background image

1

ST-3500 Series

Installation Guide

Package Contents

(1) ST Unit (1)

(2) English and Japanese Installation Guides 

(one of each) <This Guide>

(3) Warning/Caution Information (1)

(4) Installation Gasket (1) 

 

(Attached to the ST unit)

(5) Installation Fasteners (Set of 4) 

(6) Power Connector (1) 

 

(Attached to the ST unit for DC model)

(7) USB Cable Clamp (1 set)

 

(Holder: 1, Clamp: 1)

This unit has been carefully packed, with 
special attention to quality. However, should 
you find anything damaged or missing, 
please contact your local ST distributor 
immediately.

About the Manual

For the detailed information on ST3000 
series, refer to the following manual.

ST3000 Series Hardware Manual

Maintenance/Troubleshooting

ST3000 Series Hardware Manual can be 
selected from the help menu of GP-Pro EX or 
downloaded from Pro-face Home Page.

URL

http://www.pro-face.com/otasuke/

Caution

Be sure to read the “Warning/Caution 
Information” on the attached sheet before 
using the product.

Summary of Contents for AST-3501T

Page 1: ...carefully packed with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed informati...

Page 2: ...odel Power Input Terminal Block E CF Card Cover F Serial Interface COM1 Dsub 9 pin plug type RS232C is supported G Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is comp...

Page 3: ...ush Current 30A max 60A max Voltage Endurance AC1000V 20mA for 1 minute between charging and FG terminals AC1500V 20mA for 1 minute between charging and FG terminals Insulation Resistance DC500V 10M m...

Page 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Page 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3500 series units with revision code B or later Revision page 12 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Page 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Page 7: ...e the wire is grounded Not ground ing the ST unit will result in excessive noise Use your country s applicable standard for grounding Power Cord Specifications Insertion Slot Recess Hook the fastener...

Page 8: ...ctor Plug Specifications The power connector plug is CA5 DCCNL 01 made by Pro face or GMVSTBW2 5 3 STF 7 62 made by Phoenix Contact When connecting the Power Cord use the following items when performi...

Page 9: ...resistance be sure to twist the ends of the power cord wires before connecting them to the Power con nector Plug The ST unit s power supply cord should not be bundled with or kept close to main circui...

Page 10: ...wire and place it in a duct 5 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possible use a shielded c...

Page 11: ...enclosure The ST unit must be used indoors only Install and operate the ST with its front panel facing outwards If the ST is mounted so as to cool itself naturally be sure to install it in a vertical...

Page 12: ...81 0 6 6613 5888 http www pro face com Copyright 2006 Digital Electronics Corporation All rights reserved 085891J AST3500 MT01E BTH 2007 7 SS F Inquiry Do you have any questions about difficulties wi...