Stainless Steel Pizza Salad Prep/Saladette Counter

G604 - Pizza/Salad Prep Counter
G605 - Pizza/Salad Prep Counter

G606 - Saladette Counter
G607 - Saladette Counter

Model:

Summary of Contents for G604

Page 1: ...Stainless Steel Pizza Salad Prep Saladette Counter G604 Pizza Salad Prep Counter G605 Pizza Salad Prep Counter G606 Saladette Counter G607 Saladette Counter Model ...

Page 2: ...lves Floor Guides 1 Operation 1 Storing Food 1 Turn On 1 Open Close the Lid G606 G607 Only 1 Control Panel 2 Lock Unlock the Control Panel 2 Enter the Parameter Menu 2 Manual Defrost 3 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Disposal 4 Compliance 4 ...

Page 3: ...ackaging Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces 2 Maintain a distance of 20cm 7 inches between the unit and walls or other objects for ventilation Increase this distance if the obstacle is a heat source Fitting the Shelves Floor Guides 1 Place one set of shelf guides on either side of the cabinet at the desired height 2 Slide the shelf into...

Page 4: ...uration can be overridden by parameter d10 below if the cut off temperature is reached before the end of the defrost duration 0 999 minutes d10 Defrost Cut off Temperature Set the defrost cut off temperature 45 C to 50 C d11 Additional Cut off Defrost Period Set an additional amount of defrost time after the defrost cut off point has been reached if required 0 99 minutes d12 Delayed Actual Tempera...

Page 5: ...le Cause Action The appliance is not working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperature is too high low Too muc...

Page 6: ...ergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approved to carry the following symbol Error Message flashing Cause Appliance Response Action HtA The inner temperature exceeds the set maximum temperature Display flashes Alternating error message and current temperature Ch...

Page 7: ...Notes ...

Page 8: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...