RE928X Flexible Bus CDMA Communicator 

 

Features 

 

 

Connects panels to GSM Network 

 

Compatible with: 

o

 

Honeywell Vista® 15P and 20P 

 

o

 

DSC PowerSeries

 

o

 

UTC NX [Future: Concord]

 

 

Enables: 

o

 

Alarm Reporting 

o

 

Interactive Control Functions 

o

 

Ethernet data reliability 

o

 

Z-Wave Communicator included 

 

Key Instructions

 

 

The same unit works for Vista, Power Series, & UTC NX.   

 

Selectable switch determines panel compatibility. 

 

DO NOT MOUNT INSIDE METAL CAN – there are radios on the boards that 
need to be in free-air to communicate. 

 

Communicator must be connected to a 12V power supply with battery 
backup, such as the control panel's aux power output. 

 

The communicator should be mounted in a location that will optimize 
cellular signal strength. Mount as high in the building as possible.  

 

RE927X communicates with the Vista 15P/20P via AUI device 2. Enable 
AUI 2 in the Vista. 

 

The RE928X may be used as a backup for the RE920X or RE926X 
communicators. Refer to “Using RE928X as a Backup”.

 

Wiring Instructions  
NOTE:  

Some programming must be done PRIOR to connection  

Maximum cable lengths shown in the table below, this assumes the 
communicator is the only device attached to the cable. If multiple devices 
share the same cable, the maximum cable length must be derated accordingly.

 

 

Wire Size (AWG) 

Maximum cable length to Control Panel 

18 

350 

22 

130 

24 

75 

 
 
 
 
 
 
 
 
 
 

RE928X_Flexible Bus CDMA Communicator

 Page 

2

 of 

10

 

4-Feb-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SIM Card

DSC 

PowerSeries

YEL

GRN

AUX - BLK

AUX + RED

Green

Yellow

Red

Black

RE927X

A/Rx

CLK
B/Tx

DATA
GND
+12V

 

Honeywell

Vista 20P or 15P

DATA OUT

7

DATA IN

6

AUX +

5

AUX -

4

Green

Yellow

Red

Black

RE927X

SIM Card

A/Rx

CLK
B/Tx

DATA
GND
+12V

RE928X 

RE928X 

RE928X 

Summary of Contents for RE928X

Page 1: ...optimize cellular signal strength Mount as high in the building as possible RE927X communicates with the Vista 15P 20P via AUI device 2 Enable AUI 2 in the Vista The RE928X may be used as a backup for the RE920X or RE926X communicators Refer to Using RE928X as a Backup Wiring Instructions NOTE Some programming must be done PRIOR to connection Maximum cable lengths shown in the table below this ass...

Page 2: ...ady to Arm 9 Installation is complete RE928X_Flexible Bus CDMA Communicator Page 4 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com DSC Power Series Programming Compatible DSC Panels PC580 Power 432 PC5020 Power 864 PC1555 Power 632 PC1616 PC1555MX Power 632 PC1832 PC5010 Power 832 PC1864 PC5015 Power 832 1 Refer to server setup instructions and set up the account on the...

Page 3: ... keypad devices they support Be sure that the panel you are connecting the communicator to does not have more than the number of support devices connected 2 User codes that are added to the system or edited thru the communicator will have the default or previous partitions enabled If you desire the users to have different partitions enabled you will need to modify the partitions thru the NX keypad...

Page 4: ...Dealer Portal User Guide for details Power LED The rate the Power LED flashes indicates current operating mode Flashing every 1 second Primary Mode Flashing every 3 seconds Backup Mode RE928X_Flexible Bus CDMA Communicator Page 8 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com LEDs Bus Board LEDs Indication Green On when the board is powered and running Red May flicker ...

Page 5: ...vice and persons during operation To ensure compliance operation at closer than this distance is not recommended The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter RE928X_Flexible Bus CDMA CommunicatorPage 10 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com IC Notice This device complies with I...