background image

USER MANUAL

REV.01-04/22

English version

EclExpo 

Flood300VW

300W  asymmetric  LED  floodlight,  with 

Variable White CCT 2,700K - 6,500K

Summary of Contents for EclExpo Flood300VW

Page 1: ...USER MANUAL REV 01 04 22 English version EclExpo Flood300VW 300W asymmetric LED floodlight with Variable White CCT 2 700K 6 500K ...

Page 2: ...r l All right reserved Music Lights Via A Olivetti snc 04026 Minturno LT ITALY Thank you for choosing PROLIGHTS Please note that every PROLIGHTS product has been designed in Italy to meet quality and performance requirements for professionals and designed and manufactured for the use and application as shown in this document Any other use if not expressly indicated could compromise the good condit...

Page 3: ...THE DMX TERMINATION 10 DMX ADDRESSING 10 OPERATION AS A WIRELESS TRANSMITTER 10 Unlinking the transmitter 11 DMX TO WDMX TX 11 OPERATION AS A WIRELESS RECEIVER 11 Reset the receiver 11 WDMX TO DMX RX 11 8 CONTROL PANEL 12 DISPLAY AND BUTTONS LAYOUT 12 ROTATORY KNOB LAYOUT 12 9 MENU STRUCTURE 13 10 RDM FUNCTIONS 16 11 SHORTCUTS 17 12 ERRORS 17 13 DMX CHARTS 18 13 ACCESSORIES INSTALLATION 21 ANTI GL...

Page 4: ...bles are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are damaged defective deformed or showing signs of overheating Do not reapply power until repairs have been completed Refer any service operation not described in this manual to PROLIGHTS Service team...

Page 5: ...maintenance are not covered by the product warranty T 90 C c Temperature of the external surface The surface of the fixture can reach up to 90 C 194 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling Only technicians who are authorized by PROLIGHTS or Authorised service ...

Page 6: ...plied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS 2014 53 EU Radio Equipment Directive RED The products to which this manual refers comply with UL 1573 CSA C22 2 No 166 Stage and Studio Luminaires and Connector Strips UL 1012 CSA C22 2 No 107 1 Standard for power units other than class 2 FCC Compliance This ...

Page 7: ...p PwCon MXW 16A 3p PwCon FXW L 3m 9513FXWL03 ass 3x2 5mm TH07 cable 16A 3p 230V CEE plug MENAC3FXW socket L 3 m 9533FXWL03 ass 3x2 5mm TH07 cable SHUKO plug MENAC3FXW socket L 3m RSR0630A B steel security cable for hanging bodies inox steel shackle L 60 cm silver black C6002 slim aluminium clamp 200 kg loading 48 51 mm tubes M10 bolt FCLEXPOFL300VW flight case for 6 pcs of ECLEXPOFL300VW ECLEXPOFL...

Page 8: ...ments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping the fixture to a truss or other structure at any angle use clamps of half cou pler type Do not use any type of clamp that does not completely encircle the structu...

Page 9: ...an external battery then connect the product to an external battery 24 36V into the dedicated XLR4p socket to disconnect power disconnect the Battery from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 240 Vo...

Page 10: ...0 240V 50 60Hz 5 POWER OUT power output for connection of multiple units in series 6 ROTATORY KNOBS for product stand alone control operations 7 USER INTERFACE with display and buttons for access to the control panel functions 8 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 9 DMX OUT 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 10 ANTENNA of Wireless DMX Receiver internal module Fig 03 3 4 5 6 7 1 6 8...

Page 11: ...N DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male connector XLR socket Run the data link from the product XLR output female connector XLR socket to the DMX input of the next fixture Terminate the data link by connecting a 120 Ohm signal termination If a splitter is used terminate each branch of the link Install a DMX termination plug on the last fixture on...

Page 12: ...ble user settings through the MENU can also be set when the product is disconnected from the Main through the internal battery backup All that is needed is to press and hold the button ENTER to momentarily enable the display and enter in the settings Once the required operations have been executed the display will switch off again after few seconds of being inactive OPERATION AS A WIRELESS TRANSMI...

Page 13: ...m 2 Use UP DOWN buttons for select Wireless then press ENTER to confirm 3 Push ENTER button on WDMX ON OFF function and enable it to ON 4 Select WDMX mode and set it on Receiver please note that WDMX mode will be available only if WDMX ON OFF is set to ON 5 Enable RX RESET to ON to reset the receiver please note that RX RESET will be avaible only if WDMX mode is set to Receiver 6 On the transmitte...

Page 14: ...us menu window UP Browse upwards through the menu list and increases the numeric value displayed DOWN Browse downwards through the menu list and decreases the numeric value displayed ENTER Used to confirm the current menu or confirm the current function value or option within a menu ROTATORY KNOB LAYOUT The product is equipped with rotatory knobs for manual control of the product those are enabled...

Page 15: ...on transmitter RX reset On Off Total reset of the receiver RX reset unlocks only if WDMX mode is receiver DMX to WDMX TX On Off Enable Disable the transmission of the dmx from the transmitter to the receiver via wdmx WDMX to DMX RX On Off Enable Disable the retransmission of the DMX from the receiver to the other units connected by cable to the re ceiver itself 2 SETUP SCREEN BACKLIGHT ON Allows y...

Page 16: ...ode HIGH SILENT OFF OUTPUT CONTROL CONSTANT Ouput power will be reduced instantly in order to keep output constant DYNAMIC Ouput power will be reduced in time according to fixture temperature FACTORY RELOAD ON To reset the unit to factory default settings OFF 4 INFORMATION INFORMA TIONS DEVICE TIME FIXTURE HOURS TOTAL To view infromation about the unit PARTIAL CURRENT HOURS TOTAL PARTIAL SOURCE HO...

Page 17: ...alue WW CW Use the rotary knob 1 and 2 to set the WW and CW value STATIC FIXED COLOR WW DIMMER 000 255 Select of the following predefined color combination and its Dimmer value After enabled this mode the unit will be automatically assigned as Master CW WW CW STROBE 000 255 COLOR TEMPERATURE 2700K DIMMER 000 255 Select a predefined White preset 2800K 3000K 3200K 3500K 4000K 4500K 5000K 5600K 6000K...

Page 18: ...ESCRIPTION 0x0344 x x OUTPUT_RESPONSE_TIME 0x0345 x x OUTPUT_RESPONSE_TIME_ DESCRIPTION 0x0346 x MODULATION_FREQUENCY 0x0347 x x MODULATION_FREQUENCY_ DESCRIPTION 0x0348 x Sensors SENSOR_DEFINITION 0x0200 x SENSOR_VALUE 0x0201 x x RECORD_SENSORS 0x0202 x BURN_IN 0x0440 x x PROLIGHTS EclExpo Flood300VW 16 10 RDM FUNCTIONS The product can communicate using RDM Remote Device Management protocol over ...

Page 19: ...lave 0 Standalone Mode 0x82EC x x 0 3 0 Static 1 CCT preset 2 Manual WW CW 3 FX 1 Static Colors 0x82BE x x 0 2 0 Full WW 1 Full CW 2 Full WW CW 1 White Presets 0x82BF x x 0 9 0 2700K 1 2800K 2 3200K 3 3500K 4 4000K 5 4500K 6 5000K 7 5600K 8 6000K 9 6500K 4 Manual WW 0x82E2 x x 0 255 Set level of WW in Manual WW CW mode 255 Manual CW 0x82E3 x x 0 255 Set level of CW in Manual WW CW mode 255 FX Sele...

Page 20: ...INE DIMMER FINE 3 COLD WHITE STROBE STROBE 4 CCT CCT 5 CCT FINE CCT FINE 6 CROSSFADE 7 WARM WHITE 8 WARM WHITE FINE 9 COLD WHITE 10 COLD WHITE FINE 11 FUNCTION 13 DMX CHARTS ID DMX Mode 1 UNO 2 DUO 3 BASIC 4 STANDARD 5 EXTENDED RDM Personality ID List RDM Model ID 0xD072 PROLIGHTS EclExpo Flood300VW 18 ...

Page 21: ...00K 4300K 4400K 4400K 4500K 4500K 4600K 4600K 4700K 4700K 4800K 4800K 4900K 4900K 5000K 5000K 5100K 5100K 5200K 5200K 5300K 5300K 5400K 5400K 5500K 5500K 5600K 5600K 5700K 5700K 5800K 5800K 5900K 5900K 6000K 6000K 6100K 6100K 6200K 6200K 6300K 6300K 6400K 6400K 6500K 0 7 7 13 13 20 20 27 27 34 34 40 40 47 47 54 54 60 60 67 67 74 74 81 81 87 87 94 94 101 101 107 107 114 114 121 121 128 128 134 134 ...

Page 22: ...Lost Blackout DMX Lost Hold DMX Lost Stand Alone Fan Auto Fan Silent Fan High Fan OFF Stand Alone Master Dmx Stand Alone Master No Dmx Stand Alone Slave Stand Alone Effect Stand Alone CCT Stand Alone WW CW Stand Alone White Presets Stand Alone Fixed Color Stand Alone Color Temperature Stand Alone Manual Color Menu Stand Alone Output Control Constant Output Control Dynamic RESERVED FACTORY DEFAULT ...

Page 23: ...WFFB W OPTIONAL Anti Glare Louvre Filter Frame DETAIL 1 DETAIL 2 DETAIL 3 Insert the anti glare louvre into the slot DETAIL 1 Pull the knob out DETAIL 2 and insert the acces sory filter frame from the top into the guide on the hardware of the unit DETAIL 3 Then release the knob DETAIL 3 NOTE To remove the accessory reverse the procedure Fig 08 ...

Page 24: ... ECLEXPOFL300VWBDB W OPTIONAL DETAIL 2 DETAIL 1 Unscrew the knob of the barndoor accessory DETAIL 1 Then mount the barndoor by screwing the knob with the hole on the unit hardware DETAIL 2 NOTE To remove the accessory reverse the procedure Fig 09 ...

Page 25: ...nd qualified personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lifetimes However optical components are subject to wear and tear over the life of the product resulting in gradual changes in colours over many thousands of hours of use The extent of wear...

Page 26: ...nnectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact PROLIGHTS Service or an authorized service partner M...

Page 27: ......

Page 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190 ...

Reviews: