manualshive.com logo in svg
background image

 

2902351 (0)

 

Manuel d’entretien
Installation, use and maintenance instructions
Installatie-, gebruiks- en onderhoudsvoorschriften

Montage und Bedienungs Anleitung

 

 

Öl-Gebläsebrenner

Brûleur fioul

Oil burner

Stookoliebrander  

 

  

 

CODE

MODELL - MODELE - MODEL

TYP - TYPE

 

3746412

G10

464T1

D

F

GB

NL

Einstufig
Fonctionnement à 1 allure
One stage operation
Eentrapsbranders

Содержание RIELLO 40 G10

Страница 1: ...Installatie gebruiks en onderhoudsvoorschriften Montage und Bedienungs Anleitung l Gebl sebrenner Br leur fioul Oil burner Stookoliebrander CODE MODELL MODELE MODEL TYP TYPE 3746412 G10 464T1 D F GB...

Страница 2: ......

Страница 3: ...0 kg h Brennstoff Heiz l EL max Viskosit t bei 20 C 6 mm2 s 1 5 E Stromversorgung Einphase 230V 10 50Hz Motor Stromaufnahme 0 80A 2850 U min 298 rad s Kondensator 4 mF Z ndtransformator Sekund rspannu...

Страница 4: ...9 83 83 170 4 5 105 Es ist unbedingt n tig da zwischen Kessel t r und Flansch des Brenners die Isolierdich tung 9 Abb 1 dazwischengef gt wird Diese Dichtung hat sechs L cher welche eventuell wie auf n...

Страница 5: ...er beschriebene AUFF LLEN DER PUMPE Den Brenner starten und das Auff llen abwarten Sollte vor Eintritt des Brenn stoffes eine St rabschaltung erfolgen mindestens 20 Sekunden warten und danach den Vorg...

Страница 6: ...herung KLEMMLEISTE DES STEUERGER TS 530SE SERIENM SSIG AUSGEF HRT Kessel Stecker Brenner Steckdose 3 4 5 6 7 8 9 N L Gelb Gr n Blau Blau Braun Schwarz h Schwarz ACHTUNG NULLEITER NICHT MIT DER BEMERKU...

Страница 7: ...renners ausf hren und dabei das unten aufgezeigte Schema beachten ELEKTRISCHES VERDRAHTUNGSSCHEMA ACHTUNG NULLEITER NICHT MIT DER PHASE VERWECHSELN Braun Weiss 50V Blau Motor Kondensator Regelungtherm...

Страница 8: ...schaltung des Brenners durch Ein und Ausschalten der Thermostate berpr fen S7183 VERLAUF DES ELEKTRISCHEN KABELS 1 Kabeldurchf hrung 2 Kabelbefestigung 3 Klemmleiste N Nulleiter L Phase Brenner Erdung...

Страница 9: ...montiertem Bren nerrohr erledigt Sie ist von dem Durchsatz des Brenners ab h ngig und wird ausgef hrt indem man die Einstellspindel soweit dreht bis die Endebene des Brennerrohres mit der in der Tabel...

Страница 10: ...als um einen Rastepunkt ber dem in der Tabelle angegebenen Wert Ein Rastepunkt entspricht drei Umdrehungen der Spindel Markierung 3 am ussersten Ende der Spindel vereinfacht die Z hlung der Umdrehung...

Страница 11: ...tfernen die Luftklappe entsprechend einstellen die Haube erneut montieren und schliesslich den Russwert wieder kontrollieren ANMERKUNG Arbeitet der Brenner mit einem h heren Durchsatz als 9 kg h so mu...

Страница 12: ...k auf 14 bar einstellen 3 BRENNERKOPF EINSTELLUNG Den Kopf mit einer gr sseren Kerbe einstellen als in der Betriebsanleitung angegeben z B Nach Betriebsanleitung ist die Kopfeinstellung auf Rastepunkt...

Страница 13: ...1 5 E Alimentation lectrique Monophas e 230V 10 50Hz Moteur Courant absorb 0 80A 2850 t min 298 rad s Condensateur 4 mF Transformateur d allumage Enroulement secondaire 8 kV 16 mA Pompe Pression 7 15...

Страница 14: ...4 D5670 189 83 83 170 4 5 105 Il est indispensable qu entre la plaque frontale de la chaudi re et la bride du br leur soit interpos le joint isolant 9 fig 1 Ce joint isolant a six trous qui peuvent tr...

Страница 15: ...l d faut d tanch it de la vanne AMOR AGE POMPE Faire d marrer le br leur et attendre l amor age En cas de mise en s curit avant l arriv e du combustible attendre au moins 20 secondes apr s quoi r p te...

Страница 16: ...1 2 Marron Vanne T T D5334 Noir avec fusible BORNIER DE LA BOITE DE CONTROLE 530SE EXECUTEE EN USINE Fiche chaudi re Prise br leur 3 4 5 6 7 8 9 N L Jaune vert Bleu Bleu Marron Noir Compte heures h N...

Страница 17: ...SCHEMA DU BRANCHEMENT ELECTRIQUE ATTENTION NE PAS INVERSER LE NEUTRE AVEC LA PHASE Marron Blanc 50V Bleu Moteur Condensateur Thermostat de r glage Neutre 6A max N L M Noir N L 1 2 3 4 5 6 7 8 9 Bleu M...

Страница 18: ...en ouvrant les circuits des thermostats S7183 TRAJET DU CABLE ELECTRIQUE 1 Presse toupe 2 Blocage c bles 3 Bornier N Neutre L Phase Terre br leur Lampe s curit La cellule photor sistance est mon t e...

Страница 19: ...amme Indiqu e pour allumages basse temp rature REGLAGE TETE DE COMBUSTION Il est fait au moment du montage du gicleur avec gueulard d mont Il d pend du d bit du br leur et on l obtient en tournant la...

Страница 20: ...temp rature En tous cas le r glage de la t te de combustion ne doit pas s carter de plus d une encoche de la valeur indiqu e dans le tableau Chaque encoche correspond trois tours de la tige Un trou 3...

Страница 21: ...lever ce dernier agir sur le volet d air remonter le capot et alors recontr ler l indice de noircissement NOTA Si le br leur marche un d bit superieur 9 kg h enl ver le panneau mont l interieur du cap...

Страница 22: ...essous de 5 C augmenter la pression 14 bar 3 REGLAGE TETE DE COMBUSTION R gler la t te sur un rep re plus en avant de celui pr vu dans la notice technique Exemple dans la notice technique est pr vu de...

Страница 23: ...6 mm2 s 1 5 E Electrical supply Single phase 230V 10 50Hz Motor Run current 0 80A 2850 rpm 298 rad s Capacitor 4 mF Ignition transformer Secondary 8 kV 16 mA Pump Pressure 7 15 bar Absorbed electrica...

Страница 24: ...83 83 170 4 5 105 It is necessary that the insulating gasket 9 fig 1 is placed between the boiler door and the burner flange This insulating gasket has six holes which if necessary can be modified as...

Страница 25: ...PRIMING THE PUMP Start the burner and wait for the priming Should lock out occur prior to the arrival of the fuel await at least 20 seconds before repeating the operation A filter must be installed o...

Страница 26: ...S3 B4 1 2 Brown Valve T T D5334 Black TERMINAL BLOCK OF CONTROL BOX 530SE CARRIED OUT IN THE FACTORY Boiler plug Burner socket 3 4 5 6 7 8 9 N L Yellow Green Blue Blue Brown Black Hour counter h Black...

Страница 27: ...diagram below BURNER ELECTRICAL WIRING WARNING DO NOT EXCHANGE THE NEUTRAL WITH THE PHASE Brown White 50V Blue Motor Capacitor Regulating thermostat Neutral Switch with fuse 6A max N L M Black 230V 5...

Страница 28: ...t down of the burner by opening the thermostats RUN OF THE ELECTRICAL CABLE 1 Cable gland 2 Cable clamp 3 Terminal block N Neutral L Phase Burner earth Lock out lamp The photoresistance is fitted dire...

Страница 29: ...ntion it is therefore suitable for ignitions at low temperatures COMBUSTION HEAD SETTING This is done when fitting the nozzle with the blast tube removed It depends on the output of the burner and is...

Страница 30: ...at low temperatures In any case do not bring the combustion head setting more than one point away from that indicated in the schedule One set point corresponds to 3 turns of the rod a hole 3 at its en...

Страница 31: ...remove the cover by loosening the screw adjust the air damper remount the cover and finally recheck the smoke number NOTE When the burner works at a firing rate higher than 9 kg h remove the panel fit...

Страница 32: ...C increase the pressure to 14 bar 3 COMBUSTION HEAD SETTING Regulate the combustion head one set point further ahead than indicated in the instructions Example the instructions require to set the comb...

Страница 33: ...Stookolie max viscositeit bij 20 C 6 mm2 s 1 5 E Elektrische voeding Monofasig 230V 10 50Hz Motor Opgenomen stroom 0 80A 2850 t min 298 rad s Condensator 4 mF Ontstekingstransfo Secundair 8 kV 16 mA...

Страница 34: ...4 5 262 1 1 204 D5670 189 83 83 170 4 5 105 Het is absoluut noodzakelijk dat de flens dichting tussen de frontplaat en de flens wordt aangebracht 9 fig 1 De flensdichting heeft zes gaten die eventueel...

Страница 35: ...De brander in werking stellen en de aanzuiging afwachten Als de brander in veiligheid gaat voor er brandstof wordt toegevoerd moet men minstens 20 seconden wachten vooraleer de hele operatie te herha...

Страница 36: ...230V 0 1A max 1 N T1 T2 S3 B4 1 2 Bruin Klep T T D5334 Zwart met zekering KLEMMENBORD VAN DE CONTROLEDOOS 530SE UITGEVOERD IN DE FABRIEK stekker ketel 3 4 5 6 7 8 9 N L Geel groen Blauw Blauw Bruin Zw...

Страница 37: ...E AANSLUITINGEN OPGELET NULLEIDER EN FASE NIET OMWISSELEN Bruin Wit 50V Blauw Motor Condensator Regelthermostaat Nulleider 6A max N L M Zwart 230V 50Hz N L 1 2 3 4 5 6 7 8 9 Blauw Bruin Klep T T D5228...

Страница 38: ...stilstand van de brander nagaan door de thermostaten te openen TRAJECT VAN DE LEIDINGEN 1 Wartel 2 Vasthechting kabels 3 Klemmenbord N Nulleider L Fase Aarding brander Veiligheidslampje De fotoweerst...

Страница 39: ...r Geeft een betere vlamhaking Aanbevolen voor ontsteking bij lage temperatuur REGELING VAN DE VERBRANDINGSKOP Dat gebeurt wanneer men de sproeier plaatst met gedemonteerd kanon De regeling is af hanke...

Страница 40: ...arde die op de tabel is aangeduid Elke inkeping stemt overeen met drie toeren van de stang Een opening 3 op het uiteinde vereenvoudigt het tellen van de toeren REGELING VAN DE LUCHTKLEP De beweegbare...

Страница 41: ...de lucht klep regelen opnieuw de kap monteren en de Bacharach opnieuw controleren OPGELET Als de brander een debiet van 9 kg h overschrijdt dan moet men het paneel aan de binnenkant van de kap wegneme...

Страница 42: ...stookolie daalt onder 5 C dan moet men de druk verhogen tot 14 bar 3 REGELING VAN DE VERBRANDINGSKOP Regel de kop op een hogere waarde dan de waarde die voorzien is in het instructieboekje Voorbeeld v...

Страница 43: ......

Страница 44: ......