background image

  

  

Cod:0103082466

Extractors

PRAE0030

Summary of Contents for PRAE0030

Page 1: ...Cod 0103082466 Extractors PRAE0030 ...

Page 2: ...ve had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist Customer Care in the event of a fault with your applia...

Page 3: ...e Under no circumstances should the extractor be connected to any gas ventilation system flue system or hot air ducting system Do not vent the extractor into an attic or loft space Only install the extractor in rooms with adequate ventilation Remember that the extractor is powerful and whatever air is extracted needs to be replaced Do not tile the extractor in It should be removable for service or...

Page 4: ...type of extraction length of ducting room volume ventilation available and cleanliness of the filters Note For best performance you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking This extractor has been designed to be used in a room with a volume of less than 36m ...

Page 5: ...Power Key ...

Page 6: ... the control panel markings by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth The grease filter should be kept clean to minimise the risk of fire At least once a month you should remove the grease filter and clean it with hot soapy water You can also wash the grease filter in a dishwasher ensuring that you place it in an upright position to prev...

Page 7: ...ig 4 When you have released it at the top then you can pull the filter out completely After rinsing and drying reassemble the grease filter to the hood by reversing the removal process Please note Cleaning the grease filter in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance ...

Page 8: ...dours These are included with the cooker hood Attention the cooker hood leaves the factory fitted with a charcoal filter If you wish to use the ducted method please remove the charcoal filter first before attempting to do so Note This charcoal filter is non washable and must be replaced as required To install a new charcoal filter first remove the grease filter as shown in Fig 7 To ensure the best...

Page 9: ...ricity Take out the grease filter and open the black protective cap of the plug in connection from inside Loosen the plug in connection contained therein Carefully loosen the defective LED module downwards and replace the LED Connect the plug in connection and close the external protective cap Connect with power supply again Fig 9 9 Fig 10 Fig 11 ...

Page 10: ...10 ...

Page 11: ...d personnel When installing this product we recommend you seek the help of another individual Electrical Information Mains electrical voltage 230 240Vac Total rated power consumption 112W If your extractor is not working 2 Check that the fuse in the spur has not blown 11 ...

Page 12: ...d be measured from the top of the hotplates or burners Where the extractor is to be installed above a non hob the instructions supplied with the hob may dictate that the height required above the hob is greater than 550mm IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH A GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm The width of any hob must not be greater than...

Page 13: ...13 ...

Page 14: ...NTERNAL WIRING WHICH WILL NOT BE COVERED BY THE WARRANTY Tools required 8 Tools required Fig 14 Mark wall as required see Fig 5 Mark out wall as required see Fig 13 Fig 15 Fig 9 Drill 6 holes for mounting the body Drill six mounting holes Fig 16 Fig 17 Fit wall fixings and top screws Ensure that any fixings you use are appropriate for the wall type 14 ...

Page 15: ...cure the chimney Fig 18 Fit the ducting adaptor Fig 19 Mount the chimney Fig 20 Fig 21 E O E All instructions dimensions and illustrations are provided for guidance only PRIMA reserve the right to change specifications without prior notice 15 ...

Page 16: ...e increase factor f 1 3 FDEHood 19 0 EEIHood 66 8 Measured airflow at Best QBEP 186 5 m3 h Measured Pressure at Best PBEP 326 Pa Maximum airflow QMAX 326 9 m3 h Measured electric power at Best WBEP 89 0 W Nominal lighting power WL 2 0 W Average illumination of the lighting system on the cooking surface EMiddle 94 Lux Measured power consumption in standby PS 0 7 W Measured power consumption PO 0 47...

Page 17: ...12 ...

Reviews: