background image

For correct operation & installation, it is essential to observe these instructions.

AS/NZS 3497

Licence No. WM 74617

Australian Certification 

Services

JUL2021

User Guide

Quick Twist Filter System with Tripla LED Mixer Tap

Z1 Tripla Series

Summary of Contents for Tripla Z1-T1

Page 1: ...ation installation it is essential to observe these instructions AS NZS 3497 Licence No WM 74617 Australian Certification Services JUL2021 User Guide Quick Twist Filter System with Tripla LED Mixer Tap Z1 Tripla Series ...

Page 2: ...xer Tap Connections 7 Battery Installation 9 Replacement of Ceramic Disc Cartridge s 10 PART 2 Filter Cartridge Installation Installation Requirements 10 Installation Procedure 11 Cartridge Installation Changeout 12 Use Guidelines 14 WELS Ratings 15 Tripla T1 Parts Description 16 Tripla T2 Parts Description 17 Tripla T3 Parts Description 18 Tripla T4 Parts Description 19 Tripla T5 Parts Descriptio...

Page 3: ...esigned to run economically for many years dependent on the initial installation and periodical maintenance Flush systems for 10 minutes after any period of non use more than 2 days For a period of non use of 2 weeks or more it may be necessary to replace cartridge Tap Surface should only be cleaned with liquid detergent or soap and water Under no circumstance should any abrasive or acid base clea...

Page 4: ...act your plumbing supply store or your local Puretec stockist Important We do not recommend the dismantling of any internal part of the mixer as this will breach your warranty Technical Information Puretec mixers can be used in conjunction with Pressure storage hot water system Any mains water pressure not exceeding 500 kPa Maximum hot water temperature of 60 C Instantaneous hot water system Any f...

Page 5: ...on COLD Metal Washer Rubber Washer Locking Nut Retainer Screw Fig 1 Mixer Tap Installation Guide PART 1 Note It is important to flush out the supply pipes to the mixer before connecting the flexible hoses with the initial installation so no foreign matter can enter into the cartridges A Puretec Water Filter is highly recommended for product longevity ...

Page 6: ...er Spacer Locking Nut Retainer Screw Zinc Spacer Fig 2 Tap Assembly O Ring Brass Base 1 2 Step 1 Connect the hoses to the faucet and tighten them Refer to page 7 for connection patterns Only use hand to screw the flexible hose Do not over tighten Don t use any tools Step 2 Put brass base with o ring to the bottom of the faucet Basin or Sink 33mm dia Hole Step 3 Put the hoses through the basin or s...

Page 7: ...ck Twist Water Filter System with Tripla LED Mixer Tap Retainer Screw HOT Water Connection COLD Water Connection Water Filter Connection For Z1 T1 Z1 T2 Fig 3 Water Connection Patterns Mixer Tap Connections ...

Page 8: ...Operation Manual Copyright Puretec Pty Ltd 2021 Retainer Screw HOT Water Connection COLD Water Connection Water Filter Connection For Z1 T3 to Z1 T6 Retainer Screw Fig 4 Water Connection Patterns Mixer Tap Connections ...

Page 9: ...the faucet canopy Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes or 12 months Please change the battery when changing the filter cartridge s Positive side up Negative on the PCB 4 Blue light flashes during normal operation This product contains a button battery Accidental ingestio...

Page 10: ...k nut Lift out old cartridge and clean inside making sure no old O rings are still stuck inside cartridge housing Insert new cartridge making sure O rings on bottom of new cartridge have not fallen off and lugs in bottom of cartridge line up with holes in cartridge housing Now you can tighten lock nut with a torque wrench to 14 newton meters then reinstall dome cap lever screw and hot and cold wat...

Page 11: ...ERAGE 1 Select suitable location that is close to the point of filtered water delivery eg sink Remember to allow access room for changing filters and a suitable place where water spillage will not cause damage Location should not be in direct sunlight 2 Isolate water supply and fit SmartTee to the mains cold supply ready for Mixer and Filtered water line connections 3 Connect the SmartTee to the m...

Page 12: ...aks If leaks occur repeat step 3 If leaks persist isolate the water supply to the system discontinue use and call your supporting dealer 6 Flush filter for 5 minutes before use or until water runs clear Use Guidelines Minimum operating pressure 172 kPa Maximum operating pressure 500 kPa Do not allow exposure to temperatures below 0 C protect from freezing Maximum operating temperature 38 C Nominal...

Page 13: ...sure tube is pushed in to tube stop 3 Tube is secured in position Fig 6 How To Use Quick Connect Fittings Fig 5 Installation Diagram No DESCRIPTION 1 SmartTee 2 White Tubing 3 Pressure Limiting Valve Multivalve 4 Z1 R Filter Cartridge 5 Mounting Bracket Head 6 Stem to 1 4 Tube Reducer 7 Nut 8 Filtered Water Flexible Hose Plain 9 Cold Water Flexible Hose Blue Streak 10 Hot Water Flexible Hose Red S...

