INSTALLATION INSTRUCTIONS
PZM-WW40 -100/277V-RGBW & PZM-WWA40X -100/277V-RGBW
SĒNIK
A40 & A40X ARRAY RGBW
100-
277V
Prizm
™
is a trademark of American Lighting, Inc. ©2020 www.PrizmLighting.com REV2038
SAFETY INFORMATION
• Read all instructions before beginning. Save these instructions for future use.
• To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this
manual. Stay within its guidelines when using this product.
• All units must be unplugged before installing or servicing in any way.
• Do not route cords or units through walls, doors, windows, or any similar part of a
building structure.
• Do not use if there is any damage to the unit, its lens, and/or power cord
insulation. Inspect periodically.
• Do not submerge in water or other liquids.
• Secure unit(s) using mounting hardware appropriate for the mounting surface. Do
not secure unit or power cord with staples, nails, or other sharp items that may
damage insulation.
• As dictated by engineer’s drawings or local code, install safety cables on fixtures.
• Do not attempt to open or service the fixture. No parts are serviceable by the user.
• Do not exceed the specified voltage and current input. See Figure 1.
• This product has a polarized grounded plug as a safety feature to reduce the risk
of electric shock. Do not cut the plug off or alter it in any way.
• The operating temperature range of PZM-WWA fixtures is -20°C (-4°F) ~ 45° (113°F).
• Do not exceed the maximum number of fixtures in any single run. See Figure 1.
• For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals
or abrasives.
These products may represent a possible shock or
fire hazard if improperly installed or attached in any
way. Products should be installed in accordance with
these instructions, current electrical codes, and/or the
current National Electric Code (NEC).
When using this product outdoors, basic safety
precautions should always be followed to reduce the
risk of fire, electric shock and personal injury including
the following:
• Ground Fault Circuit Interrupter (GFCI) protection
should be provided on the circuit(s) or outlet(s) to
be used for outdoor use. Receptacles are available
having built-in GFCI protection for this measure of
safety.
• Use only outdoor extension cords, such as type
SEW, SEOW, SEOOW, SOW, SOOW, STW, STOW,
STOOW, SJEW, SJEOW, SJEOOW, SJTW, SJTOW, or
SJTOOW. This designation is marked in the wire of
the extension cord. Never use with an extension cord
unless plug can be fully inserted.
WARNING
WARNING
FIGURE 1
Item
PZM-WW40 -100/277V-RGBW
PZM-WW40X -100/277V-RGBW
Input Voltage Range
100-277V AC, 50/60Hz
Max Power
97W (@100V) / 95W (@277V)
162W (@100V) / 160W (@277V)
Power Factor
0.977 (@100V) / 0.81 (@277V)
0.995 (@100V) / 0.93 (@277V)
Input Current
0.994A (@100V) / 0.44A (@277V)
1.64A (@100V) / 0.62A (@277V)
Drive Current
0.2A
0.3A
Max Power Linking
9 Units (@100V) / 20 Units (@277V)
5 Units (@100V) / 14 Units (@277V)
Max Signal Linking
30 Units (using PZM-WW-SIGADAPT-BK)
FIGURE 1
FIGURE 2
Attached mounting
bracket
Tilt/Angle
Adjustment
Power + Signal In
Power + Signal Out
BEFORE INSTALLATION:
1. Familiarize yourself with the dimensions and key aspects of the wall washer. See FIGURE 1.
2. Determine the number of fixtures to be used and how power will be delivered. Each fixture has a 5pin grounded power and signal
combination cord which must either be linked to a power + signal splitter (PZM-WW-PSL-15FT for the first wall washer in a series), another wall
washer fixture, or terminated with a terminator end cap (PZM-WW-SIGEND6PIN). Available accessories (sold separately) include an XLR3 to
XLR5 adapter (PZM-WW-XLR3-XLR5), a 10ft XLR3 signal extension cable (PZM-WW-XLR3-10-BK), various power jumper cables in 1ft,
3ft, 6ft, and 20ft lengths (PZM-WW-JUMP#-BK), as well as a signal only linking cable (PZM-WW-SIGADAPT-BK).
3. Determine mounting method and fasteners required. See FIGURE 2. A pole clamp with safety cable is also available (PZM-WW-PCLMP
sold separately).
4. Determine method of control.
Each fixture is factory set to ID = 001. A remote device management (RDM) device is required to address units
as anything other than 001.