IMCB10-E1

Limit Controller

CB100L/CB900L

Initial Setting Manual

RKC INSTRUMENT INC.

®

Summary of Contents for CB100L

Page 1: ...IMCB10 E1 Limit Controller CB100L CB900L Initial Setting Manual RKC INSTRUMENT INC ...

Page 2: ...copied in whole or in part without RKC s prior consent z This instrument and manual are manufactured prepared then shipped under strict quality control However if any defect is found please contact your nearest RKC sales office or agent from which you bought the system z RKC assumes no responsibility for any of the following damage which the user or third party may suffer 1 Damage incurred as a re...

Page 3: ...event electric shock or instrument failure do not turn on the power supply until all of the wiring is completed NEVER USE THE INSTRUMENT NEAR FLAMMABLE GASES In order to prevent fire explosion or instrument damage never use this instrument at a location where flammable or explosive gases or vapor exist NEVER TOUCH THE INSIDE OF THE INSTRUMENT In order to prevent electric shock or burns never touch...

Page 4: ...strument check that the power is turned off z Remove stains on the display unit using a soft cloth or tissue paper z As the display unit is easily scratched do not scrub or touch it with a hard object z The stains on the housing shall be wiped off by the cloth which is dipped into the neutral cleanser diluted by water and wrung tightly and finish it by a dried cloth This is a Class A EN55022 instr...

Page 5: ...umber of this instruction manual Name Limit Controller CB100L CB900L Initial Setting Manual Manual number IMCB10 E1 Revisions Date of revision Manual number Reason for revision October 5 1998 IMCB10 E1 The first edition issue ...

Page 6: ...1 Display flowcharts in initialization mode 4 2 2 Procedure for setting each parameter 5 2 3 Details of parameters in initialize code 0 Cod 0 7 2 4 Details of parameters in initialize code 1 Cod 1 12 2 5 Details of parameters in initialize code 2 Cod 2 18 3 COMMUNICATION INITIALIZE IDENTIFIER 19 List of communication initialize identifiers 19 ...

Page 7: ...ng mode For details on parameter setting mode see the CB100L CB900L Instruction Manual IMCB08 E e Press the SET key to change to the set data lock function display screen f Press the RST key to light brightly the thousands digit on the set value SV display unit g Press the UP key to change 0 to 1 in the thousands digit RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT EXCD RST ...

Page 8: ... displayed first z The initialization mode can be selected anytime when PV SV SV setting peak hold value or over time is displayed z If the controller is change to initialization mode both limit and alarm outputs contact are set to the open state and the analog output to 5 RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT EXCD RST RST RST RST SET SET SET SET SV SV SV SV PV PV P...

Page 9: ... the numeric value corresponding to the thousands digit to 0 from 1 i Press the SET key to transfer to the next parameter As a result the Initialization mode lock state setting becomes effective After the controller terminates the initialization mode the limit action output is set to the ON state in the same way as at the time of power ON RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM...

Page 10: ...essing the SET and RST keys simultaneously for 2 sec with the set data unlocked Explaining the arrow mark Press the SET and RST keys simultaneously for 2 sec Press the SET key Set to 0 Input type selection Engineering unit selection Action selection at the time of reset key operation Alarm 1 type selection Alarm 2 type selection Limit action type selection Special specification selection 1 Special...

Page 11: ...e group of initialize code 0 do not change the initialize code the units digit but press the SET key to change to SL6 When the initialize code is set to 1 or 2 enter 1 or 2 in the units digit of the set value SV display unit by pressing the UP or DOWN key RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT EXCD RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT...

Page 12: ... 1 in the hundreds digit of the set value SV display unit g Press the SET key to change to the next parameter Thus the set value is registered RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT EXCD RST RST RST RST SET SET SET SET SV SV SV SV PV PV PV PV ALM2 ALM1 OUT EXCD Bright lighting Dim lighting Limit action type selection Special specification selection 1 Set value 0 Limi...

Page 13: ... Thermocouple input TC 1 1 0 0 Pt100 Ω JIS IEC 1 1 0 1 JPt100 Ω JIS RTD input 1 1 1 0 0 to 5V DC 1 1 1 0 0 to 10V DC 1 Voltage input 1 1 1 1 1 to 5V DC 1 1 1 0 0 to 20 mA DC 1 1 1 1 4 to 20 mA DC Current input 2 1 To be fixed to 1110 for the 0 to 10 V DC Z 1010 specification No input type cannot be changed as the hardware differs 2 For the current input specification a resistor of 250 Ω must be co...

Page 14: ...o not change any of these digits Factory set value 0000 Set value Description 0 0 Reset action taken and all data items cleared 1 Selects the action on 0 1 Reset action taken and each data items cleared 2 each screen at the 1 0 Reset action taken and each data items cleared 3 of reset key 1 1 Reset action taken and each data items cleared 4 0 0 Fixed All data items Peak hold value and over time 1 ...

Page 15: ...Process low alarm 0 Without alarm hold action Alarm 1 ALM1 with hold action 1 With alarm hold action selection 5 SL5 Alarm 2 type selection Instrument without the alarm 2 ALM2 is set to 0000 Factory set value varies depending on the instrument specification Set value Description 0 0 0 Alarm 2 ALM2 not provided Alarm 2 ALM2 type selection 0 0 1 Deviation high alarm 0 1 0 Deviation high low alarm 0 ...

Page 16: ... 0000 yInstrument without the alarm 1 ALM1 SL4 setting details For 0000 yInstrument without the alarm 2 ALM2 SL5 setting details For 0000 Factory set value 1100 Set value Description 0 Energize alarm Energize alarm de energize 1 De energize alarm selection Alarm 1 side 0 Energize alarm Energize alarm de energize 1 De energize alarm selection Alarm 2 side 0 Z 124 specification not provided 1 Specia...

Page 17: ...unction is activated 9 SL9 Unused SL9 is not used Only displayed Displayed value 0000 fixed 10 SL10 Option selection The thousands digit is not used As malfunction may result do not change this digit Factory set value varies depending on the instrument specification Set value Description 0 Analog output not provided Selection of analog output 1 Analog output provided function 0 Contact input not p...

Page 18: ...F S 0 to 1769 C 0 to 3216 F B 0 to 1820 C 0 to 3308 F E 0 to 1000 C 0 to 1832 F N 0 to 1300 C 0 to 2372 F T 199 9 to 400 0 C 199 9 to 752 0 F W5Re W26Re 0 to 2320 C 0 to 4208 F PL II 0 to 1390 C 0 to 2534 F U 199 9 to 600 0 C 199 9 to 999 9 F Thermocouple input TC L 0 to 900 C 0 to 1652 F Pt100 Ω JIS IEC 1 199 9 to 649 0 C 199 9 to 999 9 F RTD input JPt100 Ω JIS 199 9 to 649 0 C 199 9 to 999 9 F 0...

Page 19: ... 1832 F N 0 to 1300 C 0 to 2372 F T 199 9 to 400 0 C 199 9 to 752 0 F W5Re W26Re 0 to 2320 C 0 to 4208 F PL II 0 to 1390 C 0 to 2534 F U 199 9 to 600 0 C 199 9 to 999 9 F Thermocouple input TC L 0 to 900 C 0 to 1652 F Pt100 Ω JIS IEC 1 199 9 to 649 0 C 199 9 to 999 9 F RTD input JPt100 Ω JIS 199 9 to 649 0 C 199 9 to 999 9 F 0 to 5 V DC 1999 to 9999 Voltage input 0 to 10 V DC 2 programmable scale ...

Page 20: ... 0 to 200 0 C J 0 to 200 C T 0 0 to 350 0 C J 0 to 400 C T 2 199 9 to 752 0 F J 0 to 600 C T 100 0 to 200 0 F J 0 to 800 C T 100 0 to 400 0 F J 0 to 1000 C T 0 0 to 450 0 F J 0 to 1200 C T 0 0 to 752 0 F J 0 to 450 C W5Re W26Re 0 to 2000 C J 0 to 800 F W5Re W26Re 0 to 2320 C J 0 to 1600 F W5Re W26Re 0 to 4000 F J 0 to 2192 F PL II 0 to 1300 C J 0 to 400 F PL II 0 to 1390 C J 0 to 300 F PL II 0 to ...

Page 21: ...S IEC 0 0 to 100 0 C Pt100 JIS IEC 0 0 to 200 0 C Pt100 JIS IEC 0 0 to 300 0 C Pt100 JIS IEC 0 0 to 500 0 C Pt100 JIS IEC 199 9 to 999 9 F Pt100 JIS IEC 199 9 to 400 0 F Pt100 JIS IEC 199 9 to 200 0 F Pt100 JIS IEC 100 0 to 100 0 F Pt100 JIS IEC 100 0 to 300 0 F Pt100 JIS IEC 0 0 to 100 0 F Pt100 JIS IEC 0 0 to 200 0 F Pt100 JIS IEC 0 0 to 400 0 F Pt100 JIS IEC 0 0 to 500 0 F JPt100 JIS 199 9 to 6...

Page 22: ... to 5 V DC 0 0 to 100 0 For the 0 to 10 V DC Z 1010 specification no input type cannot be changed as the hardware differs f f f fCurrent input Type Input range 0 to 20 mA DC 4 to 20 mA DC 0 0 to 100 0 For the current input specification a resistor of 250 Ω must be connected between the input terminals ...

Page 23: ...3 3 digit below decimal point 0 0 0 Fixed 4 AH1 Differential gap setting of alarm 1 ALM1 Not displayed when there is no alarm 1 ALM1 SL4 setting 0000 Setting range c TC and RTD inputs 0 to 100 or 0 0 to 100 0 d Voltage and current inputs 0 0 to 10 0 of span Factory set value c TC and RTD inputs 2 or 2 0 d Voltage and current inputs 0 2 5 AH2 Differential gap setting of alarm 2 ALM2 Not displayed w...

Page 24: ...range 0000 to 0010 Operating time from 0 to 100 000 hours can be displayed for both the upper and lower digits Display resolution 10 000 hours 3 WTL Operating time display unit Lower digits The integrated value lower 4 digits of power ON time is shown on the set value SV display unit If the total operating time exceeds 9 999 hours these digits move to the operating time display unit Upper digits W...

Page 25: ...ode Cod IP 0 to 2 0 R W Input type selection SL1 XI 0 to 15 See 1 According to input type R W Engineering unit selection SL2 XQ 0 C 1 F 0 R W Action selection at the time of reset key operation SL3 LV 0 to 3 See 2 0 R W Alarm 1 ALM1 type selection SL4 XA 0 to 15 See 3 1 R W Alarm 2 ALM2 type selection SL5 XB Limit action type selection SL6 CA 0 to 14 See 4 0 R W Special specification selection 1 S...

Page 26: ...ntial gap setting of alarm 2 ALM2 AH2 HB Holding peak ambient temperature TCJ Hp 10 to 100 C 0 RO Operating time display unit Upper digits WTH UT 0 to 10 0 RO Operating time display unit Lower digits WTL UU 0 to 9999 0 RO ID Identifier Factory set value 1 List of input type selection Input type Setting range Set value K 0 to 1372 C 0 to 2502 F 0 J 0 to 1200 C 0 to 2192 F 1 L 0 to 900 C 0 to 1652 F...

Page 27: ... 7 Process low alarm 1 Deviation high alarm 9 Deviation high alarm with hold action 2 Deviation high low alarm 10 Deviation high low alarm with hold action 3 Process high alarm 11 Process high alarm with hold action 5 Deviation low alarm 13 Deviation low alarm with hold action 6 Band alarm 15 Process low alarm with hold action Do not set 4 8 12 or 14 Malfunction may result 4 0 Limit action high li...

Page 28: ...provided 11 Alarm 1 De energized alarm Alarm 2 De energized alarm Z 124 specification provided 12 Alarm 1 Energized alarm Z 124 specification provided Alarm 2 Energized alarm Z 124 specification provided 13 Alarm 1 De energized alarm Z 124 specification provided Alarm 2 Energized alarm Z 124 specification provided 14 Alarm 1 Energized alarm Z 124 specification provided Alarm 2 De energized alarm Z...

Page 29: ...All Rights Reserved Copyright 1998 RKC INSTRUMENT INC ...

Page 30: ...IMCB10 E1 OCT 1998 RKC INSTRUMENT INC HEAD OFFICE 16 6 KUGAHARA 5 CHOME OHTA KU TOKYO 146 8515 JAPAN PHONE 03 3751 9799 81 3 3751 9799 E mail info rkcinst co jp ...