background image

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Incorrect disposal can cause adverse effects to the environment. 

Dispose of the device components and packaging material in accordance with regional 
environmental regulations including regulations for electrical / electronic products. 

Transducers/Radars 

Remove power, disconnect the Transducer/Radar, cut off the electrical cable and 
dispose of cable and Transducer in accordance with regional environmental regulations 
for electrical / electronic products. 

Controllers 

Remove power, disconnect the Controller and remove battery (if fitted). Dispose of 
Controller in accordance with regional environmental regulations for electrical / 
electronic products.  

Dispose of batteries in accordance with regional environmental regulations for batteries. 

EU WEEE Directive Logo

 

This symbol indicates the requirements of Directive 2012/19/EU regarding the treatment 
and disposal of waste from electric and electronic equipment. 

 

Disposal Guidance

 

Contact Information

 

Cardinal Building 
Enigma Commercial Centre 
Sandys Road 

 

 

 

Tel: +44 (0)1684 891371 

Malvern   

 

 

 

Fax: +44 (0)1684 575985 

WR14 1JJ 

 

 

 

Email: 

[email protected]

 

United Kingdom   

 

 

https://www.pulsar-pm.com

  

 
 

P.O Box 5177 

4565 Commercial Drive 

Suite 105 

 

 

 

Tel: +1 850 279 4882 

Niceville  

 

 

 

Fax: +1 850 279 4886 

FL 32578 

 

 

 

Email: 

[email protected]

  

USA 

 

 

 

 

https://www.pulsar-pm.com

  

  

© Pulsar Process Measurement Ltd 2018 

 

Pulsar Process Measurement Ltd operates a policy of constant development and improvement and 
reserves the right to amend technical details as necessary.

 

 

mmWAVE   

  

Radar (Ex mb) 

mmWAVE-is Radar (Ex-ia) 
ATEX/IECEx Installation Guide 
 

Full manuals available at: 

www.pulsar-pm.com/instrumentation/support/downloads/manuals.aspx

  

 

 

 

M-dBR-0-003-1P 

Description

 

The mmWAVE Radar (dBR16 and dBR8) are new FMCW non-contacting radar level 

measuring sensors designed to meet the requirements of today’s demanding process 

level measurement applications for liquids and solids. 
The mmWAVE Radar features an innovative design, which has no extra antenna 

requirements, that can offer very high performance and effective radar level sensing.  It 

gives all the advantages associated with radar technology and offers best-in-class 

performance with a narrow beam angle and a range from 0.077 to 8 metres for a dBR8, 

and 16 metres for a dBR16.  The signal emanates from the curved face of the radar, but 

for the purposes of measurement it is measured from the drip shield. 
Housed with a robustly engineered enclosure, the mmWAVE Radar is designed for easy 

retrofitting to any of Pulsar’s many controllers (including the Ultimate, Ultra series and 

BlackBox) all as a microwave alternative to a dB transducer.  Using the latest versions of 

firmware: Ultra 7.5.1, Ultra Twin 1.5.1, BlackBox 2.1.1 and Ultimate 2.1.10 and onwards 

the mmWAVE radars can be programmed for use in P101 (transducer).  For further 

information on setting up the Radar with a controller please consult Pulsar for 

assistance. 

Two ATEX / IECEx approved versions are available: 

 

1. 

Ex ia (IS): for zones 0,1 and 2 

3-wire, for use with Pulsar’s standard range 

of controllers. Tamb. -20°C to +80°C 

2. 

Ex mb: for zones 1 and 2 

3-wire, for use with Pulsar’s standard range 

of controllers. Tamb. -20°C to +80°C 

Standard cable lengths:10, 20 or 30m. 
Process Connection: 1” BSP or NPT thread. 
A range of mounting brackets are available. 
Ingress Protection: IP68 / NEMA 6P. 
Not all mmWAVE sensors are ATEX / IECE certified; check the label for approval 

details. 

Labels for the two versions of protection are show below: 

Ex ia (IS) 
 
 
 
 
 

 

 

Ex mb 
 
 
 
 
 
 

 

The ‘X’ in the certification numbers indicates that certain special conditions apply: 
See the EU declaration of conformity in this document for more information. 

 

Enclosure material 

Valox 357U 

Enclosure protection 

IP68 / NEMA 6P 

Mounting connection 

Via 1” BSP or NPT mounting thread 

Dimensions 

130x90mm (0.42x0.29 ft.) maximum 

Weight 

1.1kg (2.4lbs) 

Measurement range 

dBR16: 0.077 to 16m (0.25 to 52.49 ft.) 
dBR8:   0.077 to 8m (0.25 to 26.25 ft)  

Cable extensions 

3-core screened 

Maximum separation 

Exmb: 500m (1,640 ft.), Exia: 300m (984 ft.) 

Frequency 

V-Band 

Accuracy 

±2mm 

Repeatability 

±1mm 

Radio approval 

EN302-729:2016 (Level Probing Radar) 

Minimum distance between targets 

0.15m (0.49 ft.) 

Min and Max temperature 
(electronics) 

 
-20°C to 80°C (-4°F to 176°F) 

Supply voltage 

28V DC max 

Power 

Typically, 0.6W 

 

 

Key Advantages of mmWAVE

 

Radar

 

 

World beating long range non-contact radar level sensor. 

 

Class-leading performance, range and exceptionally narrow beam angle. 

 

Excellent accuracy and repeatability. 

 

State of the art, proven, algorithms for ignoring unwanted targets (DATEM). 

 

Measure contents through non-conductive container walls. 

 

Unaffected by fog, haze, mist or rain. 

 

Independent of ambient temperature. 

 

Immune to inert gas, vapour, steam or pressure. 

 

Direct retrofit to Pulsar controllers. 

 