TROUBLE

CAUSE

REMEDY

※ 

Consult your gas stove supplier or qualified technical personnel if you may not solve 

    problem.Be sure to turn off the main cock.

After the ignition knob is
released, the flames are
extinguished.

Although there are ignitions,
the burners do not light on.

Abnormal sounds during
combustion.

Smell of gas.

The ignition knob is not turned
on properly.

Air is entrapped in the rubber
gas hose.

The ignition spark device is
dirty  or wet.
The rubber hose is bent.

Short of gas supply

The burner caps are not
mounted properly.

Gas leakage from cracks of
rubber hose.
Loose connection of rubber hose.

Turn it counter clockwise.

Open the main valve.
Repeat turning it on 
several times.

Replace gas vase.

Mount them in place.

Replace it.
Secure the rubber hose
with the hose clamp.

The power is disconnected.

Connect the power.

Clean or dry up.

Install it properly or replace it

7