background image

PRO. SIS. TEL.

Produzione sistemi telecomunicazioni

 

Antenna Rotator

Azimuth “D” DC version 

User’s manual

Rev.1.7b-usb

     

FCC

C.da Conghia 298 - 70043 Monopoli BA Italy

Tel-Fax ++39 080 8876607 

E-mail:[email protected]

Copyright  ® PRO.SIS.TEL. 2017

Summary of Contents for PST

Page 1: ...ione sistemi telecomunicazioni Antenna Rotator Azimuth D DC version User s manual Rev 1 7b usb FCC C da Conghia 298 70043 Monopoli BA Italy Tel Fax 39 080 8876607 E mail prosistel prosistel it Copyright PRO SIS TEL 2017 ...

Page 2: ...f transport or insurance for material returned to our workshops 5 The manufacturer is not responsible for personal injury or property damage resulting from improper or careless use of the product 6 All product is tested after assembly and is supplied without defect We exclude the substitution or the prolongation of warranty for a possible damage 7 After the 2 years warranty period maintenance or r...

Page 3: ... for antenna rotator Precautions WARNING never connect or disconnect rotor cable or USB connectors while power is on This may results in electrical shock or burn Table of contents Section 1 Description Section 2 Installation and use Section 3 Principle of operation Section 4 Technical specifications Section 5 CD Appendix 1 Declaration of conformity Appendix 2 Warning Table Note Last up date 28 Mar...

Page 4: ...ay The display will show the current bearing in degrees When the preset knob is turned the display will show the preset bearing The decimal points on the LED display blink when you turn the target position knob on the front panel rotation begins and is in progress when rotation is complete At that time the display will blink for the programmed delay time before further rotations are permitted Note...

Page 5: ...nually only Absolute or relative display mode Entering in Absolute mode The controller uses an ADC which accepts 0 5V voltages The antenna position voltage readout is mapped to be inside the 0 5V range In the absolute mode the display shows directly the rotator position expressed in absolute degrees you read values from 0 to 500 In the other operational modes north south stop the absolute readings...

Page 6: ...tive There are four switches 1 select the source of the three following parameters if ON the source is the other three switches status otherwise the relative EEPROM contents modifiable through the W command 2 operating mode if ON is north stop otherwise is south stop 3 rotation range if ON the rotation range is 0 to 500 absolute degrees otherwise is 70 to 430 absolute degrees 4 PWM if ON the PWM i...

Page 7: ...ided This allows you time to finalise the preset position before the rotator starts to turn The default is 3 seconds which may be altered in the sofware PWM duty cycles This feature controls the accelleration deceleration of the rotator between rest and full rotation speed This feature is kind to your antenna system as it gives smooth starting and stopping of your antenna Rotation range This contr...

Page 8: ...ntenna position is grossly incorrect you will need to correct it by repositioning the antenna on the mast The complete calibration procedure is the USB RS232 philosophy pdf file for expert only 1 4 The rotator The rotator has a unique design The motor is located on the side of the machine The motor output shaft terminates on a flange where different kinds of mast clamp available from us may be fix...

Page 9: ... 5 must be connected to 5 0 Vdc pot lead GROUND Warning Improper wiring can result in damage to the rotator circuitry when the power is swiched on THIS IS NOT COVERED BY THE WARRANTY 2 4 Rotator cable inspection Ensure the cable is correctly wired before connecting it to the controller Cheking the rotor cable you need a digital multimeter Rotator truth table Pins 1 and 2 DC motor resistence 4 19 o...

Page 10: ...e right resistence valoue 2 7 Rotator installation Before drilling holes in the mounting plate place the rotator inside the tower and adjust its position so there will be no interference between rotator body and tower Put the antenna mast inside the mast clamp and lock centrally The centre axis line must be within 0 5 of true By a pen mark the position of the mounting holes on the mounting place r...

Page 11: ...ents led display are used for the direction indicator and the antenna direction is displayed in degrees A 10 turns 10K potentiometer is used as position reading only 1 turn of the 10 turns is used to read antenna heading See truth table 3 2 2 Motor power switch The motor is powered throught two 10 Amps long life relays DRAW PST61DC working basic block scheme 115V 60Hz 230V 50Hz POWER SUPPLY AC FIL...

Page 12: ... 2 000 600 650 60 yes 500 12 Vdc 5 digital yes yes 14 PST 61D 3 9 3 800 1 180 850 90 yes 500 12 Vdc 5 digital yes yes 25 PST 71D 8 8 6 000 2 172 1 000 120 yes 500 24 Vdc 5 digital yes yes 35 PST 110D 10 6 000 3 400 1 200 150 yes 500 24 Vdc 5 digital yes yes 45 US UK Model Wind area Sq ft Motor Torque Lbs ft Brake torque Lbs ft Vert load Lbs Rotor speed 360 Variable speed Rotation range Motor Volts...

Page 13: ... PC USB port Use such drivers when the PC operating system does not have their own drivers Folder manuals and service documents In this folder you will find a copy of the printed manual and service documents We recommend the reading of each of these Please read it carefully Service issues raised by incorrect use of the software are not covered by the warranty This manual and the files on the CD ar...

Page 14: ... 92 31 CEE 93 68 CEE 93 97 CEE Nr 626 del 25 11 1996 attuazione della direttiva 93 68 CEE Nr 277 del 31 07 1997 modifiche alla Nr 626 del 25 11 96 E conforme ai requisiti di prodotto indicati dalle seguenti norme armonizzate It is conforms to product s requirements as indicate in the following armonized rules CEI EN 50082 1 Compatibilità elettromagnetica norma generica sull immunità Ambienti resid...

Page 15: ... 1 2 ø165mm ø12mm 1 2 ø10mm 3 8 PST2051 5 1 8 ø130mm PST641 4 1 2 ø115mm DRAW Rotor plates holes diagram PRO SIS TEL C da conghia 298 70043 Monopoli BA ITALY www prosistel it Note this drawing is not to scale 15 ...

Page 16: ...w PRO SIS TEL C da Conghia 298 70043 Monopoli BA ITALY tel 39 080 8876607 www prosistel it 280 298 PST2051 PST641 a1 Drawn by Capitanio Piero Scale 1 1 a2 70 80 b1 150 175 b2 90 95 115 d 130 Note measurements in mm Date May 05 2004 Checked by 170 h 186 Rev 16 ...

Page 17: ...L C da Conghia 298 70043 Monopoli BA ITALY tel 39 80 8876607 Draw PST61D general dim Drawn by Capitanio Piero Checked by Rev Scale 1 1 Date Feb 02 2007 Note measurements in mm Fixing plate down view Serial number ...

Page 18: ...Conghia 298 70043 Monopoli BA ITALY tel 39 80 8876607 Serial number Note measurements in mm Draw PST71DC general dimensions Drawn by Capitanio Piero Checked by Date April 09 2008 Scale 1 1 Rev Fixing plate down view 18 ...

Page 19: ...Company Pro Sis Tel Draw PST110D Dimensions Date Sept 03 2010 Rev Note Quotes in millimeters 19 ...

Page 20: ...3 Mast clamps 3 zinc galvanized steel x 2 A4 Split washer ø8mm stainless steel x 6 A5 Bolt stainless steel M8x100mm x 6 A6 Stainless steel nut M8 x 6 A7 Rotator shaft with plate zinc galvanized steel x 1 A8 Split washer ø10mm stainless steel x 4 A9 Nut M10 stainless steel x 4 ...

Page 21: ...ould be damaged from lightning heavy electrostatic charges or electric fields Make sure to disconnect rotator cable from the controller and controller power cord when not used as you do with your coax cables when a tunder storm is approaching Pay attention Protect your equipement because if happens it isn t covered by the warranty ...