background image

 

 

 

Mifare

®

 Configurable   

Sector Reader 

User’s Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV.C 

July 9, 2007 

Summary of Contents for Mifare MF7xx Series

Page 1: ...Mifare Configurable Sector Reader User s Manual REV C July 9 2007 ...

Page 2: ...ulti unit communication Features 1 Support MAD1 MAD2 standard and support customer MAD AID setting 2 Support Non MAD format with user defined sector number 3 Support Anti Collision Two cards together can be read at the same time 4 Support used card with data offset and length 5 Support Multi Sectors 6 Support Mifare Standard 4K or Mifare Standard 1K card 7 Each Reader with Reader ID for multi link...

Page 3: ...er Yes Auto Mode Get Application Sector Request Anticollision Is MAD Card AID Match Using MF700 Non MAD Sector Un know Read Sector Data Output Data No Tag Card On Reader No Yes No The MF700 will search the AID from mifare application directory MAD then got a correct sector number from MAD If the card is not a MAD card the MF700 will use the Non MAD Sector Setting by MF700 Utility About MAD please ...

Page 4: ...th zero 0 if shorter than Number of Bits Byte 0 Byte 15 Block 0 Data Info Block 1 Block 2 USER DATA Max 128 Bytes Application Sector Block 3 Data Info bit7 bit6 bit5 bit0 Data Type 11b Data Length Data Type is fixed with 11b which meets any other data type of Card Holder information as MAD standard And data length is including the data with ending zero 0 so the number of data byte sent by MF7XX is...

Page 5: ...er Brown LED BUZEER IN External LED BUZZER Control Connect To MF7XXKIT before configure the MF7XX Reader To configure the MF7XX reader you need connect the reader to the MF7XXKIT first as below CP GND D1 D0 RX TX VCC MF700KIT MF700 9VDC WAS T0029 BLACK WHITE GREEN BLUE YELLOW RED ORANGE BROWN Remark 2004 10 29 New Brown wire is for External LED Buzzer Control and Blue wire is keep in RS232 RX sign...

Page 6: ...and read the corresponding sector on the MAD card Non MAD Sector Default 0 When the card is Non MAD format MF7XX will only read the Non MAD Sector 1K Card Sector 0 15 4K Card Sector 0 39 For the Non MAD application user can freely define the Sector App Key KEY_A Default FFFFFFFFFFFF App Key must be the same as the KEY_A of the card issued This means MF7XX only can read the sector data on the card ...

Page 7: ... the Offset Max 255 and base from zero form the beginning of sector and set your data Length Max 128 Example If your card data in the grey grid of sector you have to set the Offset 17 and set the Length 20 AID Sector or Non MAD Sector Block 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Block 1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Block 2 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 ...

Page 8: ... Card Data Only a Card Data Only Read card sector data only If any error ex mifare key error reader will show Card Invalid status b Card Data or CSN Card Serial Number Read card sector data If any error ex mifare key error reader will send the CSN to host c CSN Only CSN read only Output Mode Default Once a Once Send data or CSN to host once b Continue Keeping sending data or CSN to host till card ...

Page 9: ...Off 1 31h Green LED ON 2 32h Green LED OFF 3 33h Red LED ON 4 34h Red LED OFF 5 35h Buzzer Beep 1 Time 6 36h Buzzer Beep 3 Time 7 37h Green LED ON with Beep 1 Time 8 38h Red LED ON with Beep 3 Time 9 39h All LED ON Orange Remark If Enable the RS232 Command Set Control for LED Buzzer the external LED Buzzer control with high low level control will be disable Read Idle Show LED color after power on ...

Page 10: ...ondition with Host status Disable Always disable the Brown wire Default LED Buzzer control by reader self High Active High Normal keep in Low Low Active Low Normal keep in High Remark If set Active Low you may have to connect brown wire to a pull up resistor 1K 10K with 5VDC Control Brown wire After Data Output The brown wire will be enabling after finished output the card data or CSN Default Any ...

Page 11: ...ur Host or Terminal It can be 26 to 128 Default 26 Include Reader ID1 is to set the Wiegand output data to include Reader ID when it is enabled Default Disable Bit Sequence is to set the Wiegand output data sequence it can be standard data sequence MSB first or Reverse data sequence LSB first Default Standard ...

Page 12: ... Default 10 Add Reader ID Add Reader ID into TK2 data Default Disable Sequence Set the TK2 data sequence Default MSB First Data Conversion Select card data format to convert a BIN to DEC Default card issue by Mifare Card Issuer Utility b Decimal String ex 123456 c BCD d Direct Memory Map e Bytes to DEC ...

Page 13: ... data packet with Reader ID 2 RS232 output data packet with Header Reader ID and Trailer Header Reader ID LSB Data Bytes MSB Trailer 3 ABA TK2 with Reader ID Remark MF7XX all configuration items are write only so any users can not read the configuration items from MF7XX to get the App Key that is very important to protect your App Key and all configuration items Standard Parity Even Reader ID MSB ...

Page 14: ... configuration on the MF7XX Utility software is made you should click Update Reader to download the current configuration to the MF7XX Reader 2 After MF7XX configuration is completed you may click Test to test MF7XX Reader 3 Get an issued mifare card to put on MF7XX reader to be read and see the output data on the window of MF7XX Output Test Wiegand 34 bits output data with standard bit sequence e...

Page 15: ...13 56MHz RF Distance2 50mm Using the MFA01 Mifare card of GIGA TMS INC DC Power 7 5VDC 12VDC Min 250mA 7 5V 150mA 12V Interface Wiegand 26 128 bits Standard Reverse RS232 2400bps 57600bps ABA TK2 40IPS Dimension H82 5mm x W46 5mm x D15 0mm Weight 120g Note 1 Mifare Class Mifare Standard 1K 4K Pro without Mifare Ultra Light 2 MF7XX RF distance can reach up to 50mm with MFA01 Mifare Standard 1K Card...

Page 16: ...imes for the MF7XX reader Data 1 Signal Data 0 Signal Tpw Tpi Tpw Tpi Pulse Times Symbol Description Typical Time Tpw Pulse Width Time 100us 3 Tpi Pulse Interval Time 1 9ms 3 Wiegand Packet Without Reader ID Standard Default Parity Even MSB Data Bits LSB Parity Odd Reverse Option Parity Odd LSB Data Bits MSB Parity Even Connect the Wiegand wires example as below The pull high resister must 10K Ohm...

Page 17: ...aded by the user with the leading edge negative of the Strobe CARD PRESENT Card Present will go low after flux reversals from the Reader Card Present will return high after the last flux reversal Connect the ABA TK2 wires example as below Clock White Data Green HOST Terminal Optional External LED Buzzer Control Brown Red Black MF700 9 12VD GND GND Card Present Orange 0 0 0 0 1 1 0 1 0 0 1 0 0 0 Le...

Page 18: ...MF7xx PROMAG REV C 18 ANNEX D RS232 Interface Connect the RS232 wires example as below HOST Terminal Optional External LED Buzzer Control Brown Red GND Black MF700 9 12VD GND GND TXD Yellow ...

Page 19: ...o control the LED Buzzer of MF7XX Examples as below Active High 1 Show External Invalid Status Data Output Alarm Control Brown 2 Show Card Valid Status Data Output Alarm Control Brown Note 1 Send one pulse to show the Extern Invalid LED Buzzer Status 2 Send three or more pulse to show the Card Valid LED Buzzer status 3 You can configure the LED Buzzer status by MF7XX utility Min 100ms Min 100ms ...

Page 20: ...mmer Card Issue and Utility Software DC Power Adaptor 9VDC for MF7XXKIT Mifare Standard 1K Card MF700 10 MF700 10 MF700 Configurable Reader Encrypt Version MF700KIT 10 MF700KIT WAS T0029 DISK5238 Power Adaptor Reader Kit MF7XX Configure Cable Card Issue and Utility Software DC Power Adaptor 9VDC for MF7XXKIT PCR310U 30 PCR310U DISK5238 Card Issue Programmer Card Issue and Utility Software MFA01 MF...

Page 21: ... make sure they were power on Step 1 Input your account UserName and Password Note Contact us to get your account when needed Step 2 Click Start Check to automatically check the firmware version from our FTP server Note 1 The WebISP will auto scan all Comm ports to search the reader or programmer 2 The WebISP will show the Update Information and list the update history Step 3 If your reader s or p...

Page 22: ...eat step 2 to update other readers or programmers Step 5 Check Upgrade Update Files list to download the new and related software or utility to meet the updated firmware Note Click the new software or utility at Upgrade Update Files to start downloading Update finished ...

Page 23: ...Step 1 Only connect PCR310 to PC without any MF7XX Reader Click Auto Scan then found the PCR310 Select the MF700 Series option and Click OK Step 2 Click Configure Card to using current settings to creating a Configured Card Step 3 Put a new Mifare Card on PCR310 and Click Create to Create the Configured Card ...

Page 24: ...06 Add Direct Memory Map option item for Data Conversion of ABA TK2 Firmware Version PGM T0724 V1 0R4 DISK 5238 REV C Mifare Reader Utility V1 0R1 Rev C July 9 2007 Add Configured Card function for Update Reader via reading Configured Card Firmware Version PGM T0724 V1 1R0 DISK 5238 REV H Mifare Reader Utility V1 0R10 ...

Page 25: ...MF7xx PROMAG REV C 25 PROMAG GIGA TMS INC http www gigatms com tw mailto promag gigatms com tw TEL 886 2 26954214 FAX 886 2 26954213 Office 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Taiwan ...