DRAWING

CODE

WEIGHT

VOLUME

REV

REV.

DATA

DESCRIPTION

AUTHOR

01

-

  -

-

02

-

  -

-

03

-

  -

-

04

-

  -

-

A1 Format - 841 x 594

POWERSOFT S.p.A.

Via E.Conti, 5 - 50018 Scandicci (FI) - Italy

Tel. +39 055 7350230 - fax +39 055 7356235

http://www.powersoft.it

(      )

3.2

0.8

Note: -

-

19/10/2018

1:2

lombardi

1 / 1

M-Force

00

22589,7 g

4886,9 cm^3

.

M-Force

.
.

.
M-Force

265

298

236

100

100

25

25

100

27

7

28

6

111

±0

,5

127

±0

,5

55

M-Force Engine Kit

DO000252.00 Rev 0

Moving Magnet Linear Motor Transducer 

for low frequency applications

M-Force 01 (PF000399) and M-Force 02 (PF000327) versions

Summary of Contents for M-Force 01

Page 1: ...WITHOUT OUR PERMISSION DRAWING CODE WEIGHT VOLUME REV REV DATA DESCRIPTION AUTHOR 01 02 03 04 A1 Format 841 x 594 POWERSOFT S p A Via E Conti 5 50018 Scandicci FI Italy Tel 39 055 7350230 fax 39 055...

Page 2: ...DO000252_powersoft_MForceEK_UG_EN Data are subject to change without notice For latest update please refer to the online version available on www powersoft audio com...

Page 3: ...s to the cabinet 4 4 2 Fasten the motor to the brackets 4 4 3 Plug the motor to the amplifier 5 4 4 Verify the alignment of the diaphragm 5 4 4 1 Troubleshooting the mechanical alignment 6 4 5 Diaphra...

Page 4: ...has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING TO REDUCE THE RISK OF ELECTRIC SHOC...

Page 5: ...elque mani re que ce soit par exemple si le cordon d alimentation ou sa fiche sont endommag s si du liquide ou tout autre corps tranger a p n tr dans l appareil si l appareil a t expos la pluie ou l h...

Page 6: ...como por ejemplo si el cable de alimentaci n o el enchufe est n da ados se ha vertido l quido o se ha ca do alg n objeto dentro del aparato o bien si dicho aparato ha sido expuesto a la lluvia o a hum...

Page 7: ...guasti dell apparecchio quali danneggiamento del cavo di alimentazione o della spina versamento di liquidi o caduta di oggetti nell apparecchio es posizione a pioggia o umidit o se l apparecchio non...

Page 8: ...Page intentionally left blank...

Page 9: ...viron ment high power efficiency high thermal inertia low usage of Neodymium at equal SPL in comparison to conventional design are distinctive features of the Powersoft s Green Audio philosophy 2 2 Un...

Page 10: ...2 M Force Engine Kit User guide Mechanical Drawings 3 M Force 01 02 Engine Kits 100 100 236 265 298 25 25 100 277 286 55 111 0 5 127 0 5 277 286 55 111 0 5 127 0 5...

Page 11: ...Mechanical Drawings 3 FIGURE 1 Main assembly M Force 01 02 Engine Kit...

Page 12: ...CK ACCORDING WITH THE LAW WE RESERVE THE PROPERTY OF THIS DRAWING IT CANNOT BE REPRODUCED OR OTHERWISE MAKE KNOW TO OTHER COMPANIES OR COMPETITORS WITHOUT OUR PERMISSION PROJECT CODE DRAWING CODE E ma...

Page 13: ...ignment of the diaphragm Place the diaphragm into the cabinet and take care that it fits the baffle cutout and perfectly lies on its the surface No room must be left between the diaphragm an the surfa...

Page 14: ...n move the engine Place w on t Place washers nuts on the hub weak mechanical connection Bad axial alignment 37 1 mm 37 1 mm wrong rest position move the engine Place w on Place washers nuts on the hub...

Page 15: ...Installation instructions 7 4 5 Diaphragm bay design tollerance 30 W 4 mm PE HWU diaphragm PF30FP00 175 1 8 5 0 5 717 1 717 1 18 6 0 24 12 0 11 2 5 O 732 0 5 8 5 0 5 O 762 0 5...

Page 16: ...8 M Force Engine Kit User guide 30 V 4 mm PE HWU diaphragm PF30SP00 405 2 24 12 0 18 6 0 717 1 717 1 8 5 0 5 11 2 5 O 732 0 5 8 5 0 5 O 762 0 5...

Page 17: ...Installation instructions 9 40 W 4 mm PE HWU diaphragm PF40FP00 917 1 917 1 175 u 1 24 12 0 18 6 0 8 5 0 5 10 O 932 0 5 O 8 5 0 5 O 962 0 5...

Page 18: ...sur rounding environment an issue As any other traditional transducer it is highly recom mended to favor the ventilation of the motor of the M Force taking advantage of the air flow by the diaphragm...

Page 19: ...t you may build your own cables out of 12 AWG wire 4 crimp on terminals and a 4 pole housing Reported below are the part numbers f f MOLEX 42816 0412 HOUSING 10mm 4P 1ROW 50A f f MOLEX 42815 0114 CRIM...

Page 20: ...ss 23 N s m Motor strength Bl 2 Re 2215 T m 2 Maximum acceleration 3800 m s2 Mechanical Electrical Thermal parameters Type Push Pull Moving Magnet Linear Motor Nominal Size H x W x L 280 mm x 266 mm x...