background image

TELINK-SNMP2

User Manual

Volume 1

 

Manufactured by 

 Italy 

Summary of Contents for TELINK-SNMP2

Page 1: ...TELINK SNMP2 User Manual Volume 1 Manufactured by Italy...

Page 2: ...ed memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the co...

Page 3: ...eneral Description 3 5 Installation and configuration procedure 4 5 1 Preparation 4 5 2 First Power On and Set Up 6 5 3 Management Software 7 5 4 SNMP Telemetry 22 6 External Description 25 6 1 Front...

Page 4: ...TELINK SNMP2 ii User Manual Rev 1 1 07 02 14 This page was intentionally left blank...

Page 5: ...e measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commitment...

Page 6: ...bsent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers the r...

Page 7: ...ected through male and female connectors or through flat cables terminated by connectors This design facilitates maintenance and module replacement It also include a Web Server and SNMP agent that all...

Page 8: ...ardware and firmware features and capabilities Please see the relevant sections for additional details IMPORTANT when configuring and testing the transmitter in which this telemetry unit is integrated...

Page 9: ...TELINK SNMP2 interface through the telemetry signal cable Figure 5 1 2 Connect the ETHERNET output of TELINK SNMP2 interface to the appropriate input of your ADSL router or LAN network If the connect...

Page 10: ...N IP address was previously modified it is necessary to use the new one At this point the following page opens By factory the RVR uses the following adjustments IP address 192 168 0 244 Netmask addres...

Page 11: ...shows possible viewing options This picture shows the Main menu after access Menu 1 To enter in one of the sub menus select the name and then click on item to enter To go back to MAIN menu just click...

Page 12: ...WEB firmware Web Software Date Shows the issue date of WEB firmware Device Date Shows the day stored on the equipment dd MM yyyy Device Time Shows the time stored on the equipment hh mm Local Date Sho...

Page 13: ...urrent page Ready With Auto refresh disabled the measures are frozen Stopped at the time when you uncheck the box and gave available in a legible form by the current page This page shows the user the...

Page 14: ...ve SWR Power Good Shows the status of power good Foldback Shows the triggered status of the foldback function automatic reduction of output power Ext R F Mute Shows the status of power inhibition by a...

Page 15: ...display all alarms saved by the system any new event will automatically delete the older ones This page shows the user the alarms of the exciter connected to the TELINK SNMP2 interface Menu 4 Value S...

Page 16: ...ELINK SNMP2 interface via WUI Please note that the User Name user can not be changed Menu 5 Value Shows and set the password for maintenance user enables read only parameter The Erase button allows yo...

Page 17: ...ce by pressing the NTP Sync button Local Date Time Allows you to align the date and time stored in the equipment with local Date by pressing the Loc Sync button New Location Name Setting of the statio...

Page 18: ...or disable the Auto refresh by clicking on the relevant box With Auto refresh enabled the measures are taken every 3 seconds Get Data and gave available in a legible form by the current page Ready Wit...

Page 19: ...t item at bottom right of the menu you can delete all pending alarms Note The complete list of alarms not limited to the 20 viewable through TELINK SNMP2 is available by downloading the log file This...

Page 20: ...tor of TELINK SNMP2 interface via WUI Please note that the User Name user and Admin name admin can not be changed Menu 9 Value Shows and set the password for maintenance and administrator user enables...

Page 21: ...etting various parameters Press the Change Settings button then Apply Settings button to confirm selection and be redirected to modified IP Menu 10 Menu 11 Note to make changes within these sub menus...

Page 22: ...change the DNS record without changing client settings DNS2 server Shows the second DNS server address Domain Name System in case the server should change the server hosting a service or it is necessa...

Page 23: ...ty Shows the set string for Read command that allows you to monitor the different variables of the system managed Write Community Shows the set string for Write command that allows you to monitor the...

Page 24: ...g for Trap command New Trap type Set the new Trap type 0 for Trap or 1 for Inform This set is valid for all trap New Inform Trap type Setting of inform trap retry number Write the number of retry from...

Page 25: ...ton to confirm the upgrade press the Cancel button the parameter setting will remain as previously set Menu 13 Browse Allows to types the full pathname directly into the input box or you can search th...

Page 26: ...B you can power on or off the transmitter view the state of some parameters like TransmitterOPMode this is the only state able to write RFPresent Fault state that in the TEX correspond to Unlock state...

Page 27: ...apply change to update the IP information of the Ethernet interface 2 OID rvr trtap process restart to update the trap information changed 3 OID rvr agent restart to update the community information...

Page 28: ...24 34 User Manual Rev 1 1 07 02 14 TELINK SNMP2 Menu 17 MIB2 System tree Menu 18 Trap receiving Menu 19 Received trap details System Name and Location...

Page 29: ...scribes the components found on the front and rear panel of TELINK SNMP2 6 1 Front Panel Figure 6 1 1 LOCAL Yellow LED Lit on when the equipment is in local mode 2 REMOTE Switch to select the local or...

Page 30: ...B9 male connector for I2C bus 6 RS232 485 Not used 7 RS232 DB9 connector for direct serial communications in RS232 standard for maintenance 8 Service DB9 connector for direct serial communications in...

Page 31: ...ription 6 3 1 I2C Connectors Type DB9 Male Female 1 GND 2 SDA 3 SCL 4 N C 5 GND 6 N C 7 N C 8 N C 9 N C 6 3 2 RS232 Type DB9 Male 1 N C 2 RxD 3 TxD 4 N C 5 GND 6 N C 7 N C 8 N C 9 N C 6 3 3 SERVICE Ty...

Page 32: ...28 34 User Manual Rev 1 1 07 02 14 TELINK SNMP2 6 3 3 ETHERNET Type RJ45 female 1 TX 2 TX 3 RX 4 N C 5 N C 6 RX 7 N C 8 N C...

Page 33: ...Phisical Dimensions W x H x D 483 x 44 x 238 mm Weight 4 kg Environmental working temperature 10 to 50 C Cooling type Convection cooling Analog Digital Analog Relay RS232 Yes RS485 Yes IIC BUS Yes RJ...

Page 34: ...S232 Green Led Blinks during data transmission in SERVICE connector TX RS485 Green Led Blinks during data transmission in RS485 standard on connector internally connected with Main card SYNOPTIC 2 Gre...

Page 35: ...s made up of various modules linked to each other through connectors so as to make maintenance and any required module replacement easier 9 1 Upper View The figure below shows the equipment upper view...

Page 36: ...estoring IP Address Following the procedures described here below allows you to force an hardware reset on TELINK SNMP2 to restore IP address to factory settings 1 Remove mains supply and the equipmen...

Page 37: ...led attention and snmp alternate blinking Figure 10 3 4 Put OFF the switch number 7 and restart the equipment 5 Connect to equipment at default address 192 168 0 244 in WEB mode and in the page Netwo...

Page 38: ...34 34 User Manual Rev 1 1 07 02 14 TELINK SNMP2 This page was intentionally left blank...