background image

 

AG1500S QUICK START GUIDE 

1. Power Requirement 

Your AG1500S has a power limit of 1500W. Please ensure that the power draw of connected 
equipment does not exceed this. Note that the AG1500S is not meant to be operated at a 1500W 
continuous load. It is designed for typical Hi-Fi fluctuating loads which may peak at 1500W. 

2. Installation 

 

Place the AG1500S in an area with adequate air flow to the front and to the rear of the unit. 

 

The unit should be mounted horizontally. To avoid any scratches stick on rubber feet have 
been provided as an option. To use peel the backing off the feet and stick on to the underside 
of the unit close to the corners. 

 

The unit can be mounted in a 19

” rack. The unit should be placed on a shelf or rack rails. 

Rack ears have been provided to enable the unit to be secured. To fit, remove the 2xM4 
screws on both sides of the unit and fit the rack ears as shown. 

 

 

Remove M4 screws highlighted (2 each 

side) 

Fit Rack Ear 

 

3. Connections 

 

 

With the mains lead provided connect from your wall socket outlet to the AC Input connection 

 on the rear of the AG1500S. 

 

Connect your equipment to the IEC connections on the rear panel. There is 1xC19 outlet 

 

and 6xC13 outlets 

. All outlets are connected internally. 

 

The DC input connection 

 is used to connect an external battery pack for UPS operation 

and is not required in normal use. 

 

The USB port 

 is used to monitor the AG1500S with a computer using the software 

provided. It is not necessary for operation of the AG1500S. 

 

 

A rewireable C20 plug has been provided for convenience for 
use with the C19 outlet. Please consult a competent person to 
wire this if required. The plug has 3 terminals marked: 

o

 

– for the Live conductor usually coloured brown; 

o

 

–for the Neutral conductor usually coloured blue; 

o

 

E or

 

for the protective earth conductor, usually 

coloured Green and Yellow. 

 

 

 