background image

AUTOMATION FOR SLIDING DOORS

use and m

ainte

nan

ce 

m

an

ua

l

WINNY LIGHT

E

N

G

L

I

S

H

V03/2016

           NEW MODEL

Summary of Contents for WINNY LIGHT

Page 1: ...AUTOMATION FOR SLIDING DOORS use and mainte n a n c e m a n u a l WINNY LIGHT E N G L I S H V03 2016 NEW MODEL ...

Page 2: ...rtical manual adjustment and nylon wheels lubrications not required Ÿ Control panel supply 24 Vac 6 A with microprocessor Ÿ Digital programming of operating parameters with permanent memory Ÿ Motor speed control with PWM signal Ÿ Optical encoder input with wiring test Ÿ Maneuvers and alarms will be indicate in a 7 segments display and by acoustic warning signals Ÿ Operations counter and maintenanc...

Page 3: ... lock with manual release 4 Belt Tensioner 5 Back up battery 6 Control unit 7 Photocells amplifier 8 Motor support with pinion 9 Motor optical encoder 10 Transformer 11 Input Power supply terminal 12 Mechanical limit switch 13 Pulling cart 14 Free cart 160 mm 107 mm 138 mm 75 mm 45 mm 15 25 mm ANTIPANIC SYSTEM ...

Page 4: ...sage or the end of the profile should coincide wit the end of the opening passage COVERALL FASTENING Remove the cover Drill holes on the front side of the coverall it is recommended not to exceed a distance of 600 mm between the holes WARNING Protect the electronic equipment before you drill the holes and then wipe away any aluminum residues from the belt and the guide Calculate the measurements f...

Page 5: ...e screw B make the adjustments screwing the leaf goes up unscrewing the leaf goes down At the end of the operation block the nuts A Leaf Nut A Nut Screw B LEAVES HOOKING Place the leaf under the carriages of the coverall and fast with 8 10 mm screws not supplied to a distance from the ends of the leaf of 100 150 mm 100 150mm 100 150mm ...

Page 6: ...rew D CONFIGURATION RIGHT LEFT All our coveralls are assembled in such a way that the procedures for inversion are minimum without changes of space between components or belt length 2 LEAVES the pulling trolleys will not have obstacles in the stroke they will run under the equipment using the full length of the coverall 1 LEAF to switch from the left to the right you just need to reverse the belt ...

Page 7: ...or Ÿ Loosen the screws A and adjust to the desired stroke Ÿ Tighten the two screws Screws A COVER REMOVAL To remove the front cover unscrew the two screws B at the ends of the box and lift To lift the front cover unscrew the two screws B at the ends of the box and rotate Screw Screw B ...

Page 8: ...hat came with their anchoring systems WARNING Adjust the force according to the diameter of the cable With the box open you will notice the steel cable that comes out on the on the left side of the pulling pulley Drill a hole of 2 5mm perpendicular to the cable Fix the bracket onto the wall to keep the electro lock pulled permanently Bracket Bracket Clamp Clamp Plate Plate To unlock manually pull ...

Page 9: ... aluminum support Screws Insert the glass wing thickness 10mm Block the support with the screws and wait at least 48 hours for drying Glass wing Support Silicone Support 10mm 10mm SUPPORT FOR 10mm thick GLASS WINGS Optional ...

Page 10: ...d use the UP and DOWN keys to set the desired value The settings will be saved automatically a few seconds after no further keys are pressed or can be saved immediately by pressing the INVIO button until the last parameter is reached and then one further time to confirm the values The new settings are confirmed with the message rd on the display and a 1 second tone Figure 1 contains a list of all ...

Page 11: ...l 13 0 30 sec Delay for automatic closing 14 0 30 sec Delay for auxiliary closing 15 0 30 sec Delay for partial closing 16 1 10 decimi sec Time for electric lock 17 0 15 number System configuration menu 1 18 0 15 number System configuration menu 2 19 0 1 number System configuration menu 3 20 0 9 number 1st digit PIN code A 21 0 9 number 2nd digit PIN code B 22 0 9 number 3rd digit PIN code C 23 0 ...

Page 12: ...osed x x x x x x x x security inputs into logic normally open x x x x x x x x FUNCTION 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 audible alarmenabled x x x x x x x x audible alarmdisabled x x x x x x x x set alert for 1 500 000 mechanical cycles x x x x x x x x set alert for 300 000 mechanical cycles x x x x x x x x mechanical cycles meter enabled x x x x x x x x mechanical cycles meter disabled x x x...

Page 13: ...proach speed 10 Approach distance when closing distance from closed door stop when the door is slowed to reach the programmed approach speed 11 Partial opening percentage in reference to closed door used to open door when partial opening is selected 12 Manual travel 0 door is actively held shut 1 door opens freely 2 automatic opening when door is manually pulled from closed position 13 Delay for a...

Page 14: ...eplaced BATTERY TEST Indicates when the battery test is being carried out HIGH LINE Voltage of AC power supply 230 V too high LOW LINE Voltage of AC power supply 230V too low TEST PINCODE PIN code being checked PINCODE ERROR Incorrect PIN code entered SAFETY ERROR Safety nc open or not installed correctly ENGINE X ERROR IMPEDIMENT Mechanical impediment to the start of the reset phase The c8 will b...

Page 15: ...hen the last digit has been confirmed the screen will display tP to indicate that the PIN code is being checked if the code is correct the attention tone will sound two short tones and the screen will show the first user programmable parameter If the PIN code was entered incorrectly the message EP will be displayed and a tone will sound for approximately 1 second then the control unit will automat...

Page 16: ...at corresponds to the low part of the figure is displayed After a few seconds the screen returns to displaying the flashing line The two numbers are combined as in the following illustration Therefore this unit has completed 437 000 cycles 04 C 37 C INVIO INVIO 04 37 000 HIGH PART LOW PART MULTIPLY X 1000 If the buzzer option is enabled upon reaching the maximum number of cycles the system will in...

Page 17: ... C N C N C N C N C RED Photocell Photocells Amplifier SHIELD ENCODER FROM ABOVE 4 POLE AMP CONECTOR INSIDE OF DIGITAL SELECTOR 0 22 WIRE 7Cm NEOPRENE INSULATION ON KEY 1 24V SELECTOR 2 CLOSED 3 ENTRY 4 OUTPUT 5 APEN 6 PARTIAL 7 RESET 8 0V SELECTOR 9 10 CONTACT FOR PARTIAL OPENING IN CLOSE KEY PULSE 11 12 AUXILIARY NOT AVAILABLE 24V CLOSED IMPUT OUTPUT OPEN PARTIAL RESET 0 V SELECTOR A BROWN B WHIT...

Page 18: ...erential switch suitable for the product and conforming to current standards The manufacturer declines any and all responsibility for product integrity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintenance and ...

Page 19: ...ations Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC and their amendments and modifications and with the regulations set forth by the National Legislative Body of the country in which the machinery is destined for use Via Seccalegno 19 36040 Sossano VI Italia Managing Director Luca Borinato Sossano 1 1 2016 WINNY LIGHT AUTOMATIC...

Page 20: ...QUIKO ITALY Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...

Reviews: