INSTALLATION INSTRUCTIONS

PZM-WW40 -100/277V-RGBW & PZM-WWA40X -100/277V-RGBW

SĒNIK

 A40 & A40X ARRAY RGBW

100-

277V

Prizm

 is a trademark of American Lighting, Inc.  ©2020  www.PrizmLighting.com   REV2038

SAFETY INFORMATION

•  Read all instructions before beginning. Save these instructions for future use.

•  To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this 

manual. Stay within its guidelines when using this product.

•  All units must be unplugged before installing or servicing in any way.

•  Do not route cords or units through walls, doors, windows, or any similar part of a 

building structure.

•  Do not use if there is any damage to the unit, its lens, and/or power cord 

insulation. Inspect periodically.

•  Do not submerge in water or other liquids.

•  Secure unit(s) using mounting hardware appropriate for the mounting surface. Do 

not secure unit or power cord with staples, nails, or other sharp items that may 

damage insulation.

•  As dictated by engineer’s drawings or local code, install safety cables on fixtures.

•  Do not attempt to open or service the fixture. No parts are serviceable by the user.

•  Do not exceed the specified voltage and current input. See Figure 1.

•  This product has a polarized grounded plug as a safety feature to reduce the risk 

of electric shock. Do not cut the plug off or alter it in any way.

•  The operating temperature range of PZM-WWA fixtures is -20°C (-4°F) ~ 45° (113°F).

•  Do not exceed the maximum number of fixtures in any single run. See Figure 1.

•  For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals  

or abrasives.

These products may represent a possible shock or 

fire hazard if improperly installed or attached in any 

way. Products should be installed in accordance with 

these instructions, current electrical codes, and/or the 

current National Electric Code (NEC). 

When using this product outdoors, basic safety 

precautions should always be followed to reduce the 

risk of fire, electric shock and personal injury including 

the following:

•  Ground Fault Circuit Interrupter (GFCI) protection 

should be provided on the circuit(s) or outlet(s) to 

be used for outdoor use. Receptacles are available 

having built-in GFCI protection for this measure of 

safety.

•  Use only outdoor extension cords, such as type 

SEW, SEOW, SEOOW, SOW, SOOW, STW, STOW, 

STOOW, SJEW, SJEOW, SJEOOW, SJTW, SJTOW, or 

SJTOOW. This designation is marked in the wire of 

the extension cord. Never use with an extension cord 

unless plug can be fully inserted. 

WARNING

WARNING

FIGURE 1

Item

PZM-WW40 -100/277V-RGBW

PZM-WW40X -100/277V-RGBW

Input Voltage Range

100-277V AC, 50/60Hz

Max Power

97W (@100V) / 95W (@277V)

162W (@100V) / 160W (@277V)

Power Factor

0.977 (@100V) / 0.81 (@277V)

0.995 (@100V) / 0.93 (@277V)

Input Current

0.994A (@100V) / 0.44A (@277V)

1.64A (@100V) / 0.62A (@277V)

Drive Current

0.2A

0.3A

Max Power Linking

9 Units (@100V) / 20 Units (@277V)

5 Units (@100V) / 14 Units (@277V)

Max Signal Linking

30 Units (using PZM-WW-SIGADAPT-BK)

FIGURE 1

FIGURE 2

Attached mounting 

bracket 

Tilt/Angle

Adjustment

Power + Signal In

Power + Signal Out

BEFORE INSTALLATION:

1.  Familiarize yourself with the dimensions and key aspects of the wall washer. See FIGURE 1.

2.  Determine the number of fixtures to be used and how power will be delivered. Each fixture has a 5pin grounded power and signal  

combination cord which must either be linked to a power + signal splitter (PZM-WW-PSL-15FT for the first wall washer in a series), another wall 

washer fixture, or terminated with a terminator end cap (PZM-WW-SIGEND6PIN). Available accessories (sold separately) include an XLR3 to 

XLR5 adapter (PZM-WW-XLR3-XLR5), a 10ft XLR3 signal extension cable (PZM-WW-XLR3-10-BK), various power jumper cables in 1ft, 

3ft, 6ft, and 20ft lengths (PZM-WW-JUMP#-BK), as well as a signal only linking cable (PZM-WW-SIGADAPT-BK).

3.  Determine mounting method and fasteners required. See FIGURE 2. A pole clamp with safety cable is also available (PZM-WW-PCLMP   

sold separately). 

4.  Determine method of control.

 

Each fixture is factory set to ID = 001. A remote device management (RDM) device is required to address units 

as anything other than 001.

Reviews: