background image

INFRARED BEAM PHOTOCELL FT12/FT20-AV

English

The Photocell Kit Consists of:
1 No. Photocell Receiver
1 No. Photocell Transmitter
1 No. Fixing Kit
1 No. Set of fitting instructions

INSTALLATION

Transmitter

Insert the cables in the special seat and make the connections
according to the type of application, 12 or 24V~ or V

, synchronized

or not synchronized.
-Adjust the cable within the unit to eliminate any surplus.
-Fix the unit.
-Seal the cover & cable entry to prevent insect infestation.

Receiver

Operational Verification

Red led Function:

-Insert the cables into the special seat and make the connections according to the type of application chosen for the transmitter,
12/24V~ or V

, synchronized or not synchronized.

-Adjust the cable within the unit to eliminate any surplus.
-Make sure that the receiver is in frontal position, lined up on the same axis and in the same height of the associated transmitter. Act
on the lens adjustment if necessary (see fig.6-7).
-Seal the cover & cable entry to prevent insect infestation.
Once executed the preceding operations for both Tx and for Rx:
-Power supply the photocells 12-24V~ or V

and verify their alignment. If the positioning, the alignment and the connection of the

photocells are correct, the red LED on the receiver will be switched on.

Fit one of the black plastic photocell covers complete with an opaque diffuser label stuck across the lens.
- Check that the relay works correctly.
- Check that the red led goes out when the beam is broken.

The FT12/FT20-AV device cannot be used as security  device (EN 12978).

The photocell FT12/FT20-AV has been projected to be used exclusivley as photoelectric barrier to be installed in the areas
considered dangerous and in proximity of the gate/ leaf.

Please dispose of this product packaging in a responsible, appropriate way.

The FT12/FT20-AV photocell conforms to the following: 2004/108/CE (Act on the Electromagnetic Compatibility)

(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes

at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of
where and how they can take this item for environmentally safe recycling.

When being transported this product must be properly packaged and handled with care

Cleaning and maintenance of this unit must be carried out at 6 monthly intervals by authorised, qualified personnel. During routine

Please note: For the syncronized function, the power supply has to be necessarily of 12/24 V~ (alternating current).

RED LED LIT: ALIGNED

SECURITY

INTENDED USE

ENVIRONMENT

CONFORMITIES

Correct Disposal of This Product (Waste Electrical & Electronic Equipment) - Europe only

STORING

CLEANING AND MAINTENANCE

Pag. 1

STORAGE TEMPERATURES

T

min

T

max

Humidity

min

Humidity

max

-20 °C

+70 °C

5% no condensation

90% no condensation

Rev. 01 - 12/02/2017

Caractéristiques techniques

Nominal range :           FT12=12m   FT20-AV=20m
Signal:                          infrarouge modulé
Wave length :               880 nm
Modulation fréquency:  1000 Hz
Supply voltage:            12 - 24 V      / V~
Absorption current:       30 mA TX; 30 mA RX
Temp. operating range -15 °C / + 60°C
Relay contact tating:

1A max @ 24V

Humidity:                      de 5 % à 90 % no condens.
Dimensions                  129 X 48 X 42 mm
IP

55

Summary of Contents for FT12

Page 1: ...dangerous and in proximity of the gate leaf Please dispose of this product packaging in a responsible appropriate way The FT12 FT20 AV photocell conforms to the following 2004 108 CE Act on the Electromagnetic Compatibility Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not ...

Page 2: ... and to cross the power supply Ex When the TX and RX of a photocell are power supplied with a black cable around 0 V and with a red cable of 24V the TX and the RX of the other photocell will have to have the red cable with 0 V and the black cable around 24V JP1 ON JP1 OFF SYNCRONIZATIONACTIVATED SYNCRONIZATION NOTACTIVATED Rev 01 12 02 2017 Fig 4 Fig 3 The fixing screw A positioned on the front ho...

Page 3: ... FT12 FT20 AV ne peut pas être utilisé comme dispositif de sécurité EN 12978 Le dispositif FT12 FT20 AV a été étudié pour l utilisation exclusive comme barrière infrarouge à disposer dans les zones dangereuses et en proximité du portail vantail Ne pas disperser dans l environnement les matériaux de l emballage et ou les circuits Le dispositif FT12 FT20 AV est conforme aux normes 2004 108 CE Direct...

Page 4: ...photocellule sont alimentés avec un câble de couleur noire de 0 V et avec un câble de couleur rouge de 24V le TX et RX de l autre photocellule devront avoir le câble de couleur rouge à 0 V et le câble de couleur noire à 24 V de 12 24 V et de croiser les alimentations JP1 ON SYNCHRONISATION ACTIVE JP1 OFF SYNCHRONISATION INACTIVE Rev 01 12 02 2017 Fig 4 Fonctionnement avec positionnement pas aligné...

Reviews: