SWITCH   

FEATURE                           POSITION 

MEANING 

          

ON

LED Enable

A

LED Enable

OFF

LED Disable

ON

Periodic self test

B

Self Test mode

OFF Remote self test

C

Relay mode

ON

          Relay normally closed

OFF          Relay normally open

D

Digital signal

ON

SPP+

Processing

OFF

SPP+1

                                                   

OFF

PC 1

ON

PC 2

E

Digital signal

ON

SPP+

Processing

ON

SPP+1

                                                   

OFF

PC 1

OFF

PC 2

F

Walk test mode

ON       Walk test LEDs disable
OFF      Walk test LEDs enable

INSTALLATION

1

. Remove case lid by unscrewing fixings screw as illustrated in 

    and unclip the PCB, taking care not to touch the Pyro sensor

    labeled         .

2

. Choose wall fixing holes, labeled         and        on diagram.

3

. Mark wall for fixing positions (Do not route wires near mains cabling,

    avoid vibrating surfaces and mount only on a solid wall). 

4

. Drill fixing holes. 

5

. Fix case to wall.

6

. Replace PCB again taking care not to touch the pyro sensor (labeled

            on diagram).

7

. Select and fit the appropriate lens for your application (See diagram        ).

8.

 Using dip switches (See diagram        ) select required features and modes of 

    operation.

9.

 Carry out walk test.

10.

 Re fit detector front cover using fixing provided (See diagram        ).

POTENTIAL FALSE ALARM HAZARDS.

               

1

. Direct sunlight on detector may cause false alarms.

2

. Pets and animals may cause false alarms.

3

. Mounting detector near heaters may cause false alarms.

4

. Draughts from open windows may cause false alarms.

DIAGRAMS

     

Coverage Patterns

     Dimensions and weight

     Board layout

     Pyro sensor

     DIP Switches

 

     Mounting and cable entry knockouts

     Cable entry knockouts

     Wall fixing knockouts

     Wall fixing knockouts

 

     Detection methods

 

     Detailed connections

     Control panel connections

     Tamper operation

     Alarm relay operation (N/C)

     Alarm relay operation (N/O)

     Removal and replacement of front cover and lenses

     Front cover fixing screw

     Removing and replacing the lens

     Optional rear tamper.

GB

C1

C

G2

G1

C2

G1

C1

D2

D3

B

A

G

C

C1

C2

C3

D1

D

D2

D3

E

F

F1

F2

F3

F4

G1

G2

H1                 H2                H3

Power up             Normal alarm      Normal alarm
                                                        walk test selected 

H4   Latch

Center LED flashes at intervals of 1-2 seconds 

H5   Fail self test

Center and outside LEDs flash alternately 

WARRANTY

This product is sold subject to our  standard warranty  conditions and is  warranted against 
defects in workmanship for a period  of five years. In the interest of continuing  improvement 
of quality, customer care  and design, Pyronix Ltd  reserve the  right to amend specifications 
without giving prior notice 

DIP switches (see diagram      )

Note:  As Factory Default all switches are ON

1

1

1A

1A

1B

1B

1C

1C

2

2

3

3

3A

3A

3B

3B

4

4

5

5

6

6

7

7

OPERATION OF FEATURES

1. LED Enable / Disable  (Switch A) 

ON   =   LED Enable
OFF =   LED Disable

2. Self Test (Switch B)  

ON   =   Periodic self test mode
OFF =   Remote self test mode

  

2.1 Periodic Test

  

In periodic test mode, a self test is commenced after 5 hours of PIR 

  inactivity. If the test passes there is a short delay before the detector 
  settles and resumes to normal operation.

  

2.2 Remote Test

  

The remote test will only be activated if the RT terminal is connected to 

  the control panel. If the RT connection goes high then the detector 
  immediately performs a self test. If the test passes then the detector 
  immediately performs a self test, if the test passes then the relay changes 
  state for 3 seconds.

  

2.3 Failure of a test 

(See diagram         )

  If the test fails the LEDs flash alternately (See diagram         )
  If a valid alarm activation is processed then the detector will return to its 
  normal operation. In the unlikely event of a continuous test failure then 
  please contact Pyronix technical support.  

3. Relay modes  (Switch C)

ON =   Relay is in normally closed mode. (N/C)
OFF = Relay is in normally open mode. (N/O)

4. Digital signal processing settings  (Switch D & E)

PC 1     = 

One detection zone must be crossed.   

SPP+    = 

Two opposing detection zones must be crossed.   

PC 2     = 

Two detection zones must be crossed.   

SPP+1  = 

Two opposing detection zones and any other zone must be 

                 crossed.

5. Walk test LED enable (Switch F) 

ON   =   Walk test LEDs are disabled.
OFF =   Walk test LEDs are enabled.

  

5.1

 When the walk test LEDs are enabled three LEDs will illuminate in a 

  normal alarm activation. See diagram

 

  

5.2

 When the walk test LEDs are disabled the middle LED will illuminate 

  in a normal alarm activation. See diagram 

  

5.3

 The walk test LEDs will be automatically disabled after 10 minutes to 

  reduce power consumption.

6. C+ Latch terminal

This function allows an activated PIR to be identified after an alarm 
condition by a flashing LED, see diagram 

6.1 Connection

Connect (C+) to a PGM at the control panel programmed to be 12V after 
arming. To reset the latch memory, create a 5 second switch from OV to 
12V and back to 0V.

6.2 Pyronix Panels

Connect detector input C+ to a PGM output configured as C+ using a 
2K2 resistor from AUX+ to the PGM output.
To reset the latch memory enter the user code twice within 5 seconds.

7. RT Remote self test terminal

If remote self test is selected (switch B off), a self test can be initiated by a 
momentary switched 0 volt input. Refer to section 8.1 and 8.2

8. E- Remote LED enable terminal

To use the remote  LED enable feature switch A must be in the OFF 
position.

  

8.1 Connections

  To remotely enable LEDs, 0 volts must be applied to the E- terminal.

  

8.2  Pyronix Panels

  Connect detector input E- to a PGM output and configure as walk test.        

 

 

 

                            

       

 

      

       

  

 

 

 

 

 

    

     

OPTIONAL TAMPER UNIT

Note: The Kudos detector may be fitted with an optional back tamper, which is sold separately.

SPECIFICATIONS (QUICK REFERENCE)

Model:                             

Kud

o

s

Casing:                            White3mm ABS Back / Front cover

                                        White 3mm HDPE lens cover, 0.7mm in faceted area      

Lens:                               Volumetric: 20m, 74 zones, 7 planes, 2.4m mounting height

                                        Curtain: 25m, 24 zones, 6 planes, 2.4m & 5m mounting height 

                                        Long range: 45m, 46 zones, 6 planes  2.4m mounting height 

                                       .

Detection method:           Low noise dual element pyroelectric sensor             

Digital signal processing:SPP+ , SPP+1, PC 1, PC 2.

Detection speed:             0.3 - 3.0 m/s

Operating  Voltage:         9-16 VDC        

Current consumption:     22mA Quiescent

@13.8V                          48mA Walk test mode

                                       105mA self test (short burst per test)

          

Relay Output:                 60Vdc, 50mA (42.4Vac peak)                

Mounting Height:            1.8 - 2.4m           

Tamper Switch:              Normally closed voltage free contacts 

                                       (12V 50mA max rating)

0

0

0

0

Storage Temp:               -40   C / 80   C (-40   F / 176   F )    

0 0

0

0

Operating Temp:           -30  C / 70   C (22   F / 158   F )            

Emissions:                     EN55022 Class B                                             

Immunity:                       To new European Standard EN50130-4

Accessories:                  Optional back tamper

C

Installation

     Mounting with back tamper

 

            Flat against a wall

            Corner mounted

            45 Degree o   all

  n w

     Cut out the tamper position
     required, using scalpel or sharp 
     utility kni e

f

     Orientation of tamper unit

            Left hand side

            Right hand s de

i

    

 
     Ensure tamper switch lever
     is  orrectly orientated

 

c

      osition switch and tamper plate.

  P

     Position unit within detector,

 

     using step three, for orientati n

o

     of unit. 

     Ensure clip fixtures are located
     in the correct p sition, on the 

  o

     outer surfac   f the casing.

e o  

 

 

  

H5

H3

H2

RINS 411-7

H5

H4

Kudos 

Including 3 Lens Variants

0C03

PYRONIX LTD                                                          

R

This product is approved for use in the 

Residential, Commercial and Light Industrial Environment.

Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND

Technical help line (UK only): 0870 122 3360

This is a national rate line

[email protected]

 www.pyronix.com

This product complies with TS50131-2-2. at security grade 2, 

environmental class 2.

UK = Suitable for use with systems installed to PD6662:2004 (AMD)

EXPORT = Suitable for use with systems installed to EN50131-1

2

TS50131-2-2
EN50131-1
PD6662:2004

Security Grade 2
Environmental Class 2