background image

FFLED    120W INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding 

is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A 

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

SLIPFITTER MOUNTING

1. 

The slipfitter mounting fits a 2 3/8” O.D. 

Tenon

. Place the 

slipfitter over the 

Tenon

 and secure the fixture with the 

Set Screws

 on the side of the 

Slipfitter

.

2. 

To adjust the angle of the 

Slipfitter

, remove screws and 

plug on 

Round Cover Plate

. Remove the 

Round Cover 

Plate

. Loosen the 

Locking Bolt

 and adjust the angle of 

the fixture as desired.

3. 

Feed supply wires from 

Tenon

 to

 Slipfitter 

and make 

necessary connections in the 

Slipfitter

 and knot wires for 

strain relief.

4. 

Tighten the 

Locking Bolt

 and re-attach 

Round Cover 

Plate

. Seal plug on side of 

Round Cover plate 

with 

Teflon Tape or silicone sealant.

TRUNNION MOUNTING

CAUTION

UL and C-UL listed or CSA certified liquid tight 

cord grip suitable for use with STW flexible cord shall be 

used for connection to a wet location outlet box provided 

by others.

To adjust the angle of the fixture using the trunnion:

1. 

Loosen the 

Pivot Bolts

 & angle locking screw.

2. 

Adjust fixture to desired angle.

3. 

Tighten 

Pivot Bolts

 & angle locking screw.

Locking 

Bolt

Round Cover Plate

Pivot Bolts

FFLED Trunnion

FFLED Slipfitter

Set Screws

Tenon

Slipfitter

WARNING: RISK OF SERIOUS INJURY OR DEATH!

DO NOT MOUNT THE SLIPFITTER TO A TENON OR BRACKET THAT IS MORE THAN 20 DEGREES FROM VERTICAL. MOUNTING 

AT ANY ANGLE OTHER THAN 0-20 DEGREES INCREASES THE RISK OF DISENGAGEMENT AND/OR FAILURE OF THE 

SLIPFITTER. INSTALL THE POLE ON A SECURE BASE OR INSTALL THE BRACKET TO A WALL FIRST. THEN PLACE LUMINAIRE 

ONTO THE POLE OR BRACKET. DO NOT LIFT LUMINAIRE ASSEMBLED TO POLE OR BRACKET. LUMINAIRE MAY DISENGAGE.

Reviews: