background image

PYSER-SGI LIMITED

PNP-MC Pocket Scope

Operator’s Manual

560 - 007 - 51

100/03/09

NSN: 5855-99-855-1401

YSER-SGI LIMITED

Fircroft Way, Edenbridge, Kent United Kingdom, TN8 6HA

Telephone: +44 (0) 1732 864111

Facsimile: +44 (0) 1732 865544

Email: [email protected]

www.pyser-sgi.com

Summary of Contents for PNP-MC

Page 1: ...Scope Operator s Manual 560 007 51 100 03 09 NSN 5855 99 855 1401 YSER SGI LIMITED Fircroft Way Edenbridge Kent United Kingdom TN8 6HA Telephone 44 0 1732 864111 Facsimile 44 0 1732 865544 Email sales...

Page 2: ...al 21 Chapter 5 Accessorie Mounting 5 3 PNP MC with head mount helmet mount fitting guide 1 Attach monocular to the mount with thumbscrew A 2 Depress plunger B to lift monocular into the vertical posi...

Page 3: ...ard 15 HeadHarness 16 Helmet Mount 16 Bridge Kit 16 Weapon Mount 17 Anti Mist 18 150mw Illuminator IR LED 18 Lanyard 18 Camcorder Camera Adaptor 18 Optical Module 18 Camera lens to C mount Adaptor 19...

Page 4: ...adaptors enable the PNP MC to be mounted onto a wide variety of SLR and video cameras including CCTV cameras Thus standard photographic equipment can be quickly turned into powerful effective night t...

Page 5: ...commercial AA battery Weight includes eyecup and lens cap Tripod mount Standard UNC thread Construction Moulded glass filled polymer Eyeguard Contoured soft fold back rubber eyecup Environmental Water...

Page 6: ...to the adaptor 3 Adjust the fore aft position of the PNP MC on the adaptor for optimum eye relief by unscrewing the two Allen bolts E and moving the upper part of the adaptor into the best position fo...

Page 7: ...erfacing the PNP MC to 35mm SLR and video cameras including CCTV cameras using special purpose adaptors fitted to the same threading 1 4 PNP MC Main parts Fig No 2 PNP MC Parts description 1 Pocket sc...

Page 8: ...Light Protection The image intensifier tube is protected against bright lights by a Bright Light Sensor The PNP MC can be switched on with caution and only for a few seconds in indoor artificial light...

Page 9: ...d a Clean lens with lens image objective lens cleaning tissue quality If lens is internally fogged send unit to repair maintenance facility b Eyepiece out of Adjust diopter ring focus to bring picture...

Page 10: ...h 2 4 PNP MC Operation with DSLR SLR cameras interchangeable lenses 2 4 1 Installation 1 Use any DSLR SLR camera with it s lens set to 35 50mm focal length 2 Load a high sensitivity film B W 400 1600...

Page 11: ...the sharpest image is obtained through the DSLR SLR eyepiece 6 Adjust the shutter speed according to the DSLR SLR lightmeter 2 6 PNP MC Operation with CCTV cameras 2 6 1 Installation 1 Mount the CCTV...

Page 12: ...camcorder VIDEO CAMCORDER VIDEO CAMERA RING ADAPTOR PNP MC POCKET SCOPE 1 Remove original lens from camera 5 and set it to Manual 2 Fit appropriate optical module 4 directly to camera then after fold...

Reviews: