintenance procedure 
is the same for all. 

 

Summary of Contents for BAIN MARIES BM14A

Page 1: ...Special Features Ultra Durable Stainless Steel Elements Designed to take many combinations of pans Wet or Dry Operation Thermometer Display These instructions cover the models of ROBAND Bain Maries li...

Page 2: ...without the written permission of the publisher The material contained within this document is intended entirely for instructional purposes Roband Head Office Sydney Australia Roband Australia Pty Ltd...

Page 3: ...NTS INTRODUCTION 1 GENERAL PRECAUTIONS 1 PACKAGING 2 COMPLIANCE 2 INSTALLATION 3 GENERAL SAFETY 5 CLEANING CARE MAINTENANCE 6 TROUBLESHOOTING 7 SPECIFICATIONS 8 CIRCUIT DIAGRAM 9 APPENDIX A 10 WARRANT...

Page 4: ...cal sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsible for their...

Page 5: ...the Freight Company and to the agent responsible for the dispatch of said unit within 24 hours of receipt No claims will be accepted or entertained after this period RCM Roband products have been desi...

Page 6: ...is task Before connecting the Bain Marie to the power supply ensure that all the controls are in the OFF position Plug the machine into a power outlet matching the plug type supplied National Standard...

Page 7: ...WET OPERATION For wet operation the most important factor is the volume of water placed in the tank The tank should be filled with fresh clean water to a level where it just touches the bottom of the...

Page 8: ...is unit can get very hot ensure everyone is aware that the machine is operating and take care to avoid contact with hot surfaces National Standards exist outlining the positioning spacing and ventilat...

Page 9: ...ife of the element and tank Do not use a metal scourer In some areas hard water may cause a residue to build up on the surface of the tank and element This should be removed to prevent any corrosion t...

Page 10: ...plugged in correctly and the power id switched on The power point is not faulty The thermostat is not in the OFF position The Thermostat knob is not loose or broken rendering the thermostat inoperabl...

Page 11: ...220 240 Volts AC 50 60Hz 1680 2000 Watts 1665 408 255 BM22 220 240 Volts AC 50 60Hz 1100 1300 Watts 705 615 255 BM23 220 240 Volts AC 50 60Hz 1680 2000 Watts 1030 615 255 BM24 220 240 Volts AC 50 60H...

Page 12: ...16 BM22 BM23 BM25 BM26 NOTE This circuit diagram has been provided for reference and to assist qualified service and repair agents only Under no circumstances should person s not suitably qualified at...

Page 13: ...should be taken to ensure that the sum of the leakage currents of electrical equipment on the load side of an RCD is less than 1 3 of its rated residual current To avoid excessive leakage current caus...

Page 14: ...Page 11 NOTES...

Page 15: ...ve goods or materials pursuant to this warranty must be authorized by Roband Australia prior to any action being taken The company reserves the right to reject a claim for warranty if it is not comple...

Page 16: ...ER LEADING PRODUCTS AVAILABLE Sycloid Toaster DRINK MIXERS HIGH PERFORMANCE DEEP FRYERS VITAMIX BLENDERS GRILLMAX TOASTERS NOAW Slicers Manufactured Imported in Australia by Authorised Distributor Age...

Reviews: