manualshive.com logo in svg
background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

    

ESCAPE OF GAS

    Should a gas leak be suspected, contact your gas 
    supplier  without    delay.
    Do NOT search for gas leaks with a naked fl ame.

    

WARNING: 

This appliance must be earthed.  Do not touch

      or tamper with this sealed unit or its components.

1.

INTRODUCTION

     

1.1       Please carefully read information given in the booklet to 

help you again maximum control from your appliance 
with   minimum  trouble and cost.

     1.1.1

    

Your Ravenheat Condensing Low Nox Combination 

Boiler  has  been  designed to supply your Central 
Heating and   Domestic Hot  Water directly from one 
unit. When Central Heating is operating, the circulation 
will be  interrupted when Domestic Hot Water is being 
drawn off.
This will normally not affect the level of Heating.

PLEASE NOTE

Due to the high effi ciency and resulting low fl ue gas 
exhaust temperature a white plume of condensation 
vapour (cool steam) will be emitted from the fl ue outlet 
terminal, this is quite normal. It will be particularly evident 
during periods of low outdoor temparatureor when the 
boiler is working at its optimum performance
(Plume Management kit is available on request)

1.2 

    

CLEARANCES AROUND THE BOILER

 

Above 125 mm   ( 5  inches)

Below  150 mm   ( 6  inches)
Front    450 mm  (18  inches)
Sides        5 mm  (0.2 inches)
25mm (1inch) in front when installed in a cupboard 

 

1.2.1   Minimum clearences are required for safety and 

maintenance. Do NOT obstruct any purpose made 
ventilation opening if boiler has been fi tted in a 
compartment.
Never hang clothes,ect, over the appliance

     

1.3

      

USER CONTROLS (Fig.1) 

     

1.3.1  

 

This appliance is designed to operate with the 

minimum of attention by the User. All the controls 
are to be found on the control pannel.

     

1.4       OPERATING SAFETY CHECKS TO PROTECT 

YOUR APPLIANCE

     

1.4.1   Before lighting the Appliance check Central Heating  

system pressure (Fig.1 item 7) is not less than 1 
bar. If it is below this do not light but consult your 
installer about refi lling your system as you may 
have  a leak in the system.

     1.4.2   In the event of malfunction of the appliance will be 

indicate by the relevant error code (Table1) on 
Digital Display of the control panel (Fig.50).
These can be Reset by press a RESET  button .

If lockout code persist leave the appliance shut 
down and consult your installer/service 
engineer immediately.

   

 Table 1

  USER’S GUIDE

CSI 120(T) Low Nox  

 (with or without built in timer)

CONDENSING LOW NOX SYSTEM INNOVATION SUPER HIGH EFFICIENTY  AUTOMATIC

    MODULATING COMBINATION BOILER FOR CENTRAL   HEATING AND DOMESTIC HOT WATER

It is the law that all gas appliances are installed by 
a competent person, in accordance with the gas 
safety installation and use current regulations.To 
the current Gas Safety (Installation and Use) 
Regulations B.S.5440:2-(2000).

 All CORGI registered installers carry a CORGI ID card and 
have a registration number. Both should be recorded in your 
boiler Log book. You can check your installer by calling 
CORGI direct on 01256 732300

.

01:  Lock out from the Flame Control Unit

 02:  Flue System obstruction

04:  Overheat Lockout

 06: Open or short circuit on Sanitary probe
 12: Open or short circuit on Heating probe
 14: Flame simulation on Flame Control Unit 
 17: Fault on Fan Control
 28: Water Flow Switch Fault or low  pressure  
        in the heating system

  

1

Отзывы: