background image

 

F

F

l

l

u

u

o

o

r

r

P

P

e

e

n

n

 

 

F

F

P

P

 

 

1

1

0

0

0

0

 

 

 

 

 

 

 

 

S

S

e

e

r

r

i

i

e

e

s

s

 

 

 

 

 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

 

 

For:

  

FluorPen FP 100 

FluorPen FP 100-MAX 

PAR-FluorPen FP 100-MAX-LM 

FluorPen FP 100-B 

FluorPen FP 100-U 

FluorPen or PAR-FluorPen  

                    with detachable leafclips 

 

 

 
 
 

 
 

 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

PSI (Photon Systems Instruments), spol. s r.o.  

Drasov 470, 664 24 Drasov, Czech Republic 

 http://www.psi.cz 

Summary of Contents for FluorPen FP 100

Page 1: ...io on n M Ma an nu ua al l For FluorPen FP 100 FluorPen FP 100 MAX PAR FluorPen FP 100 MAX LM FluorPen FP 100 B FluorPen FP 100 U FluorPen or PAR FluorPen with detachable leafclips PSI Photon Systems...

Page 2: ...ing 26 8 A General Information 26 8 B USB Pairing 26 9 FluorPen Software 27 9 A Starting up 27 9 B Menu and Icon Explanation 28 9 C Example of Data Transfer and Visualization 30 9 D Explanation of OJI...

Page 3: ...compatible Memory Capacity Up to 4 Mb Internal Data Logging Up to 100 000 data points Display 2 x 8 characters LC display Keypad Sealed 2 key tactile response Keypad Escape Time Turns off after 3 minu...

Page 4: ...of Microsoft Corporation The Bluetoothmodule BlueNiceCom III is endowed with a declaration of conformity with the following norms EN 300 328 V1 6 1 2004 11 EN 301 489 1 3 V1 5 1 2003 12 EN 50371 Decem...

Page 5: ...values of 20 measurements Measured data are sequentially stored in the internal FluorPen or PAR FluorPen memory Data transfer to a PC is via USB or Bluetooth communication Comprehensive FluorPen 1 0...

Page 6: ...ght Curve and Photosynthetically Active Radiation PAR in the range from 400 to 700 nm Adapted for use with detachable leaf clips leaf clips sold separately FluorPen measures the following parameters F...

Page 7: ...s serve to describe adaptation of Quantum Yield to six or five different light levels see more in Chapter 8 F of this Manual PAR Photosynthetically Active Radiation Photosynthetically Active Radiation...

Page 8: ...communication only Bluetooth Communication Module FluorPen FP 100 B or FP 100 MAX only USB Communication Module FluorPen FP 100 U or FP 100 MAX only Other Accessories or Optional Features according to...

Page 9: ...Only in the PAR FluorPen FP 100 MAX LM Only in the FluorPen FP 100 MAX W supplied with a special open window leaf clip Leaf clip Menu key Set key Optical window Textile strap holder Light Meter Sensor...

Page 10: ...m dirt or moisture The damaged or dirty pad can be easily removed by tearing it off from the surface To affix a new one just remove the sheeting and stick the pad on cleaned and dried surface Be sure...

Page 11: ...luorPen FP 100 MAX D and PAR FluorPen FP 100 MAX LM D Sample holder is a clip for gentle fixing of a leaf sample and its short duration dark adaptation D version of the PAR FluorPen with detachable le...

Page 12: ...e yellow color represents the first level Sub Menus and their Options The green color represents the second level Sub Menus and their Options Full line arrows are used for the SET key Dashed line arro...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...h card Make sure that the PC s Bluetooth setting is discoverable meaning that it shows up when other devices search for nearby Bluetooth connections Consult the user guide for your PC or Bluetooth car...

Page 21: ...n mind that the FluorPen turns off automatically after about 3 minutes of no action Turning off the FluorPen always turns off Bluetooth Step 2 Starting the Bluetooth Application on Your PC Be aware th...

Page 22: ...that the FluorPen is in discoverable mode see Step 1 Step 4 Searching for a New Bluetooth Device Mark the following box My device is set up and ready to be found Select Next Step 5 Selecting the Fluo...

Page 23: ...3 Step 6 Starting the Pairing Process Your Bluetooth Pairing Passkey is 0000 Select Let me choose my own passkey Enter 0000 four digits Select Next Step 7 Completing the FluorPen Pairing Select Finish...

Page 24: ...e FluorPen press and hold the SET key Scroll to the Setting menu press the MENU key twice then press the SET key once Select BT_On to enable Bluetooth press the SET key Keep in mind that the FluorPen...

Page 25: ...her when the Bluetooth feature has been turned off in one or both of the devices or when the units move outside their operating range If the devices have been turned off simply turn them on and enable...

Page 26: ...ave these components 1 USB enabled FluorPen FluorPen FP 100 MAX and FluorPen FP 100 U include connector for communication by USB cable 2 USB cable 8 B USB Pairing Connect the USB cable to a computer a...

Page 27: ...e either USB or Bluetooth For USB connection you need to have the USB driver installed in your PC You find the driver on the installation disk USB driver folder If you check the Device Manager in Wind...

Page 28: ...the FluorPen memory Online Control Settings sound and time Attach GPS File Used for download data from GPS module Menu Setup Device ID Detects the Bluetooth connected device Update Firmware Used for s...

Page 29: ...gle If the box is checked all measured data are visualized in one graph i e the value of each new measurement is added to the currently used graph window If the box is not checked a new graph is opene...

Page 30: ...id an OJIP measurement Step 2 Click the Download icon or select Device Download Step 3 The Data table appears File name Time of experiment Measured parameter Experiment description Switch to graphic v...

Page 31: ...ocol Measuring by protocol export all protocols at once OJIP NPQ LC Selected only exports only one measurement that is selected by mouse otherwise it will export everything Source data exports raw dat...

Page 32: ...32...

Page 33: ...dV dt 0 M0 TR0 RC ET0 RC 4 F300 F0 FM F0 Area Area between fluorescence curve and FM background subtracted Fix Area Area below the fluorescence curve between F40 s and F1s background subtracted SM SM...

Page 34: ...34 Example of OJIP protocol...

Page 35: ...the duration of the light exposure and the dark recovery phase in the number and interval between pulses See table below Phase Duration of pulses 1st pulse Pulse interval NPQ1 Light 60s 5 7s 12s Dark...

Page 36: ...36...

Page 37: ...37 Example of NPQ1 protocol Example of NPQ2 protocol...

Page 38: ...in number and duration of individual light phases and light intensities of phases Phase duration Light intensities mol m 2 s 1 LC1 6 60s 10 20 50 100 300 500 LC2 5 30s 100 200 300 500 1000 LC3 7 60s...

Page 39: ...39...

Page 40: ...40...

Page 41: ...41 Example of LC1 protocol Example of LC2 protocol...

Page 42: ...42 Example of LC3 protocol...

Page 43: ...ased during the software update Before starting any software update export all your data from the FluorPen memory into your computer Step 1 Starting Update Select Setup Update Firmware Step 2 Selectin...

Page 44: ...44 Step 3 Finishing Upload Select OK to start uploading of the update The bottom bar indicates the upload progress Press OK to finish upload...

Page 45: ...ule might be connected to the device IMPORTANT INFORMATION For proper GPS reading the time in your FluorPen and in your computer must be synchronized Pre set time and time zone must correspond to GPS...

Page 46: ...rgeable NiMH 2 Device settings 1 Hold 2 After the device is on it begins acquiring satellite signals The device may need a clear view of the sky to acquire satellite signals 3 You can check current po...

Page 47: ...luorPen time with the time of your PC Time must be set correctly witch respect to your time zone Step 2 GPS Positioning Switch the GPS module on and wait until the GPS position is fixed GPS green LED...

Page 48: ...dule and set your computer to FluorPen communication enable Bluetooth or connect to serial or USB port Step 2 Downloading FluorPen Data Start FluorPen program Connect FluorPen device Download Measured...

Page 49: ...C Communication is set properly if the hardware is recognized by your PC Step 4 Downloading GPS Data Select Device Attach GPS file to download data from the GPS module Step 5 Completing the Download S...

Page 50: ...de on site repair charges such as labor travel or other expenses associated with the repair or installation of replacement parts at the customer s site PSI repairs or replaces faulty instruments as qu...

Reviews: