SLIM 57 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
TM
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
FIXTURE MOUNTING
To ensure weatherproof seal, apply weatherproof silicone
sealant around the edge of the
Housing
and/or
Junction
Box
. This is especially important with an uneven wall
surface. Silicone all plugs and unused conduit entries.
1. Loosen
Door Screws
and open the
Door
. Screws will
remain in place.
2.
Tether Cable
provided for hands free wiring.
3. Knock out appropriate
Slots
when mounting to junction
box (not supplied) or lag bolt to mounting surface using
locations noted below. Use
Leveling Bubble
to level
fixture.
4. Feed supply wires through
Junction Box(not supplied).
Check that the
Gasket
is fully sealed.
5. Make sure
Housing Gasket
is properly seated. Close and
tighten the
Door Screws
. Silicone all
Plugs
and unused
conduit entries.
6. If outdoor surface is irregular, use caulk to seal any gaps
around the
Housing
.
Housing
Gasket
Junction Box
(not supplied)
Door
Knock Out Slots
Door Screws (2)
Plug
Leveling Bubble
Gasket
Lag Bolt
Locations
Drilling
Template
Housing
13 1/4”
9 5/8”
4 13/16”
5 5/8”
8 5/16”
WIRING
Universal voltage driver permits operation at 120V thru
277V, 50 or 60 Hz, except fixtures factory ordered with a
120V photocell (/PC) and 277V photocell (/PC2) and fixtures
factory ordered with a 120V swivel photocell (/PCS) or 277V
swivel photocell (/PCS2) or 480V swivel photocell (/PCS4).
Units ordered with (/480V) suffix are 480V.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply
ground.
Tether Cable