background image

OPERATING

INSTRUCTIONS

Dedicated Holding Bin

Model No. DHB2PT-30

DHB4PT-30 & DHB4-30

355 East Kehoe Blvd.   Carol Stream, IL  60188

Tel: (630) 462-8800 

 Fax:  (630) 462-1460

Toll Free:  1-800-PCASTLE

545-502revB 

     

Printed i

n

 USA 1/06 © 2006

This product is warranted to be free from defects in material 
and/or workmanship for a period of 1 year from date of original 
installation, not to exceed 18 months from the date of 
manufacture.
Any component which proves to be faulty in material and/or 
workmanship will be replaced or repaired (at the option of 
Prince Castle, Inc.) without cost to the customer for parts and 
labor. This warranty covers on-location service (i.e. trip 
charges and/or mileage). Travel mileage is limited to 100 miles 
(200 Kilometers) round trip (one trip warranty) from an 
authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
•  Use of any non-genuine Prince Castle parts voids this 

warranty.

•  All labor to be performed during regular work hours. 

Overtime premium (the incremental amount) will be charged 
to the customer.

•  Damage caused by carelessness, neglect and/or abuse 

(e.g., dropping, tampering or altering parts, equipment 
damaged in shipment, by fire, flood or an act of God) is not 
covered under this warranty.

•  All problems due to operation at voltages other than that 

specified on equipment nameplates are not covered by this 
warranty. Conversion to correct voltage is the customer’s 
responsibility.

•  This equipment must be serviced by Prince Castle 

Authorized Service Agency or a Prince Castle Service 
Technician during the warranty period.

LIMITED WARRANTY

TABLE OF CONTENTS

PAGE

Installation ..................................................................... 2
Programming .............................................................. 2-3
Operating ....................................................................... 4
Cleaning ........................................................................ 4
Parts List ....................................................................... 4
Exploded View .............................................................. 5
Troubleshooting ............................................................ 6
Wiring Diagrams ........................................................... 7

ELECTRICAL SPECIFICATION

Model

Volts

  HZ

  Watts   Amps

DHB2-30

208

  60

   1800        8.6

DHB2-30L

120

  60

   1650      13.8

DHB2-30J

200       50/ 60        1650        8.3

DHB2PT-30

208

  60

   1800      8.7

DHB2PT-30L

120          60           1650       13.8

DHB2PT-30J

200

50/60

   1650      8.3

DHB2PT-30CE

220-240   50

   1900        7.9

DHB2PT-30GB

240

  50

   1900      7.9

DHB4PT-30

208

  60

    3600      17.3

DHB4PT-30J

200

50/60

    3400      17.0

DHB4PT-30CE

220-240   50

    3800      16.0

DHB4PT-30GB

240

  50

    3800      16.0

DHB4-30

208

  60

    3600      17.3

DHB4-30J

200

50/60

    3400      17.0

DHB4-30CE

220-240   50

    3800      16.0

DHB4-30GB

240

  50

    3800      16.0

DHB2PT-30

DHB4PT-30

     

DHB4-30 (Non Pass Through)

Summary of Contents for DHB2PT-30

Page 1: ...ged to the customer Damage caused by carelessness neglect and or abuse e g dropping tampering or altering parts equipment damaged in shipment by fire flood or an act of God is not covered under this warranty All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty Conversion to correct voltage is the customer s responsibility This...

Page 2: ... SET POINT The set point temperature is displayed for the selected heaters when this button is pressed during the operating mode The SET POINT LED indicator will be on when the Set point mode is selected Press and hold the Prince Castle button then press and hold the SET POINT button to program the temperature for the selected heater ACTUAL TEMP The actual temperature is displayed for the selected...

Page 3: ...int tempera ture 5 Repeat Steps 1 4 for remaining heaters Programming Timers 1 Press and hold the PROG button for 6 seconds All six timer displays will change to show Prog 2 Press the timer button to change The timer button LED will change to yellow and the current programmed time is displayed 3 Press the UP or DOWN arrow buttons to set the time Time values below 60 minutes will cause the M S led ...

Page 4: ...e press and hold the PROG button then press the UP button Release both button the alarm is set to the high level Press and hold the PROG button then press the DOWN button Release both buttons the alarm is set to the low level CLEANING Caution This bin is not watertight Do not clean with Water Jet Jet Spray Do not immerse the bin with water Caution Before unplugging the power cord make sure the pow...

Page 5: ...1 1 2 2 3 4 5 7 8 9 10 11 12 13 545 502revB 5 Printed in USA 1 06 2006 ...

Page 6: ...e heater probe assembly D Display shows HHH for Temperature is above300 F Diagnostic circuit inoperable Replace an extended period of time abnormal operation Power Circuit Board See B above and heater surface temperature is hot Display shows HHH for Probe is inoperable Check for pinched thermocouple an extended period of time wires from probe Replace heater probe and heater surface assembly temper...

Page 7: ...EL YEL J7 J7 J2 J2 TIMERS 1 6 TIMERS 7 12 SPEAKER SPEAKER CONTROLLER DISPLAY BLU BLU BLU BLU BRN BRN BRN BRN POWER SWITCH POWER CORD GRN YEL THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE J19 YEL J19 BLU 4 3 2 1 4 3 2 1 P3 UPPER A HEATER LOWER A HEATER UPPER b HEATER LOWER b HEATER TC J5 J6 J7 J8 J14 YEL RIBBON CONTROLLER P2 P1 J3 J4 J13 J15...

Reviews: