Summary of Contents for H1KL

Page 1: ...1 H series online UPS LCD 1 3KS L U U Us s se e er r r s s s m m ma a an n nu u ua a al l l PDF pdfFactory Pro www fineprint cn...

Page 2: ...o people Don t open the battery or do the battery damage for the liquid spilled from battery is strongly poisonous and do harmful to body Please avoid short circuit between battery anode and cathode o...

Page 3: ...8 2 1 Unpacking and inspection 9 2 2 Safety notes 9 2 3 The description of front panel and display lamp 10 2 4 UPS input connection 11 2 5 UPS output connection 12 2 6 External battery connection 13...

Page 4: ...ass seamlessly and provide alarm Advanced voltage compensation technology makes the wide input voltage range reducing the battery usage enhancing the adaptive ability against the bad mains power varia...

Page 5: ...nating current from the utility power to direct current This direct current charges the batteries and powers the inverter On the basis of this DC voltage the inverter generates a pure sinusoidal AC vo...

Page 6: ...UPS Alternating current source AC Direct current source DC Protective ground Alarm silence Overload indication Battery check Recyclable Do not dispose with ordinary trash 1 4 Appearance Front display...

Page 7: ...7 H2 3KS rear panel EXT BATTERY COMPUTER INTERFACE INTELLIGENT SLOT BREAKER NETWO RK FAX M ODEM SUGERPROTECTION OUT IN OUTPUT FAN INPUT OUT IN H1KL rear panel PDF pdfFactory Pro www fineprint cn...

Page 8: ...erage maximum 12A 20A 30A Power rating 1KVA 0 7KW 2KVA 1 4KW 3KVA 2 1KW Voltage 220VAC 2 Output Frequency 50 60Hz 0 2 Batteries Number and type 3 12V7AH None 8 12V7AH None 8 12V7AH None 1 5 2 Dimensio...

Page 9: ...ing the model number on back panel of the equipment 2 2 Safety notes 1 Keep good air circulation around UPS and far away from water flammable gas and corrosive 2 Don t place UPS on the slope and there...

Page 10: ...l continuously for 1 second Press the OFF button on the front panel continuously for 1 second to turn off the UPS Bypass LED orange LED whenever the bypass LED is turned on it shows that the loading c...

Page 11: ...the items of the second row item section orderly Press and hold for some time circularly and orderly display the items from INPUT BATTERY OUTPUT LOAD TEMPERATURE every 2 seconds When you press and ho...

Page 12: ...rectly plug the load cable into the output socket 2 Output of H2KS L and H3KS L not only provide socket but also offer high currency output wiring socket which make output wiring become easy UPS model...

Page 13: ...abnormal or be damaged Battery voltage for H1KL is 36VDC for H2KL is 96VDC for H3KL is 96VDC 2 One end of external battery cable is connected to UPS the other end is open style two cables used to conn...

Page 14: ...r 3 Once turned on the UPS will perform a self test function when the green LED lights on LCD status figure shows block LINE and INV and BATTERY that means UPS is working in utility mode 3 1 2 Start u...

Page 15: ...he buzzer stops beeping if you press and hold the FUNCTION button for 1 second and it will restart to beep if you press and hold the ON OFF button for one more second Off charging model When utility i...

Page 16: ...ult and need to be replaced You can press the FUNCTION button for 1 second to do the manual self test for more details please refer to the troubleshooting table 3 2 2 Battery mode On battery mode the...

Page 17: ...as following Fault mode Red LED is on The digital section indicates the fault code For more details please refer to the abnormal process table 3 2 4 Backup time for the standard model The backup time...

Page 18: ...cal distributor for further information RS232 Interface The following are the descriptions and pin assignment of RS232 DB 9 port Baud rate 2400bps Data bit 8 bit Ending bit 1 bit Parity bit none DB 9...

Page 19: ...and over discharging l The UPS should be charged once every 4 to 6 months if it has not been used for a long tine l In the regions of hot climates the battery should be charged and discharged every 2...

Page 20: ...area The charge time of standard units must be more than twelve hours 1 If it is necessary to replace any connection cables please purchase the original materials from the authorized distributors or s...

Page 21: ...hooting The following messages are the messages that users would find on UPS when it meets some problem with the use of such messages users can know where the problems are and how to deal with such pr...

Page 22: ...No and the serial No of the UPS The date when the problem arose Complete description of the problem including the LED display alarm warning and power condition and load capacity If your UPS is a long...

Page 23: ...23 information Appendix EMC grade standards H series UPS are manufactured according to the following EMC international grade standard PDF pdfFactory Pro www fineprint cn...