Page 14: ...h the collet against the quick connect nut and slide tube out of fitting 3 The fitting grips before it seals Ensure the tube is pushed all the way into the tube stop 4 Once the tube is secured in position turn the quick connect nut clockwise to secure Note Hand tighten only Do not overtighten 1 Turn the quick connect nut on the SmartTee anticlockwise to release the collet 5 Turn the quick connect ...

Page 15: ...15 Quick Twist Water Filter System with Tripla LED Mixer Tap TRIPLA T1 WELS Rating for Tripla Taps TRIPLA T2 TRIPLA T3 TRIPLA T4 TRIPLA T5 TRIPLA T6 WELS Rating ...

Page 16: ...33 Aerator Cap 16 Rubber Washer 15 2 Nut 19 Rubber Washer 20 Stainless Washer 21 Brass Nut 18 Screw 35 Screw 39 Display 9 Cover Stem 7 Plunger 11 Spout 11 1 Body 14 Body Stem 15 1 Body 11 2 Tube 11 3 Inner Tube 11 4 Connector 4 Cap 6 Cap 8 Stem Cartridge 45 Flexible Hose Red Parts Description 17 Housing 36 Magnetic Seat 40 Circuit Board 37 Magnet 43 Flexible Hose Plain alternate hose with larger f...

Page 17: ... Strong Magnet 35 Handle Cap 7 Cover Stem 12 Body Stem 38 O Ring 41 Battery Seat 40 Circuit Board 5 Plunger 9 Spout 2 Cap 4 Cap 6 Stem Cartridge Parts Description 13 1 Body Stem 13 2 Body Stem 9 2 Brass Tube 9 4 Connector 9 3 Inner Tube 26 Aerator Insert 29 Aerator Insert 27 Aerator Cap 30 Aerator Cap 42 Alternate Flexible Hose Plain alternate hose with larger filter connection supplied but not re...

Page 18: ...t 28 Body 35 Body 36 Nut 23 3 Inner Tube 23 2 Tube 11 Screw 24 Cap 1 Washer 2 Aerator Insert 3 Aerator Cap 23 1 Body 27 O Ring 29 O Ring 30 Connector 30 2 Cartridge 31 Plunger 32 Cap 37 Stopper 12 Strong Magnet 14 Battery Seat 15 Circuit Board 13 Magnet Seat 46 Flexible Hose Red 44 Flexible Hose Plain 45 Flexible Hose Blue 47 Alternate Flexible Hose Plain alternate hose with larger filter connecti...

Page 19: ...e Cap 29 Body 38 1 Body 38 2 Nut 30 O Ring 31 Connector 32 Stem 33 Plunger 34 Cap 39 Stopper 40 Washer 17 Circuit Board 10 Cap 13 Display 16 Screw 11 O R ing 12 Screw 15 Washer 21 Plunger 22 Turn Stem Body 23 Stem Post 24 Upper 25 Lower 14 Handle Cap 18 Battery Seat 20 Magnet Seat 19 Strong Magnet 26 Seat 27 Stopper 26 Seat Parts Description 48 Alternate Flexible Hose Plain alternate hose with lar...

Page 20: ...e 36 Screw 37 Handle Cap 29 Body 38 1 Body 38 2 Nut 30 O Ring 31 Connector 32 Stem 33 Plunger 34 Cap 39 Stopper 40 Washer 17 Circuit Board 10 Cap 13 Display 16 Screw 11 O Ring 12 Screw 15 Washer 21 Plunger 22 Turn Stem Body 23 Stem Post 24 Upper 25 Lower 14 Handle Cap 18 Battery Seat 20 Magnet Seat 19 Strong Magnet 26 Seat 27 Stopper 26 S eat 48 Alternate Flexible Hose Plain alternate hose with la...

Page 21: ...40 Handle Cap 32 Body 41 Body 41 1 Nut 33 O Ring 34 Connector 35 Stem 36 Plunger 37 Cap 42 Stopper 43 Washer 20 Circuit Board 13 Cap 16 Display 19 Screw 14 O Ring 15 Screw 18 Washer 24 Plunger 25 Turn Stem Body 26 Stem Post 27 Upper 28 Lower 17 Handle Cap 21 Battery Seat 23 Magnet Seat 22 Strong Magnet 29 Seat 30 S Topper 29 Seat Parts Description 48 Alternate Flexible Hose Plain 49 Flexible Hose ...

Page 22: ...uidelines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is passed N A II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria YE...

Page 23: ...equential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the warranties need to be approved by Puretec to ensure product was not incorrectly used installed or claimed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred All installation and service work should be...

Page 24: ......

Reviews: