Flush On/Off Thermostat 2 

 

 

 

 

Quickstart 

This is a 

secure HVAC-Thermostat 

for 

Europe

. To run this device please connect it to your mains power 

supply. To add this device to your network execute the following action: 
 

SmartStart Inclusion

 

1. Scan QR code on device label and add S2 DSK to Provisioning List in Gateway (hub) 
2. Connect the device to the power supply (with the temperature sensor already connected). 
3. Inclusion will be initiated automatically within few seconds of connection to the power supply and the device will 
automatically enroll in your network (when the device is excluded and connected to the power supply it 
automatically enters the LEARN MODE state). 
 

Classic Inclusion

 

 
1. Enable add/remove mode on your Z-Wave gateway (hub) 
2. Connect the device to the power supply (with the temperature sensor already connected*) 
3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds (The device has to get On/Off signal 3 
times, meaning 3 times click on the push button or with the normal button 3 times On/Off.) (this procedure puts 
the device in LEARN MODE) in the first minute after power cycle. 
OR 
If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 3 and 6 seconds 
(this procedure puts the device in LEARN MODE) 
4. A new device will appear on your dashboard 
5. Inclusion with the switch connected to I1 terminal is not limited by time 
*If connecting the temperature sensor, switch off the power supply. 

Important safety information 

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or 
may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage 

Summary of Contents for FLUSH ON/OFF THERMOSTAT 2

Page 1: ...the device to the power supply with the temperature sensor already connected 3 Toggle the switch connected to the I1 terminal 3 times within 3 seconds The device has to get On Off signal 3 times meani...

Page 2: ...tically turn the device on if the temperature is too low antifreeze Automatically turn the device on off based on Hysteresis Works on 110 240 VAC or 24 30 VDC Prepare for Installation Reset Please rea...

Page 3: ...esent in the wiring Take extra precautions to avoid accidentally turning the device on during installation Step 2 Installing the device Connect the device exactly according to the diagrams shown below...

Page 4: ...o communicate with the devices of this network This process is called Inclusion Devices can also be removed from a network This process is called Exclusion Both processes are initiated by the primary...

Page 5: ...eeping battery devices without a central controller 5 Dont poll FLIRS devices 6 Make sure to have enough mains powered device to benefit from the meshing Association one device controls an other devic...

Page 6: ...the previous Wattage reading starting at 1 the lowest value possible Parameter 42 Watt Power Consumption Reporting Time Threshold for Q Set value refers to the time interval with which power consumpt...

Page 7: ...OTE1 Antifreeze is activated only in heating mode and it uses hysteresis of 0 5C NOTE2 If configuration parameter 78 Scale selection is set to Celsius then valid interval is 125125 12 5 C12 5 C resolu...

Page 8: ...to Fahrenheit note that Fahrenheit values will be converted to Celsius degrees Due to conversion algorithm please be advised that configuration value could drift when converting values back and forth...

Page 9: ...ion parameters sets reporting threshold between reported temperature and actual temperature for reporting temperature at association group 4 NOTE1 If configuration parameter 78 Scale selection is set...

Page 10: ...turer Specific V2 Meter V4 Notification V8 Powerlevel Security Security 2 Sensor Multilevel V7 Supervision Thermostat Mode V3 Thermostat Operating State Thermostat Setpoint V3 Transport Service V2 Ver...

Page 11: ...work Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to...

Reviews: