background image

955692_2 6/13/19

Operator’s Guide – Harvest

For Gen 3 20|20 Displays

Summary of Contents for 20/20 SeedSense

Page 1: ...955692_2 6 13 19 Operator s Guide Harvest For Gen 3 20 20 Displays ...

Page 2: ...est Mode Overview 13 Home Screen Overview 14 Home Screen Tabs 18 Customizing the Home Screen 19 Notification Center 24 Connectivity 24 Speed GPS 24 Cloud Connectivity 26 20 20 Connect 29 Crop Setup 30 Load List Management 31 Setup Button 32 Fields 35 Products 37 Equipment Menu 38 Equipment Profile 38 ...

Page 3: ...ms Menu 42 YieldSense Settings 42 Display General 43 Display Advanced Setup 44 Display Map Layers 45 Display Date Time 45 Display Sound 45 Display Brightness 46 Display About 46 Crops Menu 47 Diagnose 48 YieldSense Level 2 Screens 50 FieldView Info 52 Data 54 Data Export 54 Data Import 55 ...

Page 4: ...955692_2 4 Data Delete 56 Backup Restore 56 Software Update 57 Appendix A 58 Appendix B Harness Layouts 59 ...

Page 5: ...ay provides complete monitoring control and diagnostics for all of Precision Planting s SRM based control products for seed and liquid application down force control and in field sensing in addition to basic planter and combine monitoring The 20 20 has complete control monitoring and diagnostics for vDrive DeltaForce SpeedTube SmartFirmer vDrive Insecticide vApplyHD FlowSense vSet Select mSet Seed...

Page 6: ...o displays can be connected to the Display Base Module at any time If two displays from Precision Planting are used any combination of the two different sizes is acceptable One of these two displays can be an iPad running the Climate Corporation FieldView Cab app Displays can be mounted in any location within the cab ...

Page 7: ...ielded Twisted Pair STP Ethernet Cable to connect to a display If only one display is being used use either port Both ports will be used if connecting to two displays or one display and a FieldView Module FVM The order by which two displays or a single display and FVM are plugged in does not matter ...

Page 8: ...e In Progress Blue CCM Connectivity is Missing N A Nothing Connected Purple Need to Power Cycle System N A FieldView Not Connected Red N A Powering On Powering Up Blinking Red Failure Call Precision Support N A N A Powering the 20 20 On and Off The monitor must have 12 volts of both switched and constant power With the power harness connected to the DBM and power supply turn the key on the tractor...

Page 9: ...d when updates are required for the agreement Note If this system is being set up for a third party the agreement should be reset to appear on next power up for the end user to agree to the document This can be done under Advanced Display settings Refer to the Display section of this manual for more details Note This will only appear on 2019 1 and newer software ...

Page 10: ...a RAM mount Refer to Appendix B and the YieldSense Installation Guides for combine specific harness routing details Step 2 The Display Base Module DBM can be located in any convenient area of the cab Ensure the DBM will not move around when operating the combine Plug one end of the provided Ethernet cord into either port on the front of the DBM and the other end into the back of the display If usi...

Page 11: ...o a standard convenience port An adapter may be required to connect to power and may be included in the YieldSense base kit or purchased separately Note John Deere 9x00 and 9x10 combines will use the power connection integrated into the 751227 Cab Harness Step 4 Connect a Cab Harness into the 12 pin Deutsch Connector on the DBM Refer to the specific combine model s YieldSense Installation Manual f...

Page 12: ...a Radar adapter not used for YieldSense If the installation requires routing a GPS adapter outside of the cab connect the 725155 GPS connection to the Cab Harness to use the external GPS connection Step 6 Connect the OEM CAN harness to the 6 pin Deutsch connector on the DBM if applicable Route the OEM CAN connection to the CAN port Refer to the specific combine model s installation manual for furt...

Page 13: ...isplay software Step 2 Change Implement Type to Combine page 41 Step 3 Configure Combine and Head Setup page 38 Step 4 Select Active Crop page 47 Once the above steps have been completed the system will be ready for operation The Crop Setup must also be completed for accurate yield reporting Refer to the section of this manual on Crop Setup page 30 to complete this procedure ...

Page 14: ...here are three different home screen configurations that can be quickly selected to change the layout of the home screen All three screens are completely customizable with different types of measurements button sizes map sizes control buttons and a minichart Maps The 20 20 displays high definition maps while operating Different map types can be selected and viewed during the harvesting process ...

Page 15: ...adjust settings Change the map orientation by pressing the compass button Switch between two orientation modes North Facing The top of the map is always pointed towards north The combine icon will move around the screen in different directions This is the default orientation mode Indicated by the red compass arrow always pointing towards the top of the screen Implement Facing The implement icon is...

Page 16: ...l of the map 1 Use the Zoom In and Out buttons to change the zoom level of the map 2 Use the standard two finger pinch in pinch out gestures Legends for each map can be toggled on by pressing the On button in the lower left hand corner of the map screen Toggle Legends off by pressing the Off button Most legends can be edited There are two ways to edit legends 1 Hold a finger on the legend and slid...

Page 17: ...to the direction the combine is in Dashboard Mini Chart The Swath Dashboard Mini Chart is located at the bottom of all Home Screens by default The Swath Control bar allows the operator to manually swath off rows on the head from the home screen To use the Swath Control bar press and hold the box representing the row you want to swath off Some boxes have numbers to identify their location on the he...

Page 18: ...he active crop Home Screen Tabs At the very top of the Home Screen are three tabs that change the layout of the Home Screen Each tab can be configured Pressing on a tab active tab is highlighted will change the layout of the home screen This allows different home screen looks to be saved and accessed very quickly Up to eight total layouts can be configured and named The arrows or swiping left righ...

Page 19: ...hat the buttons will fit into The grids overlaying the home screen are used to place buttons such as Metrics Maps and the Dashboard Mini Chart these are all referred to as widgets Every widget takes up a certain about of grid spaces For example a 2 x 2 metric takes up four grid spaces two columns and two rows To remove a widget press the X at the top right corner Press and drag a widget to move it...

Page 20: ...anding the Home Screen Buttons Controls The control buttons are used to control the YieldSense system installed on the combine Control buttons can be displayed in three different sizes Wide 2x1 and Tall 1x2 The Load List and New Load control buttons are set by default on the Standard and Metrics screens Dashboard Minichart Add a Swath Control bar here Once a selection has been made press Apply DMC...

Page 21: ... Once finished press the check mark in the top left corner to save the current layout Note When customizing the home screen only the home screen for the selected tab at the top of the home screen will be changed Customizing the Home Screen To begin the process of customizing the home screen select the button in the top left hand corner of the screen When pressing this button the home screen will b...

Page 22: ...five different sizes Small 1x1 Wide 2x1 Tall 1x2 Large 2x2 Extra Large 3x3 and XXL 4x3 Not all metrics are available in Large and Extra Large Press the size buttons on the right hand side of the screen to view the metrics available in each size Note Definitions for the Metric and Control buttons can be found in Appendix A Understanding the Home Screen Buttons Controls The control buttons are used ...

Page 23: ... a widget that widget will be placed directly in the center of the screen To move the widget press hold drag the widget to the area of the screen for it to be placed at Once the finger is removed from the screen the widget will be placed in that position Note If the widget is placed on top or on top of part of another widget e g the map the entire widget that it was placed on top of will be remove...

Page 24: ...vent Log button will display a list of all notifications from the entire system with the newest at the top This list is permanent so that event codes can be referenced when needed Event codes from just SRMs can be viewed by selecting SRM on the navigation pane Select individual event codes to view additional details and recommendations for fixing the issue Connectivity Speed GPS Speed The top righ...

Page 25: ...ving For best GPS results Set the Baud Rate to 19200 or 38400 in the system ouputting the GPS The communication Quality should be as close to 100 as possible There should be at least three satellites within view The HDOP should be between 0 2 Set NMEA messages GGA RMC or ZDA and VTG at 5 Hz in the system outputting the GPS Additional NMEA messages may degrade the GPS information due to too much in...

Page 26: ...mum GPS quality percentage for mapping to occur Primary Packet This setting will allow for the user to switch between GGA and RMC for the primary NMEA packet Note Do not change any of the GPS correction settings unless instructed to do so by a Dealer or Product Support GPS Nudge GPS nudge can be used to move the map data in situations where GPS shift has occurred Use the 1 buttons to nudge the map...

Page 27: ...ble networks Use the Disconnect button at the bottom of the page to leave the active network Once the network has been joined a WiFi symbol will appear in the GPS button This symbol will also indicate the strength of the network signal While WiFi is connected background imagery can be viewed on the home screen The background map style can be changed at the bottom of the Cloud Connection Page Once ...

