background image

 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Medium Voltage Variable Speed Drive 

 

Commissioning Procedure 

Checklist

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Edition: December 2011 

XMV66FPM001AI Rev. A 

 
 
 
 

Summary of Contents for XMV660 Series

Page 1: ...Medium Voltage Variable Speed Drive Commissioning Procedure Checklist Edition December 2011 XMV66FPM001AI Rev A ...

Page 2: ...d to this product please contact our website www power electronics com ALARM SECURITY WARNING This symbol indicates the presence of potential hazard which may result in serious personal injury when instructions are omitted or not followed properly CAUTION Identifies shock hazards under certain conditions Particular attention should be given due to the presence of dangerous voltage Maintenance oper...

Page 3: ... 3 E N G L I S H REVISION CONTROL Date Revision Description 21 12 2011 A First edition The equipment and technical documentation is periodically updated Power electronics reserves the right to modify all or part of the contents within the manual without previous notice ...

Page 4: ...IREMENTS AND VISUAL INSPECTION 10 1 1 Requirements 10 1 2 Visual Inspection 10 2 DEBUGGING MODE 12 2 1 Local control HMI Debugging test 12 2 2 Remote control debugging test 12 2 3 Communication control debugging test 13 3 MEDIUM VOLTAGE COMMISSIONING 14 3 1 Unloaded motor 14 3 2 Loaded motor 14 ...

Page 5: ...POWER ELECTRONICS XMV660 MEDIUM VOLTAGE SPEED DRIVE SAFETY INSTRUCTIONS 5 E N G L I S H ...

Page 6: ...mon and important ones have been pointed out The installer should follow the instructions described within the getting started manual provide quality electric work and localise all of the recommendations and warnings provided before starting the equipment Make sure the drive is completely disconnected from the power supply and earth grounded before any use or maintenance operation is carried out I...

Page 7: ...ble surface Keep away from flammable materials Otherwise fire risk existence Install the equipment in a ventilating and clean place Otherwise accident and fire risk existence Disconnect the input voltage 20 min in advance and ensure that there is no voltage in any cell before carrying out inspection or maintenance operations Otherwise electric shock hazard existence Disconnect and earth ground the...

Page 8: ...ould be damaged POWER FACTOR COMPENSATION The reactive compensation capacitors used to increase the power factor should be connected to the drive input terminals and not to the output ones These capacitors should be connected with an additional contactor The connection will be done only when the drive is not running Otherwise the drive can be damaged GROUND CONNECTIONS The driver locker chassis mu...

Page 9: ...eration of the input power grid the optimal grid isolation and connection and the optimal grounding If the output isolation value is measured the medium voltage drive should be disconnected 1 2 Visual inspection It is mandatory to carry out a completed visual inspection of all the Medium voltage drive compartments previous commissioning The following tasks are necessary TASK STATUS Check that the ...

Page 10: ...er cells are correctly installed and fixed Verify the correct operation of the power cell fuses measuring its terminals impedance Verify that the impedance between the input phases L1 L2 L3 and ground is greater than 100kΩ Verify that the impedance between the output phases U V W and ground is greater than 100kΩ The fans are correctly installed and rotates smoothly without noise Check that the out...

Page 11: ... Ref Frequency Press Frequency up button and check that the system frequency increase Press Frequency down button and check that the system frequency decrease Press the HMI Stop Button and check how the frequency decreases down to zero Press again the HMI Start button to restart the system Press the HMI Emergency Stop check how the frequency decrease down to zero and the fault appears in the scree...

Page 12: ...LOW VOLTAGE TEST 2 3 Communication control debugging test TASK STATUS Select the remote control mode on the cabinet selector Simulate a remote start and stop through the communication ports Simulate a remote frequency control through the communication ports ...

Page 13: ...e circuit breaker of the fans and check that are working without noise or vibration and the rotation direction is correct Start up the motor with the load uncoupled Verify the motor rotation direction and DCS operations 3 2 Loaded motor Once the unloaded motor start up has finished correctly the qualified technician will open the circuit breaker and the switch and he will connect the grounds Next ...

Page 14: ......

Page 15: ...l 49 911 99 43 99 0 Fax 49 911 99 43 99 8 AUSTRALIA Power Electronics Australia Pty Ltd U6 30 34 Octal St Yatala BRISBANE QUEENSLAND 4207 P O Box 6022 Yatala DC Yatala Qld 4207 AUSTRALIA Tel 61 7 3386 1993 Fax 55 11 5891 3769 BRAZIL Power Electronics Brazil Ltda Av Guido Caloi 1985 Galpão 09 CEP 05802 140 SÃO PAULO BRASIL Tel 55 11 5891 9612 Tel 55 11 5891 9762 CHILE Power Electronics Chile Ltda L...

Reviews: