background image

Wet-Sander

AFD1100

Manual

PAR01330-2

January, 2000

 

Dallas, Texas

Summary of Contents for AFD1100

Page 1: ...Wet Sander AFD1100 Manual PAR01330 2 January 2000 Dallas Texas...

Page 2: ...red to 5 m and a 0 3 micron oil mist separator Non compliance with these requirements will void the manufacturer s warranty See Section 4 3 All fasteners mounting holes and pipe threads on this tool a...

Page 3: ...nts 1 0 LIMITED WARRANTY 1 2 0 GENERAL OVERVIEW 3 3 0 INSTALLATION 4 3 1 Mounting the AWS1100 4 3 2 Air Supply 5 3 3 Water Connections 7 3 4 Electrical Connections 8 4 0 Wetsanding Pad Removal and Rep...

Page 4: ...A IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE Some states do not allow limitations on how lon...

Page 5: ...and maintenance of the product as described in the owner s manual s When warrantor will perform repair or replacement under this warranty Repair or replacement will be scheduled and serviced according...

Page 6: ...d allows the unit to automatically compensate for gravitational and inertial effects to maintain the desired sanding force Finally a linear potentiometer located within the pneumatic actuator senses t...

Page 7: ...r supplied is required to securely attach the Mounting Plate to the robot s mounting flange These flat head screws must be installed per the robot manufacturer s instructions To mount an AWS1100 first...

Page 8: ...uld not be used as a pressure regulator device The Air Supply System should be configured as shown in Figure 2 3 m OIL MIST SEPARATOR AIR REGULATOR PRESSURE GAUGE 5 m FILTER SHUT OFF VALVE 80 psi 5 5...

Page 9: ...and that there is a minimum of 80 psi 5 5 bar at the Air Supply Port If a minimum air pressure of 80 psi 5 5 bar cannot be achieved then an auxiliary air compressor or booster pump must be installed T...

Page 10: ...e Without proper water pressure the bearing will come into contact with the linear shaft and cause excessive friction and force errors The second connection is an 8mm push lock fitting supplying water...

Page 11: ...LER CABLE Figure 5 Electrical Cable Connections 4 0 Wetsanding Pad Removal and Replacement The AWS1100 Wet Sander accepts standard 5 8 11 right hand threaded wet sanding pads To remove a worn Wet Sand...

Page 12: ...50 C Humidity 5 to 95 Non Condensing Supply air Non lubricated Dry 5 m Filtered 80 90 psi 5 5 6 2 bar 2 SCFM 28 l min Hydrostatic Bearing 60 psi 4 1 bar Min 100 psi 6 9 bar Max Water Pressure Specifi...