Page 28: ...rd Note WiFi must be connected prior to logging in to properly authenticate your login information Once the system has authenticated your cloud login information a white cloud symbol will appear in the GPS button A red cloud indicates that the cloud is not currently connected Cloud Backup Once the 20 20 Cloud is connected change the Cloud Backup toggle to Enabled The Cloud Uploaded percentage will...

Page 29: ...onnects locally to the on board DBM WiFi This app can be used for Calibrations Health Checks and other system controls Once the app has been downloaded follow the on screen instructions to pair it to your device For more information on 20 20 Connect and how to use it refer to the 20 20 Connect Operator s Guide ...

Page 30: ...2 Once at least 25 000 lbs is harvested press Next then Actual LBS on the screen to enter the actual weight Step 3 After entering the actual weight Press Enter to save the crop calibration Note If this is the first crop setup that has been completed for the year the crop constant will be applied retroactively to all the fields harvested of the same crop for that year ...

Page 31: ...d can also be re activated by pressing on that load and selecting Make Active Loads True Up A loads true up will calculate a new crop constant for the active field This crop constant will continue to be applied to the yield until a new crop constant is calculated through a new loads true up It is recommended to have at least three loads or 25 000 lbs harvested prior to performing a loads true up E...

Page 32: ...d A Displays the active field name as well as the total acres planted for the field in the current season Press on the field name to select a different field name B Diagnostic Information Displays the diagnostic color from the diagnose page C D Hybrid Information A color will be assigned to each row indicating the hybrid name that is assigned Colors correspond to the hybrids listed underneath the ...

Page 33: ...92_2 33 When navigating through different screens there will always be a Back button that will navigate the user to the previously viewed page The Home button will navigate the user to the main home screen ...

Page 34: ... as well as the monitor Crops Edit the active crop as well as the crop constant grain shrink information and yield units Diagnose The primary location for troubleshooting issues related to the operation of the display and products being controlled monitored on the combine Data Export Import and delete data into the monitor as well as updating software Note More information for each of these menus ...

Page 35: ...ng Setup on the home screen Selecting the active field name on the setup page will direct to the same page When the Fields menu is selected the Active Field name will be displayed with a green heading Also the Client and Farm name of the Active field will be shown At the bottom of the screen other fields for the same Client and Farm name will be shown To access the Field Setup screen for the activ...

Page 36: ...o view all Field names under the selected Client Farm name The Field Setup screen will appear when a Field name has been selected including the active field name Select Make Active to make the selected field active so data and maps are stored under the field name If the large button says Done then the selected field is already the active field A field name can be deleted by selecting the Delete Fi...

Page 37: ...tup and select Add Crop To enter the hybrid information from the dashboard select Active Hybrid To add a new hybrid select Add Hybrid from database for selecting a hybrid from the AgX database Or select Add custom hybrid to manually type a hybrid name in If Add hybrid from database was selected Use the on screen keyboard to search for the name of the product Select the appropriate name when it is ...

Page 38: ...tly in the Equipment Pages Equipment Profile Press the Combine Make button Select the appropriate make of the combine Choosing the Combine Make will define some of the choices available in later selection screens Press the Combine Series button Select the appropriate series of the combine Press the Combine Model button Select the appropriate model of the combine ...

Page 39: ...option Wide Silver or Narrow Black refers to the moisture sensor size and color Select the moisture sensor color size that is installed Fixed Moisture Value Select this option for a fixed value Combine Measurements GPS offset measurements must be set up prior to harvesting in order for the monitor to correctly model the combine From the home screen select Setup Equipment Combine Measurements A Ent...

Page 40: ...d B Enter the distance between the center line of the combine and the center line of the head If it is off center select either Measure to Left or Measure to Right C Enter either row width Row Head or harvestable width Platform Head Number of Rows Swath Sections Enter the number of rows on the head Row Head or the number of swath section the head will be divided into Platform Head Harvesting Heigh...

Page 41: ...guration can then be deleted updated with future changes or loaded to change to that configuration Implement Type The Gen3 20 20 has different implement modes that can be enabled These modes include Planters Combines Air Seeders and Sidedress Bars To switch modes select Setup Equipment Implement Type Note Use the Save Load option in the equipment menu to save the Tractor Implement Combine and Head...

Page 42: ...ass between when the grain leaves the elevator and hits the moisture sensor Grain Moisture Positive Negative Offset This allows you to calibrate your moisture sensor to a certified moisture sensor Change the offset as necessary until the moisture sensor values match your samples First adjust moisture on your combine display or your AgLeader display If a moisture offset is entered on the combine di...

Page 43: ...f the Grain Property Kit is installed then this setting must be Enabled in order for the system to use the information gathered from it Note The Grain Property Kit is not installed on any John Deere 94XX 95XX and Lexion 6 chain systems This should be set to disabled on these systems Crud Brush If the crud brush has been removed or damaged and is not working properly then this setting should be dis...

Page 44: ...en provided from a Precision Planting representative for a specific support issue it must be entered in this location Demo Mode Enables the demo mode which will display planting or harvest data on the display A demo file is required for this to mode to function Press on this button to Enable demo mode Touch Screen Test Tests to see if all areas of the touch screen work correctly When in the test t...

Page 45: ...r the Time enter the time in the standard 0 23 hour clock Display Sound Select the Sound option in the navigation pane when in the Display menu to configure the sound settings The volume can be controlled using the volume sliders below each sound type Selecting each sound type allows the selection of different sound options If a sound option is selected a demo will play If no sound is desired for ...

Page 46: ...htness for day night Select Manual to display a slider bar to manually adjust the brightness Display About View software versions and serial numbers for both the Display and the Display Base Module Press on the software versions to be directed to the Software Update Screen Serial Numbers cannot be manually entered but will automatically update when plugged into a Display and Display Base Module Th...

Page 47: ...lations Note If a custom crop is created this setting will have Small Medium or Large Grain available Select the grain size that best fits the active crop Date The date of the most recent Crop Constant change including any field and load true ups Measured The Measured weight of the original crop setup Actual The actual weight entered by user of the original crop setup Constant This is the current ...

Page 48: ...e has failed or is expected but not detected White Device is detected but is not expected Black System has been disabled in the configuration Gray Device is being detected updating firmware or unreachable All systems should be Green before using the system in the field The color of each system on the top level diagnose page will be reflected by any issues within the system For example if there is ...

Page 49: ...er from the most recent event to the oldest event with the newest event codes at the top of the list All events will have a number and a date time when the event happened along with a description of the event Select any event code to view additional details for that specific code Advanced Logs Allows for a detailed log to be Enabled Exported and Deleted To begin a detailed log press the Enable Det...

Page 50: ...Crud Build Up Missing Broken Paddle Flow Rate NH Frequency Elevator Frequency Crud Brush Force Flow Coefficient Missing Property Bucket Channel A and B Voltage and Diagnostic information OEM CAN The OEM CAN button on the diagnose page is showing the CAN information we are receiving from the combine It includes the following Connected Model Moisture Feed House angle Seperator Engine RPM Wheel Speed...

Page 51: ... A and B Voltage Motor Status Motor State Grain Present Proximity Sensor Voltage Detected Harness YSM The YSM YieldSense Module is what processes all of the information for the YieldSense system In the YSM tab on the diagnose screen it includes the following Connected Communication Quality Fw Version Active tooth count Detected tooth count YSM crop type Display Machine Config YSM Machine Config YS...

Page 52: ...enabled or disabled For this to work shared swath must be enabled on all 20 20s in the field Config Changes This setting changes the ability for configuration changes to be accepted from the FieldView platform can be enabled or disabled including all settings changes such as Client Farm Field Prescriptions This setting choice will be prompted the first time a FieldView Module is plugged into the 2...

Page 53: ...ommunicating with the FVM The FieldView Username displays the username that the 20 20 is linked to This username is saved when an operator selects Yes this is my 20 20 on the FieldView Cab app Sharing swath between equipment in a field can also be toggled between enabled or disabled For this to work shared swath must be enabled on all 20 20s in the field ...

Page 54: ...tive field s swath coverage map This map can then be imported into another display so that the second implement swaths off to the original implement s coverage map Equipment Config Exports the active implement type e g planter combine or seeder and seeding liquid insecticide settings to a USB Drive After selecting Equipment Config enter a name for the configuration This is done to separate configu...

Page 55: ...er display or placed directly onto the root directory on the USB drive Field and Crop Config Import Client Farm and Field names as well as the crop and hybrid configurations from another 20 20 or a Generation 1 2 20 20 SeedSense monitor Prescription Boundary Imports prescription and boundary files from a USB Drive Files must be in the form of Shape Files and include the shp shx and dbf file extens...

Page 56: ... be filtered by Season or by the type of field pass at the top of the screen Select an individual field multiple fields or all fields to delete the data This does not delete the Client Farm Field name for the field Prescription and Boundary Files Displays a list of all shape files imported into the display and recorded on the 20 20 Select either individual multiple or all files to be deleted All D...

Page 57: ...up Restore Config Restore just the configurations to the 20 20 Equipment Configurations Display Configurations and Field Crop Configurations Software Update Select the Software Update button on the navigation tab to change the software version on the Display Base Module and Display Install from USB Software can be downloaded for free from the Precision Planting website and saved to a USB drive Ens...

Page 58: ...r the active load The values are Yield Moisture Acres Lbs Flow and Bushels Note Loads will not show until the crop setup is complete Flow Grain flow across the Flow Sensor measured in pounds per second Lbs wet The total mass of grain harvested Yield wet Wet weight divided by acres harvested Bushels Dry weight divided by crop pounds per bushel If dry weight is less than nominal moisture for a crop ...

Page 59: ...nsor External GPS Connection 12V Power Connection John Deere 50 60 70 S YieldSense Electrical System Overview Flow Sensor 751150 Analog Primary Analog Secondary PP OEMCAN Power DBM Power Harness 725150 Radar Connection Not Used for Harvest Cab Harness 751200 CAN Connection and Plug Not Used Internal GPS Connection Connect together if using the external GPS connection GPS Radar Gen3 725155 ...

Page 60: ...r Radar Connection Not Used for Harvest Cab Harness CAN Connection and Plug Not Used Gen3 YieldSense Module YSM2 Secondary YSM Base Harness 750819 Aux Ground Speed Elevator Speed Head Height Internal GPS Connection Connect together if using the external GPS connection Power 15Amp Fuse Power Harness 750841 JD Bulkhead Harness 751228 JD 9X00 10 Cab Harness 751227 GPS Radar Gen3 725155 Aux Connection...

Page 61: ... Flow Sensor 750527 Analog Primary Analog Secondary PP OEMCAN Power DBM Power Harness 725150 Internal GPS Connection Radar Connection Not Used for Harvest Cab Harness 751203 CAN Connection and Plug Not Used Cab Power Harness Adapter 750529 Only required on pre 2013 machines Relay Connect together if using the external GPS connection Aux Connection Used for Analog Moisture Sensor GPS Radar Gen3 725...

Page 62: ...51161 Analog Primary Analog Secondary PP OEMCAN Power DBM Power Harness 725150 Internal GPS Connection Radar Connection Not Used for Harvest Cab Harness 751203 CAN Connection and Plug Not Used Cab Power Harness Adapter 750771 Relay Connect together if using the external GPS connection Gen3 YieldSense Module YSM2 751131 Aux Connection Used for Analog Moisture Sensor GPS Radar Gen3 725155 ...

Page 63: ...DBM Power Harness 725150 Internal GPS Connection Radar Connection Not Used for Harvest Cab Harness 751203 CAN Connection and Plug Not Used Cab Power Harness Adapter 750771 Relay Connect together if using the external GPS connection Gen3 YieldSense Module YSM2 751131 Secondary YSM Base Harness 750819 Aux Ground Speed Elevator Speed Head Height Aux Connection Used for Analog Moisture Sensor GPS Rada...

Page 64: ...trical System Overview Analog Primary Analog Secondary PP OEMCAN Power DBM Power Harness 725150 Radar Connection Not Used for Harvest CAN Connection and Plug Not Used 3 Pin Power Adapter 725719 Internal GPS Connection Connect together if using the external GPS connection Cab Harness 751203 Flow Sensor 751164 Aux Connection Used for Analog Moisture Sensor GPS Radar Gen3 725155 ...

Page 65: ...em Overview Flow Sensor 751164 9 751153 6 Analog Primary Analog Secondary PP OEMCAN Power DBM Power Harness 725150 Radar Connection Not Used for Harvest CAN Connection and Plug Not Used Internal GPS Connection Connect together if using the external GPS connection Cab Harness 751203 Lexion 400 500 Power Adapter 751226 Aux Connection Used for Analog Moisture Sensor GPS Radar Gen3 725155 ...

Reviews: